Sign up today for our Gold Plan, now only $299/yr! (was $339)

Austin TX Heating & Air Conditioning Services

Expert HVAC Service in Austin TX

Since 1988, residents of Austin, TX have trusted Garner Heating & Air Conditioning to provide professional work and outstanding service for all of their HVAC needs. If you're looking for a provider you can count on, call today!

How much does it cost to replace an AC line near Austin TX?

It costs around $200-$400 to replace an AC line in Austin, TX. The cost of the replacement can vary depending on: 

  • The cost of the AC line.
  • If other parts also need to be replaced.
  • The contractor’s hourly rate. 

AC lines can be fairly inexpensive to replace, but the overall cost can increase if you need to have other components replaced along with the AC line. To get your AC line replaced, contact us today. 

Should I repair or replace my home air conditioner near Austin TX?

A few reasons you may want to replace your home air conditioner rather than repair it in Austin, TX include: 

  • Your air conditioner is over 10 years old. 
  • Your air conditioner breaks down often. 
  • Your air conditioner does not cool you home effectively. 

Another reason you may want to replace your home air conditioner rather than repair it is if the cost to repair it is more than half of the cost to replace it. A newer and more efficient unit will be able to run smoother and cost you less on energy each month. To get your home air conditioner replaced, call us today. 

Does a higher SEER rating on my home air conditioner cool better?

If your home air conditioner has a higher SEER rating, it can cool your home more efficiently than other systems. Since the higher SEER rating can make your air conditioner more efficient, it will also typically cost you less on energy costs each month. Although, you should ensure that your air conditioner’s SEER rating matches your specific needs to ensure that it is able to work its most efficiently in your area's climate. To learn more about what SEER rating your air conditioner should have, give us a call today. 

How much does AC repair cost in Austin TX?

To repair an AC unit in the Austin, TX area, you can expect to pay between $350 - $800 on average. This cost varies depending on what needs to be fixed. Most repairs are minor fixes, and average around $350. Major repairs, such as complicated refrigerant leaks or compressor replacements, can top $2,500.

Average Cost: $350
Typical Range: $350 - $800

At Garner Heating & Air, we provide reliable honest AC repair services at affordable prices. Contact us online today for more information or to get on our schedule.

How do I fix my AC refrigerant leak near Austin TX?

A trained technician should be called to fix a refrigerant leak. You can’t just add refrigerant to a system like you would oil to a car for a few reasons:

  • Refrigerant is a dangerous thing to work with and can be hazardous if you do not have the proper experience and equipment.
  • Leaks need to be repaired correctly as refrigerant can be harmful to the environment if spilled.
  • The amount of refrigerant in the system needs to match the manufacturer’s recommendation exactly or the unit will not perform to its best ability.

A technician will be able to accurately diagnose where the leak is, whether they can solder the pipe or have to replace the coils and the precise amount of refrigerant to add to correctly charge the system.

Why is my air conditioner running but not cooling the house?

There could be a few reasons your air conditioner is running but not cooling the house. Before you call an AC repair company, there are some measures you can take that may solve the problem:

  • Turn the thermostat to AUTO if it was set to ON - When turned to the ON setting, the blower will run continuously even when the unit is not producing cool air. Setting the system to AUTO allows the unit to cycle the way it was built to and recharge.
  • Change the air filter - If the filter is dirty, it might be clogging the system so air cannot circulate properly. When airflow is blocked, this could cause the system to struggle to cool the home.
  • Clean the outdoor unit - When the condenser is dirty, the warm air the unit is trying to expel cannot get out and will circulate back inside.
  • Check the circuit breaker - Make sure the breaker to the outside unit has not tripped. If the breaker has tripped, the unit will keep blowing air into the house without cooling it first. If it keeps tripping a professional will need to be called.

If you have checked these items and your unit is still not cooling the house, call the experts at Garner for repair services. We can diagnose any AC issue and fix it effectively at an affordable rate. Contact us online today for an appointment.

If you'd like to know what your neighbors in Austin, TX think, just check out their reviews below!

Recent Jobs and Reviews in Austin, TX

Rated 4.9 out of 5 stars based on 78 customer reviews

Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting high levels of customer satisfaction and appreciation. Customers consistently express gratitude for the professionalism, punctuality, and expertise demonstrated by the service team. There is a strong recurring theme of technicians being knowledgeable, thorough, and excellent communicators who take time to explain issues, answer questions, and provide helpful advice without applying undue pressure. Many reviewers highlight the courteous and respectful nature of the staff, noting details such as wearing shoe covers, protecting work areas, and leaving spaces clean after completion. Timeliness emerges as another dominant positive trend, with numerous mentions of technicians arriving on time or even early, completing work efficiently, and providing same-day service. Customers frequently express confidence in the quality of work performed, even under challenging conditions like extreme heat, and many indicate strong loyalty, stating they will use the service again and recommend it to family and friends. The emotional tone is enthusiastic and appreciative, with reviewers describing their experiences as "great," "excellent," "fantastic," and "outstanding." Overall, the reviews convey a sense of trust, reliability, and exceptional customer care that has clearly resonated with clients.

Austin, TX at a glance

Garner Heating & Air Conditioning Inc has completed 25 jobs in Austin, TX between July 2023 and November 2023.

The most recent job was on November 17, 2023.

Garner Heating & Air Conditioning Inc has completed 74 jobs in Austin, TX in the last 12 months. The first job there was in July 2018.

Job Locations and Reviews

Elijah D.
Elijah D. Checked in
Performed semiannual maintenance on one comfort heating system. Inspected all Performance, Mechanical and Safety Systems. Adjusted fuel pressure to match the furnace’s rated output to ensure 100% heating capacity. Verified all systems were operating within manufacture’s specifications for operation.
Austin, TX 78745
Omar H.
Omar H. Checked in
Performed maintenance on one furnace system. Checked all electrical, mechanical and performance of the system. I found the outdoor capacitor under value on the compressor side. No other major issues found. I presented my findings to the homeowner, and he chose to have the capacitor replaced today. Repair completed and the system is on at this time.
Austin, TX 78747
Omar H.
Omar H. Checked in
Performed heating maintenance on one furnace system. Checked all electrical, mechanical and performance of the system. I found the blower motor capacitor under value. No other major issues found. I presented my findings to the homeowner, and she chose to have the capacitor replaced today. I replaced the capacitor and cycled power. System is on at this time.
Austin, TX 78748
Omar H.
Omar H. Checked in
Performed heating maintenance on two heat pump systems. Checked all electrical, mechanical and performance of the systems. I installed an ionizer on each system and verified that the ionizers are on and working.
Austin, TX 78737
Brendan B.
Brendan B. Checked in
Performed heat check. Checked electrical, mechanical, safety, and performance of the system. Flame ignition achieved and flame sensor cleaned. Filter changed by customer before arrival. No major issues were found and system operational at time of departure.
Austin, TX 78736
Brendan B.
Brendan B. Checked in
Performed heat check. Checked electrical, mechanical, safety, and performance of the system. Flame ignition achieved and flame sensor cleaned. Filter was changed prior to my arrival. No major issues were found and system running at time of departure.
Austin, TX 78737
Ethan D.
Ethan D. Checked in
Completed upstairs system re-duct with new buckets, flex and supply grilles. Replaced plenums on both systems and installed Aprilaire media filters on both. Replaced plenum triangles with wyes for downstairs system. Replaced downstairs bucket and flex that goes to the playroom.
Austin, TX 78749
Ethan D.
Ethan D. Checked in
Replaced 12” crossover duct. Cleared and verified drain operation. Checked system pressures and capacitor readings. Verified system operation.
Austin, TX 78748
Elijah D.
Elijah D. Checked in
On arrival, I found the emergency water safety switch tripped due to a restricted drain line. I cleared the primary drain line. I then went to the exterior drain exit located behind the condensing unit and was able to visually verify the drain blockage was removed from the line. Placed a drain treatment inside the primary line and pan and reset the cooling system. Inspected all Performance, Mechanical and Safety Systems. Verified the system was cooling and operational prior to departure. Everything is working at this time.
Austin, TX 78748
Elijah D.
Elijah D. Checked in
On arrival, I found the outdoor system attempting to power up but would not fully turn on. Inspected the outdoor run capacitor and found it has failed below value across all terminals. Installed a new run capacitor and reset the cooling system. Inspected all Performance, Mechanical and Safety Systems. Verified everything was operating within manufacture’s specifications for operation. Everything is working at this time.
Austin, TX 78748
Isaiah M.
Isaiah M. Checked in
Performed the AC tune-up. Cleared and treated drain line. Condenser coil clean. I did find two failing dual capacitors. No other major issues found. Presented repair options and the homeowner chose to have both capacitors replaced today. Completed repair and the system is operational.
Austin, TX 78736
Ethan D.
Ethan D. Checked in
Replaced Indoor Thermal Expansion Valve. Installed the Stage 3 Breathe Easy package. Rebuilt the primary and secondary drain. Cleared the drain and treated it. Pressure tested with nitrogen and pulled a vacuum on the copper line set. We then verified system operation and verified system charge was to manufacturers specifications.
Austin, TX 78744
Matt F.
Matt F. Checked in
Performed AC cool check. Checked electrical, mechanical, safety, and performance of the system. No major issues were found. Drain line cleared and treated. Condenser coil cleaned. Electrical disconnect confirmed in and on. System was running at the time of departure.
Austin, TX 78749
Elijah D.
Elijah D. Checked in
On arrival, I found the drain line clogged. I spoke with the homeowner regarding how his two drain lines work and where they are routed to. Informed homeowner how to treat the drain line on a regular basis when he changes the filter. Said he is going to purchase a CO2 drain line cleaner to also do when he changes his filters. I did go ahead and blow out both primary and secondary drain lines and flush with water to ensure proper drain flow. Also removed all drain build up from the primary pan inside the air handler. Reset the cooling system and ensured caps were placed back onto the drain lines. Everything is working at this time.
Austin, TX 78748
Brendan B.
Brendan B. Checked in
Performed semiannual maintenance on one cooling system. Inspected all Performance, Mechanical and Safety Systems. Verified everything was operating within the manufacture’s specifications for operation. Indoor system drain line cleared and treated. Filter was already changed by homeowner before arrival. Outdoor condenser refrigerant pressures are within range and condenser cleaned. No major issues were found, and the system is running at time of departure.
Austin, TX 78747
Matt F.
Matt F. Checked in
Performed service diagnostic. Diagnostic found that the capacitor on the condenser unit has failed. Options for repair were presented to the customer and they chose to have the capacitor replaced today. Capacitor was replaced and the system was function checked. System was running at the time of departure.
Austin, TX 78737
Brendan B.
Brendan B. Checked in
Performed semiannual maintenance on two cooling systems. Inspected all Performance, Mechanical and Safety Systems. Verified everything was operating within the manufacture’s specifications for operation. Both indoor systems’ drain lines cleared and treated and filters changed. Indoor blower motors on both systems have a buildup of dirt. Outdoor system condensers’ refrigerant pressures are within range. Condensers are extremely caked with dirt and consumed by vines. Took unit apart and cleaned coils. No other major issues found.
Austin, TX 78739
Ethan D.
Ethan D. Checked in
Installed new 2-ton Carrier gas system. Installed new Ecobee thermostat. Installed new supply and return air plenums and sealed with mastic air lock. Replaced secondary drain pan. Rebuilt and insulated condensate drain. Installed return air filter grille in upstairs office. Replaced disconnect and whip at outdoor system. Installed a new liquid line filter dryer, pressure tested system with dry nitrogen and pulled a vacuum on the copper line set. Charged system to factory specifications. System is working properly at time of departure.
Austin, TX 78739
Elijah D.
Elijah D. Checked in
Living Room HVAC System: On arrival I inspected the outdoor system, and I noticed the outdoor contactor starter sputtering from a low voltage issue. I noticed the low voltage control wiring to be cut up and arching between wires at the exterior penetration of the UV shielding. I removed the failed wiring and spliced in new control wiring. I then ran the wire in Liquid-Tite tubing to help protect against the elements and any animal that may chew on the wiring. I secured wiring into the outdoor unit and installed new wiring terminal connections.
Austin, TX 78739
Matt F.
Matt F. Checked in
Performed service diagnostic. Diagnostic found that the capacitor on the condenser unit has failed. Options for repair were presented to the customer and they chose to have the capacitor replaced today and join our maintenance plan. Capacitor was replaced and the system was functioning checked. System was running at the time of departure. We will return in Fall/Winter to complete first of two maintenance visits.
Austin, TX 78737
Jason D.
Jason D. Checked in
Replaced the TXV. Replaced the inline filter dryer, pressure tested with dry nitrogen and pulled a vacuum on copper line set. Charged system to fac Specs and checked operation of the system. Everything is working properly at this time.
Austin, TX 78748
Marissa I.
Marissa I. Checked in
Performed the AC tune-up. Cleared and treated the drain line. Condenser coil clean. I did find that the blower wheel was extremely dirty restricting airflow. No other major issues found. The homeowner decided to move forward with repairs. Pulled and cleaned blower wheel and housing. System operational.
Austin, TX 78737
Elijah D.
Elijah D. Checked in
On arrival, I found the indoor coil freezing over and noticed ice on the suction line up in the attic. I also noticed the indoor blower motor was not running. I took off the blower door panel, hooked up my ECM tester and confirmed the motor has failed. I did verify that the system and motor are getting the proper 120v per design. Recommended having a new OEM blower motor installed to ensure system returns back to 100% cooling capacity. Installed new replacement OEM motor and verified system startup. Verified all Performance, Mechanical and Safety Systems are operating within manufacture’s specifications for operation. Everything is working at this time.
Austin, TX 78747
Brendan B.
Brendan B. Checked in
Performed semiannual maintenance on one cooling system. Inspected all Performance, Mechanical and Safety Systems. Verified everything was operating within the manufacture’s specifications for operation. Outside condenser refrigerant pressures are within range and condenser cleaned. Indoor system drain line was clogged so I cleared it a few times and added a drain treatment. No other major issues were found, and the system was running at time of departure.
Austin, TX 78748
Brendan B.
Brendan B. Checked in
Performed semiannual maintenance on two cooling systems. Inspected all Performance, Mechanical and Safety Systems. Verified everything was operating within the manufacture’s specifications for operation. Outside units’ refrigerant pressures are within range and condensers cleaned. The east side unit’s indoor system drain line was clogged so I cleared it. The west side indoor system drain line was also cleared with no issues. Filter changed. No other major issues found. Systems operational upon completion of service.
Austin, TX 78748
Kyle . Buda . San Marcos . Wimberley . Driftwood . Martindale . Manchaca . Lockhart . New Braunfels
Schedule Now Text Us Now
Award Winning Service
  • Google Guaranteed
  • Carrier Authorized Dealer Logo
  • Service Round Table Member Logo
  • Best Or North Hays Logo
  • Nate Certified Technicians Logo
  • National Comfort Institute Inc Logo