Expert HVAC Service in Dripping Springs TX
Since 1988, residents of Dripping Springs, TX have trusted Garner Heating & Air Conditioning to provide professional work and outstanding service for all of their HVAC needs. If you're looking for a provider you can count on, call today!
Some of the symptoms of bad indoor air quality in your Dripping Springs home are:
- Dry throat, nose and eyes.
- Dry or irritated skin.
- Increased allergies indoors.
Bad indoor air quality can also cause your home issues, such as mold growth, due to excessive humidity levels. To find out more about improving the indoor air quality of your home, contact us today.
It costs around $350-$3500 to repair a home air conditioner in Dripping Springs. Some things that can cause the price of the repair to vary include:
- How extensive the repair is.
- What type of repair is required.
- Whether replacement parts are needed.
Some repairs can be fairly inexpensive, whereas refrigerant leaks can be expensive due to the cost to replace the refrigerant in your AC system. To get your home air conditioner repaired, call us today.
Yes, AC tune ups are worth it in Dripping Springs. Some of the benefits of having your AC unit tuned up are:
- Your AC unit runs more smoothly.
- Your AC unit uses less energy.
- Your AC unit breaks down less.
Another benefit to having your air conditioner tuned up is that it will require less repairs and cool your home better. To get the best results, you should have your AC unit tuned up at least once a year. To get your AC unit tuned up, give us a call today!
There could be a number of issues with your air conditioner that is causing it to blow hot air in your home near Dripping Springs TX. Try troubleshooting a few common reasons first before calling a technician:
- Turn the thermostat to AUTO if it was set to ON so that the unit can complete a full cooling cycle.
- Change the air filter in order for the air to be able to circulate properly throughout your home.
- Clean the outdoor unit so that the unit can expel warm air from your home.
- Check the circuit breaker in case it has tripped which will cause it to still operate but not produce cool air.
If you have checked these items and your unit is still not cooling the house, your next step should be a call to a professional. The expert technicians at Garner can diagnose any AC repair issue and fix it effectively at an affordable rate. Contact us online today for an appointment.
On average, in the Dripping Springs TX area you can expect to pay anywhere from $250 - $1,500 to a freon leak repair. It can be hard to estimate the cost of a freon leak in an air conditioner as the price depends almost entirely on where the leak is located and the size of it. A hard to find severe leak could take technicians all day to repair, which will increase costs of labor.
For a more accurate estimate on repair services, the knowledgeable team members at Garner are happy to help. Contact us today to learn more about freon leaks and their costs!
An AC compressor works to move refrigerant throughout the unit to ultimately produce the cool air for your home. When it goes bad, there are a few signs you should be on the lookout for:
- Weird noises.
- Unit will not start.
- Air is not cooling.
- Breaker keeps tripping.
- Less air coming from vents.
Do you suspect your compressor is going bad? Contact Garner today for precise reliable AC repair services!
If you'd like to know what your neighbors in Dripping Springs, TX think, just check out their reviews below!
Local Reviews
for Dripping Springs, TX
Our Reviews by City
Awesome service!
Kim - Dripping Springs, TX 78620
Brendan Baker provided great service! He was professional, friendly and able to explain what needed to be completed very well. He is an excellent asset to your company! Would definitely recommend Garner’s and Brendan Baker! Thanks!
Dripping SpringsTX78620 30.26-98.095



Outstanding Service!
Penne - Dripping Springs, TX 78620
Omar is a true professional. He arrived on time and was conscientious about keeping his shoes covered when he entered the house and procured all work services promptly. He showed us the options we had to keep our system in peek condition which we could choose to do or not with no pressure. We’ve been using Garner’s services for over a decade and they never let us down. Omar is a wonderful addition to this successful and trustworthy business.
Dripping SpringsTX78620 30.1925-98.1625



AC Repair
Roland - Dripping Springs, TX 78620
As always excellent service. Arrived on time diagnosed the problem and had me up and going in no time.
Dripping SpringsTX78620 30.215-98.135



Excellent service
Roland - Dripping Springs, TX 78620
Dripping SpringsTX78620 30.215-98.135




AC repair
Merz - Dripping Springs, TX 78620
AC went down Friday evening. The technician was out early the next morning to repair unit. Technician very informative found the problem gave me a quote upon my approval repaired it right then. He was very friendly and courteous. Recommend Garner Heating and AC.
Dripping SpringsTX78620 30.215-98.135



Great service
Merz - Dripping Springs, TX 78620
Dripping SpringsTX78620 30.215-98.135




Always great service
Gonzales - Dripping Springs, TX 78620
All employees are polite and know what they're doing.
Dripping SpringsTX78620 30.25-98.065



Don came out here by 130 on a1to5 window. Great service, knowledgeable and professional. Will recommend your company.
Paul - Dripping Springs, TX 78620
Dripping SpringsTX78620 30.21-98.2125




Awesome service as always!
Penne - Dripping Springs, TX 78620
We are so glad we take advantage of the maintenance package offered. The technicians are always professional and courteous. It’s much appreciated sharing the work done and knowing how our units are performing as well as what to expect in the future with our aging units. Thank you!
Dripping SpringsTX78620 30.1925-98.1625




Matt F.
Performed service diagnostic. Diagnostic found that the condensate drain line was clogged. Water had back up and tripped the safety switch. Options for repair were presented to the customer and they chose to have a drain service completed today and sign up for our semiannual maintenance plan. The first of two visits will be completed this Fall/Winter. Drain line was cleared and flow tested with water. Drain line was treated. System was function checked and was running at the time of departure.
Marissa G.
Performed service diagnostic. Diagnostic found that the capacitor on the condenser unit was depleted and couldn’t reliably start the compressor. Options for repair were presented to the customer and they chose to have the capacitor replaced today. Capacitor was replaced and the system was function checked. System was running at the time of departure.
Isaiah T.
Performed two AC tune-ups. Cleared and treated drain lines. Condenser coils clean. No major issues found.
Isaiah T.
Performed an AC tune-up. Cleared and treated the drain line. Condenser coil clean. No major issues were found.
Omar H.
Air Conditioning System Repair. Performed diagnostic. I found that the outdoor capacitor (80/7.5) has failed. I presented the customer with options to repair and he chose to have it replaced at this time. I replaced it with a 70/7.5 and added a 10 mfd capacitor to the herm side. Confirmed both zones are open, and system is operational at this time.
Brendan B.
Air Conditioning System Maintenance Service. Performed semiannual maintenance on two cooling systems. Inspected all Performance, Mechanical, and Safety Systems. Verified everything was operating within the manufacturer’s specifications for operation. Outdoor condenser refrigerant pressures are within range and condensers clean. Indoor system drain lines cleared and treated. Filters are dirty, but the homeowner did not have replacements. I advised them to replace them ASAP. I noticed that the westside unit’s condenser fan motor is showing signs of overheating. We have added UV lights to the downstairs unit but not the upstairs unit. No other major issues found. I recommend that we replace the fan motor and add UV lights to the upstairs system. The homeowner would like to have the fan motor replaced today but did not want to add UV lights at this time. Fan motor replaced and both systems are operational.
Elijah D.
On arrival, I found the water safety switch tripped due to a restricted drain line. I blew out the drain line and flushed and treated the drain line with two gallons of water. Verified drains were properly flowing and verified the water safety switch was clear prior to departure. Everything is working at this time.
Elijah D.
Found the outdoor run capacitor has failed below value across all terminals. Installed new run capacitor and remade the electrical termination terminals. Reset the cooling system and verified operation. Inspected supply air temperature and verified system was operating with a 18° temperature split. Everything is working at this time.

Ethan D.
On arrival, the homeowner informed me that the upstairs system was failing to keep up with the thermostat setpoint throughout the day. He said this issue has never happened before in the past and the system has worked good previously. I turned the inverter system to max stage and performed a complete system checkout. I noticed my suction line pressure was well below design specs and my suction line temperature was running warm. I opened up the evaporator coil panel and found that the coil was beginning to frost over. I verified appropriate airflow of the system and verified there were no air flow restrictions of the system. After further diagnostics, I was able to pinpoint the cooling issue to an indoor metering device failure. The metering device is stuck closed and will not allow any refrigerant to pass through into the coil. I tested the metering device by adjusting the heat pump valve on the outdoor unit, which confirmed the issue. It is recommended that we replace the indoor
Elijah D.
Found the outdoor run capacitor failed. Installed new run capacitor and verified system operation. Supply vent had a 66° temperature. Return was 84° temperature. System is operating at this time. Informed homeowner that the system would be running for some time due to the interior house temp.
Omar H.
Performed cooling maintenance on two systems. Cleared and treated both drain lines and washed both condenser coils. I found the blower wheel on the guest room system is dirty. No other major issues found I replaced the blower wheel for the system on the north side of the house (AH2). Cycled the thermostat. Everything is operational at this time

Matt F.
Performed AC cool check on two systems. Checked electrical, mechanical, safety, and performance of the system. Capacitor for the downstairs condenser unit is below value. No other major issues were found. Drain lines cleared and treated. Condenser coils cleaned. Options for repair were presented to the customer and they chose to have the capacitor replaced today. Repair was completed. System was function checked and was running at the time of departure

Matt F.
Performed AC cool check. Checked electrical, mechanical, safety, and performance of the system. No major issues were found. Drain line cleared and treated. Condenser coil cleaned. Electrical disconnect confirmed in and on. System was running at the time of departure.
Omar H.
Performed cooling maintenance on two AC systems. Cleared and treated both drain lines and washed both condenser coils. I found both systems have small amounts of dirt and mold in the blower wheel and around the air handler. I wiped it off as best as I could and offered the customer options to repair; she declined at this time. I also found the filters are dirty, but the customer didn’t have any replacement filters for me to change out today. She said she will replace the filters as soon as she is able to purchase some. No other major issues were found. Both systems are on and running at this time.
Elijah D.
On arrival, I found the hard start capacitor failed, not allowing the outdoor compressor to turn on and pump refrigerant throughout the indoor cooling coils. I installed a new hard start assist and tested system. I continued my diagnostic and found the refrigerant levels to be low which caused a drastic reduction in cooling capacity. Spoke with homeowner, he said he would just like to have the system recharged with refrigerant today. I added in R-22 to get the system back up to spec. Verified system was cooling upon departure. Everything is working at this time.
Brendan B.
Performed semiannual maintenance on two cooling systems. Inspected all Performance, Mechanical and Safety Systems. Verified everything was operating within the manufacture’s specifications for operation. Outdoor condenser refrigerant pressures for both systems are within range and condensers cleaned. Indoor system drain lines cleared and treated. Filters checked. No major issues were found. Systems running at time of departure.

Matt F.
Performed AC cool check. Checked electrical, mechanical, safety, and performance of the system. No major issues were found. Drain line cleared and treated. Condenser coil clean. Electrical disconnect confirmed in and on. System was running at the time of departure.

Ethan D.
Trip 1 - Performed heat check. Checked electrical, mechanical, safety, and performance of the system. Condenser fan motor shows signs of overheating and is leaking grease. Capacitor on the condenser unit is below value. The evaporator coil and air handler are dirty. Mold and mildew are on both the coil and pan, along with some on the wiring harness for the blower fan. Blower fan is dirty. Return for the system is dirty and in need of cleaning. The filter for the unit is not the correct size due to not being a Honeywell filter. The housing for the filter has separated from the air handler due to items piled onto the indoor unit and will need to be sealed. The return for the system needs sealing as well. The return plenum above the return vent/grate has gaps that need to be sealed. System sterilizers will need to be installed as well due to the mold. Options for repair were presented to the customer and they chose to move forward with all repairs. Once parts are received, our office w
Elijah D.
Diagnosed faulty outdoor condenser fan motor on downstairs system. Spoke with homeowner and they chose to move forward with the repair. Could not order today due to the holiday but need to call Aces and order motor when they reopen on Tuesday. Ordered motor and it will be shipped directly to our office. Will return once received to complete repair. Installed new outdoor condenser exhaust motor and completed performance and safety testing. System operational.
Elijah D.
Performed semiannual maintenance on two heat pump heating systems. Inspected all Performance, Mechanical and Safety Systems. Verified all heating operations. On the upstairs system, the condenser fan motor is running outside the manufactures specifications for operation. Customer declined repairs at this time. Please see attached checklists for full tune-up details.
Elijah D.
Performed semiannual maintenance on two heat pump heating systems. Inspected all Performance, Mechanical and Safety Systems. Found microbial growth along the coil and control wiring in the system that services the downstairs portion of the home (located in the garage). Also noted on the outdoor heat pump that the fan motor has overheated but is still operational. Spoke with Mr. and Mrs. Christman and we decided to move forward with installing our Stage 3 Breathe Easy Ultra-Violet lights. Breathe Easy Stage 3 was installed and tested. On the system that services the master bedroom and upstairs (zoned system), I found everything to be operational and clean within the manufacture’s specifications for operation. Changed two Honeywell F100 filters supplied by homeowner. Please see attached checklists for full tune-up details.
Elijah D.
Performing semiannual maintenance on two heat pump and two gas furnace systems. Inspected all Performance, Mechanical and Safety Systems. Adjusted the LP pressure to the gas furnace to allow for proper Low & High Stage Heating. Inspected the outdoor inverter system, checked and verified refrigerant levels, and changed two homeowner supplied filters inside the filter base located in attic. Flushed and treated the primary drain line and cycled system to verify operation upon departing. Did note the upstairs cooling system to be low on charge. Recharged system back to manufacture’s specifications for operation and had a 9.1°SC and a 13°SH.
Elijah D.
Inspected all Performance, Mechanical and Safety Systems. Did find the indoor blower motor to have failed. Verified all control voltages and high voltages to unit. Also noted large amounts of microbial growth and dust inside the indoor air handler. Recommend replacement of the indoor motor and installing 3-Zone UV Lights to treat air passing through system. Installed new indoor OEM blower motor and UV lights. Tested all systems and everything is working at this time.
Elijah D.
Performed semiannual maintenance on one cooling system. Inspected all Performance, Mechanical and Safety Systems. Found everything to be operating within manufacture’s specifications for operation.

Matt F.
Performed AC cool check on two systems. Checked electrical, mechanical, safety, and performance of the systems. Reme Halo on the system for the main house was not operational. Unit is receiving power but unit has failed. No other major issues were found. Drain lines cleared and treated. Condenser coil cleaned. Electrical disconnect confirmed in and on. System was running at the time of departure.