Sign up today for our Gold Plan, now only $299/yr! (was $339)

Austin TX Heating & Air Conditioning Services

Expert HVAC Service in Austin TX

Since 1988, residents of Austin, TX have trusted Garner Heating & Air Conditioning to provide professional work and outstanding service for all of their HVAC needs. If you're looking for a provider you can count on, call today!

How much does it cost to replace an AC line near Austin TX?

It costs around $200-$400 to replace an AC line in Austin, TX. The cost of the replacement can vary depending on: 

  • The cost of the AC line.
  • If other parts also need to be replaced.
  • The contractor’s hourly rate. 

AC lines can be fairly inexpensive to replace, but the overall cost can increase if you need to have other components replaced along with the AC line. To get your AC line replaced, contact us today. 

Should I repair or replace my home air conditioner near Austin TX?

A few reasons you may want to replace your home air conditioner rather than repair it in Austin, TX include: 

  • Your air conditioner is over 10 years old. 
  • Your air conditioner breaks down often. 
  • Your air conditioner does not cool you home effectively. 

Another reason you may want to replace your home air conditioner rather than repair it is if the cost to repair it is more than half of the cost to replace it. A newer and more efficient unit will be able to run smoother and cost you less on energy each month. To get your home air conditioner replaced, call us today. 

Does a higher SEER rating on my home air conditioner cool better?

If your home air conditioner has a higher SEER rating, it can cool your home more efficiently than other systems. Since the higher SEER rating can make your air conditioner more efficient, it will also typically cost you less on energy costs each month. Although, you should ensure that your air conditioner’s SEER rating matches your specific needs to ensure that it is able to work its most efficiently in your area's climate. To learn more about what SEER rating your air conditioner should have, give us a call today. 

How much does AC repair cost in Austin TX?

To repair an AC unit in the Austin, TX area, you can expect to pay between $350 - $800 on average. This cost varies depending on what needs to be fixed. Most repairs are minor fixes, and average around $350. Major repairs, such as complicated refrigerant leaks or compressor replacements, can top $2,500.

Average Cost: $350
Typical Range: $350 - $800

At Garner Heating & Air, we provide reliable honest AC repair services at affordable prices. Contact us online today for more information or to get on our schedule.

How do I fix my AC refrigerant leak near Austin TX?

A trained technician should be called to fix a refrigerant leak. You can’t just add refrigerant to a system like you would oil to a car for a few reasons:

  • Refrigerant is a dangerous thing to work with and can be hazardous if you do not have the proper experience and equipment.
  • Leaks need to be repaired correctly as refrigerant can be harmful to the environment if spilled.
  • The amount of refrigerant in the system needs to match the manufacturer’s recommendation exactly or the unit will not perform to its best ability.

A technician will be able to accurately diagnose where the leak is, whether they can solder the pipe or have to replace the coils and the precise amount of refrigerant to add to correctly charge the system.

Why is my air conditioner running but not cooling the house?

There could be a few reasons your air conditioner is running but not cooling the house. Before you call an AC repair company, there are some measures you can take that may solve the problem:

  • Turn the thermostat to AUTO if it was set to ON - When turned to the ON setting, the blower will run continuously even when the unit is not producing cool air. Setting the system to AUTO allows the unit to cycle the way it was built to and recharge.
  • Change the air filter - If the filter is dirty, it might be clogging the system so air cannot circulate properly. When airflow is blocked, this could cause the system to struggle to cool the home.
  • Clean the outdoor unit - When the condenser is dirty, the warm air the unit is trying to expel cannot get out and will circulate back inside.
  • Check the circuit breaker - Make sure the breaker to the outside unit has not tripped. If the breaker has tripped, the unit will keep blowing air into the house without cooling it first. If it keeps tripping a professional will need to be called.

If you have checked these items and your unit is still not cooling the house, call the experts at Garner for repair services. We can diagnose any AC issue and fix it effectively at an affordable rate. Contact us online today for an appointment.

If you'd like to know what your neighbors in Austin, TX think, just check out their reviews below!

Recent Jobs and Reviews in Austin, TX

Rated 4.9 out of 5 stars based on 78 customer reviews

Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting high levels of customer satisfaction and appreciation. Customers consistently express gratitude for the professionalism, punctuality, and expertise demonstrated by the service team. There is a strong recurring theme of technicians being knowledgeable, thorough, and excellent communicators who take time to explain issues, answer questions, and provide helpful advice without applying undue pressure. Many reviewers highlight the courteous and respectful nature of the staff, noting details such as wearing shoe covers, protecting work areas, and leaving spaces clean after completion. Timeliness emerges as another dominant positive trend, with numerous mentions of technicians arriving on time or even early, completing work efficiently, and providing same-day service. Customers frequently express confidence in the quality of work performed, even under challenging conditions like extreme heat, and many indicate strong loyalty, stating they will use the service again and recommend it to family and friends. The emotional tone is enthusiastic and appreciative, with reviewers describing their experiences as "great," "excellent," "fantastic," and "outstanding." Overall, the reviews convey a sense of trust, reliability, and exceptional customer care that has clearly resonated with clients.

Austin, TX at a glance

Garner Heating & Air Conditioning Inc has completed 25 jobs in Austin, TX between March 2025 and June 2025.

The most recent job was on June 6, 2025.

Garner Heating & Air Conditioning Inc has completed 74 jobs in Austin, TX in the last 12 months. The first job there was in July 2018.

Job Locations and Reviews

Elijah D.
Elijah D. Checked in
Performed semiannual maintenance on one straight cool AC system. Inspected all performance, mechanical and safety systems. I found that the external static pressure of the furnace was high, reaching over 1.02inWC. I lowered the blower speed to bring the CFM rating down to match the tonnage of the cooling system and was able to lower static pressure to .85inWC. This also helped with proper heat and humidity removal of the system. Did verify refrigerant levels were still within operating range after making changes to fan speed. Tested and verified everything was operating within manufacturer specifications for operation. No major issues were found. Everything is working at this time.
Austin, TX 78745
Matt F.
Matt F. Checked in
Service diagnostic found that the condensation drain line was clogged. Water had backed up into the safety switch and shut down the system. Options for repair were presented to the homeowner and Brandi chose to have the drain line cleared. I cleared the drain line and flow tested the drain with two gallons of water. I also treated the drain line. Clear water was observed flowing out the the drain line and the system was running at the completion of service.
Austin, TX 78748
Matt F.
Matt F. Checked in
Service diagnostic found that the condensation drain line was clogged. Buildup in the condensation drain was tripping the safety switch and preventing system operation. Options for repair were presented to Mark and he chose to have the drain line cleared. I cleared the drain line and flow tested the drain with water. Clear water was observed flowing out of the drain line. I also treated the drain line. The system was running at the completion of service.
Austin, TX 78749
Jacob B.
Jacob B. Checked in
Recovered all existing refrigerant. Brazed in new liquid line filter drier. Pressure tested with nitrogen and checked for leaks with bubbles. Purged lineset and pulled vacuum. Charged AC with R-410A refrigerant. All is working at this time
Austin, TX 78747
Jacob B.
Jacob B. Checked in
Recovered all existing refrigerant. Brazed in new liquid line filter drier. Pressure tested with nitrogen and checked for leaks with bubbles. Purged lineset and pulled vacuum. Charged AC with R-410A refrigerant. All is working at this time.
Austin, TX 78747
Omar H.
Omar H. Checked in
Performed A/C tune-up on a Carrier heat pump system. Checked the electrical, mechanical and performance systems of the unit. Cleared, cleaned, flushed and treated the drain line and cleaned the exterior of the air handler. Secured the compressor wiring and washed the outdoor coil. I did find the system was slightly low on refrigerant. I spoke with Mr. Brown and he chose to add refrigerant at this time. I added 1 lbs 6oz of refrigerant. I also performed a leak search but was unable to find a leak. No other issues were found. The system is operational at this time.
Austin, TX 78737
Matt F.
Matt F. Checked in
Service diagnostic found that the capacitor on the condenser unit had failed. Options for repair were presented to the homeowners and they chose to have the capacitor replaced. I replaced the capacitor on the condenser unit and function tested the system. The system is now operational and was running at the completion of service.
Austin, TX 78737
Elijah D.
Elijah D. Checked in
On arrival, I found that the thermostat was powering on and off for each call of cool. I went outside and found that the contactor relay was shorted out and also burned up on the high voltage side due to the aluminum wire not being properly secured or having any anti-oxidant compound. I spoke with homeowner and he approved the repair of the relay and also going ahead and proactively repairing the run capacitor as well. I installed a new contactor relay and new capacitor at the outdoor condenser, I also applied anti-oxidant compound on the aluminum wire from the breaker to the condenser and tightened to 40-45in-lb of torque per manufacturer guidelines. Cycled high voltage power to system and verified operation. Everything is working at this time.
Austin, TX 78741
Ethan D.
Ethan D. Checked in
Removed all existing duct work. Built and installed new extended supply plenum with elbow. Built and installed new return plenums. Added second media filter to new return plenum. Installed all new supply buckets and registers, upsizing where needed. Installed all new flex duct and sheet metal wyes. Sealed all connections with mastic and hardcast. Everything is working at completion of service.
Austin, TX 78737
Elijah D.
Elijah D. Checked in
Performed semiannual maintenance on two heat pump cooling systems. Inspected all performance, mechanical and safety systems. Tested and verified everything was operating within manufacturer specifications for operation. No major issues were found. Everything is working at this time.
Austin, TX 78737
Elijah D.
Elijah D. Checked in
Performed semiannual maintenance on one heat pump Infinity cooling system. Inspected all performance, mechanical and safety systems. Changed out one filter provided by the homeowner. Cleaned the outdoor condenser coil to ensure maximum heat transfer of the refrigerant coil. Verified everything was operating within manufacturer specifications for operation. No major issues were found. Everything is working at this time.
Austin, TX 78737
Angel T.
Angel T. Checked in
Completed duct sealing. Sealed all iboxes and duct board to the sheetrock with mastic. Sealed all duct and system connections for plenums with mastic. Installed Stage 4 Breathe Easy package. Tested system and checked static and system pressures. Everything is operational at completion of service.
Austin, TX 78737
Matt F.
Matt F. Checked in
Performed AC cool check and checked the electrical, mechanical, safety, and performance of the system. I cleared the condensation drain line and flow tested the drain with two gallons of water. The condensation pump for the drain line is operational. Clear water was observed flowing out the end of the drain line. The air filter was clean and had been replaced by the homeowner. Wiring was tightened on the furnace control board. No loose connections or rubbing wires are present. Refrigerant is within factory specifications. Condenser fan motor is in good condition. Condenser capacitor is in value. Condenser coil was cleaned. No major issues were found. The system was running at the completion of service.
Austin, TX 78736
Ethan D.
Ethan D. Checked in
Installed Carrier 3 ton 2 stage R-454B condenser and evaporator coil. Installed Carrier vertical gas furnace with new filter base. New gas pipe and flue pipe connections installed for the furnace. Installed Ecobee pro thermostat. Built and installed new extended supply plenum. Ran new low voltage wire to the thermostat and to the condenser in conduit. Installed new disconnect box and pad for the condenser. Connected existing flex duct to new plenum. All duct connections sealed with mastic/hardcast. Rebuilt primary condensation drain with new safety switch on the secondary. Pressure tested system with nitrogen and pulled vacuum. Cleared condensation drain with CO2 and primed trap with water. Tested heating and cooling operation. Everything is working at completion of service.
Austin, TX 78745
Matt F.
Matt F. Checked in
Performed AC cool check on two systems. Checked the electrical, mechanical, safety, and performance of the systems. I cleared the condensation drain lines and flow tested the systems with two gallons of water. I also treated the drain lines. Air filters were replaced with client supplied filters. Condenser coils were cleaned. The upstairs system capacitor for the condenser unit was below value. Options for repair were presented to the homeowner and they chose to have the capacitor replaced. I replaced the capacitor and function tested the system. The systems were running at the completion of service.
Austin, TX 78737
Matt F.
Matt F. Checked in
Performed AC cool check on three systems and checked the electrical, mechanical, safety, and performance of the systems. I cleared the drain lines and flow tested the drains with two gallons of water. I also treated the drain lines. Condenser coils were cleaned. No major issues were found. The systems were running at the completion of service.
Austin, TX 78749
Elijah D.
Elijah D. Checked in
Performed semiannual maintenance on one gas furnace AC system. Inspected all performance, mechanical and safety systems. Tested and verified everything was operating within manufacturer specifications for operation. No major issues were found. Everything is working at this time.
Austin, TX 78745
Ethan D.
Ethan D. Checked in
Installed Carrier 2 1/2 Ton system. Installed new Ecobee thermostat. Installed new return and supply plenums and sealed all connections with mastic air lock. Replaced secondary drain pan. Rebuilt and insulated primary and secondary drain lines. Cleared drain and verified operation. Installed SS2 and SS3 safety float switches. Installed new disconnect and whip at outdoor condensing system. Re insulated suction line. Verified charge was at manufacturers specifications. Everything is working at completion of service.
Austin, TX 78748
Elijah D.
Elijah D. Checked in
Performed semiannual maintenance on one heat pump cooling system and inspected all performance, mechanical and safety systems. I found the outdoor condenser fan motor leaking oil and overheated. The run capacitor is reading below manufacturer requirements and the contactor relay is burned and pitted across the high voltage contacts. Inside, the blower wheel and the electrical wiring and controls are severely dirty. I checked the underside of the evaporator coil and it is currently clean. Homeowner added support to the drain line outside since our last visit. This is now helping ensure the drain line does not get buried into the dirt, blocking the condensate drainage of the system. Everything is working at this time.
Austin, TX 78737
Elijah D.
Elijah D. Checked in
Performed semiannual maintenance on one AC system and inspected all performance, mechanical and safety systems. Verified everything was operating within manufacturer specifications. No major issues found. The system was running at time of departure.
Austin, TX 78745
Elijah D.
Elijah D. Checked in
Performed semiannual maintenance on one straight cool AC system and inspected all performance, mechanical and safety systems. Tested and verified everything was operating within manufacturer specifications. No major issues were found. Everything is working at this time.
Austin, TX 78748
Elijah D.
Elijah D. Checked in
Performed semiannual maintenance on one straight cool AC system and inspected all performance, mechanical and safety systems. Cleaned and cleared the primary drain line, washed out the outdoor condensing coils and verified everything was operating within manufacturer specifications for operation. No major issues were found. Everything is working at this time.
Austin, TX 78748
Elijah D.
Elijah D. Checked in
Performed semiannual maintenance on one straight cool AC system and inspected all performance, mechanical and safety systems. I found the outdoor condenser fan motor to be leaking oil, and the fan motor bearings are not turning smoothly anymore. A soft start kit was previously installed. I tested the LRA amps and found them to be well below the rated value. Everything is working at this time.
Austin, TX 78737
Elijah D.
Elijah D. Checked in
Performed semiannual maintenance on two AC systems and inspected all performance, mechanical and safety systems. Tested and verified everything was operating within manufacturer specifications for operation. All Stage 3 & Stage 4 Breathe Easy systems are on and operational. Reset the filter and maintenance reminders on Ecobee thermostats prior to leaving. Ensured all disconnects were reset and systems cycled on. No major issues found. Everything is working at this time.
Austin, TX 78735
Ethan D.
Ethan D. Checked in
Installed new extended supply plenum. Installed all new flex, buckets and supply registers; upsizing where needed. Sealed all connections with mastic / hard cast. Cleaned out both ceiling returns. Installed 2 new return grilles. Moved high voltage wires to furnace inside the closet as they were previously plugged outside the closet. Cleared primary condensation drain and tested with water.
Austin, TX 78748
Kyle . Buda . San Marcos . Wimberley . Driftwood . Martindale . Manchaca . Lockhart . New Braunfels
Schedule Now Text Us Now
Award Winning Service
  • Google Guaranteed
  • Carrier Authorized Dealer Logo
  • Service Round Table Member Logo
  • Best Or North Hays Logo
  • Nate Certified Technicians Logo
  • National Comfort Institute Inc Logo