Expert HVAC Service in Austin TX
Since 1988, residents of Austin, TX have trusted Garner Heating & Air Conditioning to provide professional work and outstanding service for all of their HVAC needs. If you're looking for a provider you can count on, call today!
It costs around $200-$400 to replace an AC line in Austin, TX. The cost of the replacement can vary depending on:
- The cost of the AC line.
- If other parts also need to be replaced.
- The contractor’s hourly rate.
AC lines can be fairly inexpensive to replace, but the overall cost can increase if you need to have other components replaced along with the AC line. To get your AC line replaced, contact us today.
A few reasons you may want to replace your home air conditioner rather than repair it in Austin, TX include:
- Your air conditioner is over 10 years old.
- Your air conditioner breaks down often.
- Your air conditioner does not cool you home effectively.
Another reason you may want to replace your home air conditioner rather than repair it is if the cost to repair it is more than half of the cost to replace it. A newer and more efficient unit will be able to run smoother and cost you less on energy each month. To get your home air conditioner replaced, call us today.
If your home air conditioner has a higher SEER rating, it can cool your home more efficiently than other systems. Since the higher SEER rating can make your air conditioner more efficient, it will also typically cost you less on energy costs each month. Although, you should ensure that your air conditioner’s SEER rating matches your specific needs to ensure that it is able to work its most efficiently in your area's climate. To learn more about what SEER rating your air conditioner should have, give us a call today.
To repair an AC unit in the Austin, TX area, you can expect to pay between $350 - $800 on average. This cost varies depending on what needs to be fixed. Most repairs are minor fixes, and average around $350. Major repairs, such as complicated refrigerant leaks or compressor replacements, can top $2,500.
Average Cost: $350
Typical Range: $350 - $800
At Garner Heating & Air, we provide reliable honest AC repair services at affordable prices. Contact us online today for more information or to get on our schedule.
A trained technician should be called to fix a refrigerant leak. You can’t just add refrigerant to a system like you would oil to a car for a few reasons:
- Refrigerant is a dangerous thing to work with and can be hazardous if you do not have the proper experience and equipment.
- Leaks need to be repaired correctly as refrigerant can be harmful to the environment if spilled.
- The amount of refrigerant in the system needs to match the manufacturer’s recommendation exactly or the unit will not perform to its best ability.
A technician will be able to accurately diagnose where the leak is, whether they can solder the pipe or have to replace the coils and the precise amount of refrigerant to add to correctly charge the system.
There could be a few reasons your air conditioner is running but not cooling the house. Before you call an AC repair company, there are some measures you can take that may solve the problem:
- Turn the thermostat to AUTO if it was set to ON - When turned to the ON setting, the blower will run continuously even when the unit is not producing cool air. Setting the system to AUTO allows the unit to cycle the way it was built to and recharge.
- Change the air filter - If the filter is dirty, it might be clogging the system so air cannot circulate properly. When airflow is blocked, this could cause the system to struggle to cool the home.
- Clean the outdoor unit - When the condenser is dirty, the warm air the unit is trying to expel cannot get out and will circulate back inside.
- Check the circuit breaker - Make sure the breaker to the outside unit has not tripped. If the breaker has tripped, the unit will keep blowing air into the house without cooling it first. If it keeps tripping a professional will need to be called.
If you have checked these items and your unit is still not cooling the house, call the experts at Garner for repair services. We can diagnose any AC issue and fix it effectively at an affordable rate. Contact us online today for an appointment.
If you'd like to know what your neighbors in Austin, TX think, just check out their reviews below!
Recent Jobs and Reviews in Austin, TX
Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting high levels of customer satisfaction and appreciation. Customers consistently express gratitude for the professionalism, punctuality, and expertise demonstrated by the service team. There is a strong recurring theme of technicians being knowledgeable, thorough, and excellent communicators who take time to explain issues, answer questions, and provide helpful advice without applying undue pressure. Many reviewers highlight the courteous and respectful nature of the staff, noting details such as wearing shoe covers, protecting work areas, and leaving spaces clean after completion. Timeliness emerges as another dominant positive trend, with numerous mentions of technicians arriving on time or even early, completing work efficiently, and providing same-day service. Customers frequently express confidence in the quality of work performed, even under challenging conditions like extreme heat, and many indicate strong loyalty, stating they will use the service again and recommend it to family and friends. The emotional tone is enthusiastic and appreciative, with reviewers describing their experiences as "great," "excellent," "fantastic," and "outstanding." Overall, the reviews convey a sense of trust, reliability, and exceptional customer care that has clearly resonated with clients.
Austin, TX at a glance
Garner Heating & Air Conditioning Inc has completed 25 jobs in Austin, TX between May 2024 and August 2024.
The most recent job was on August 2, 2024.
Garner Heating & Air Conditioning Inc has completed 74 jobs in Austin, TX in the last 12 months. The first job there was in July 2018.
Our Local Reviews by City
- Austin, TX (78)
- Buda, TX (331)
- Canyon Lake, TX (5)
- Creedmoor, TX (4)
- Dale, TX (1)
- Driftwood, TX (29)
- Dripping Springs, TX (26)
- Hays, TX (1)
- Kingsbury, TX (1)
- Kyle, TX (484)
- Lockhart, TX (15)
- Manchaca, TX (9)
- Martindale, TX (14)
- Maxwell, TX (3)
- Mountain City, TX (26)
- New Braunfels, TX (13)
- Niederwald, TX (15)
- San Marcos, TX (157)
- Seguin, TX (3)
- Uhland, TX (2)
- West Lake Hills, TX (1)
- Wimberley, TX (104)
- Woodcreek, TX (4)
Job Locations and Reviews
Replaced all upstairs flex ducts and I-boxes. Installed new supply registers and sealed buckets with air lock and spray foam. Replaced both return and supply plenums. Ran and hung insulated hard pipe to connection points. Re-insulated the primary drain line and added a second vent. Also installed a drip leg on the gas line. Installed dampers and sealed connection pieces with air lock. Everything is working at this time.
On arrival, I spoke with the homeowner, and he stated that he noticed his drain line was slightly dirty. I went into the hall closet and found that the water safety switch was tripped. I removed the plunger, and the outdoor unit immediately came on. I turned off the system and removed the water from the float switch. While doing this, I also noticed the drain line was still slightly clogged so I cleared and treated it again. Reset power to system and checked over the outdoor unit. Verified system was operating with a 10°SC and all electrical items were operating within manufacture’s specifications for operation. Everything is working at this time.
Performed semiannual maintenance on one straight cool cooling system. Inspected all Performance, Mechanical and Safety Systems. Tested and verified all mechanical components were operating within manufacture’s specifications for operation. Also removed all vines that had begun to grow into the outdoor unit. Verified all electrical components in the outdoor unit were operating within manufacture range for operation. Everything is working at this time.
Performed semiannual maintenance on one heat pump cooling system. Inspected all Performance, Mechanical and Safety Systems. Homeowner changed the filter prior to our arrival. I cleared the drain line and verified that all Stage 3 Breathe Easy systems are on and operating as designed. I found that the outdoor run capacitor has fallen below manufacture range for operation. The HERM side is reading 37 out of 40mfd and the FAN side is reading 2.9 out of 5mfd. I presented my findings to the homeowner, and they decided to have the capacitor replaced today. I installed a new run capacitor and tested the system. Everything is working at this time.
Performed semiannual maintenance on two Carrier Inverter systems. Inspected all Performance, Mechanical and Safety systems. Tested and verified all mechanical components were operating within manufacture’s specifications for operation. Washed the outdoor condensing coils to help ensure proper heat transfer of the refrigerant. Also, per customer's request, I adjusted the balancing damper for the upstairs living room area to allow for more airflow as they had removed some furniture from the area. Verified everything was operating within manufacture’s specifications for operation. Everything is working at this time.
On arrival, homeowner stated that the air coming out of the vents was no longer cool and the house got up to 80°+. I set the thermostat to COOL mode and noticed the lights flickered when I did. I went outside and found that the condenser fan motor was running, and the compressor was not. I removed the run capacitor from the unit and found the capacitor to be reading 2.6mfd out of 45mfd across the HERM terminals. I tested the FAN side and found that to be a reading of 4.8mfd out of 5mfd. Installed a new run capacitor in the system and secured all wiring terminals. Restored high voltage power to system and checked over operations. Verified the electrical amp draw of the compressor and fan motor were within range, along with the refrigerant which was running a 8°SH and a 8°SC. I also found that the refrigerant service valves did not have any caps installed, so I went ahead and placed two new locking R-410A caps onto the unit and ensured the Schrader cores were tightened to spe
Performed semiannual maintenance on one straight cool cooling system. Inspected all Performance, Mechanical and Safety Systems. Tested and verified all mechanical components were operating within manufacture’s specifications for operation.
Performed semiannual maintenance on one cooling system. Inspected all Performance, Mechanical and Safety systems. Cleaned the outdoor condensing coils to help improve heat transfer of the refrigerant. Flushed and treated the primary drain line and verified proper flow of condensate. Tested and verified all mechanical components were operating within manufacture’s specifications for operation. Everything is working at this time.
Performed semiannual maintenance on one gas system. Inspected all Performance, Mechanical and Safety Systems. Tested and verified all mechanical components were operating within manufacture’s specifications for operation. Everything is working at this time.
Performed semiannual maintenance on one straight electric cooling system. Inspected all Performance, Mechanical and Safety Systems. I washed the outdoor condensing unit and cleared the drain line. Tested and verified all mechanical components were operating within manufacture’s specifications for operation. Everything is working at this time.
Performed semiannual maintenance on one straight electric cool unit. Inspected all Performance, Mechanical and Safety Systems. Tested and verified all mechanical components were operating within manufacture’s specifications for operation. I also adjusted the slope of the primary drain line, as it was leaning back towards the indoor coil, which was not allowing for proper condensate drainage to the outside drain exit. No other major issues found.
Service diagnostic found that the drain line is clogged causing water to back up into the safety switch and shut down the condenser unit. Options for repair were presented to the customer, and he chose to have the drain line cleared. I cleared the drain line and flow tested it with water. I then treated the drain line and function checked the system. The system is running at the time of departure.
Performed semiannual maintenance on one straight electric cooling unit. Inspected all Performance, Mechanical and Safety Systems. Verified all mechanical components were operating within manufacture’s specifications for operation. Mr. Funderburgh changed out the AprilAire 510 filter about a month ago, so the filter was still in good condition. Verified everything was operating within manufacture’s specifications for operation. Everything is working at this time.
Performed semiannual maintenance on one straight electric cooling unit. Inspected all Performance, Mechanical and Safety systems. Flushed and treated the primary drain line. Tested and verified all mechanical components were operating within manufacture’s specifications for operation. Everything is working at this time.
Performed semiannual maintenance on one straight electric cooling system. Inspected all Performance, Mechanical and Safety Systems. Changed out all ceiling return air filters provided by the Bader’s. During the maintenance I found that the outdoor run capacitor has fallen below value: currently reading 52mfd out of 70mfd. I confirmed that all zone dampers are currently operational and that the whole home dehumidifier is running as well. Rinsed off the outdoor condensing coils, as there was some dust build up between the fins. Reset thermostats back to setpoint and verified all other mechanical components were operating within manufacture’s specifications for operation. Everything is working at this time.
Removed the blower assembly and disassembled it. Installed new blower motor and new blower wheel. Reassembled the blower assembly and installed it back into the system. Turned the system on and checked operation. Cleared, flushed and treated the condensate drain line. Allowed the system to run and start cooling the house down before leaving. The system is operating properly at this time.
Installed new 3-ton Carrier gas system. Installed new Ecobee Lite thermostat. Rebuilt and insulated the condensate drain line. Added SS2 and SS3 safety float switches. Cleared drain line with CO2 and ran three gallons of water to ensure proper operation. We then followed that with Viper drain treatment. Installed new filter dryer, pressure tested with dry nitrogen, and pulled a vacuum on copper line set. Replaced the disconnect and ran the low voltage in Seal-Tite. Replaced both the supply and return plenums and sealed with mastic airlock. Charged system to factory spec and performed a benchmark. The system is working properly at time of departure.
Performed semiannual maintenance on one straight electric cooling system. Inspected all Performance, Mechanical and Safety Systems. I did find that the outdoor run capacitor has failed across both the HERM and FAN terminals. The FAN terminal is reading 1.2mfd out of 5mfd and the HERM terminal is reading 39mfd out of 45mfd. The fan motor is also overamping above the rated limit due to the failed run capacitor. Spoke with the homeowner and she chose to have it replaced today to avoid future cooling issues. I installed a new run capacitor and tested the unit again. The fan motor electrical amp draw is now back within range and system is cooling again. No other major issues found, and everything is working at this time.
Performed semiannual maintenance on one heat pump cooling system. Inspected all Performance, Mechanical and Safety Systems. Flushed and treated the primary drain line. I did find that the drain line piping that runs outside near the condenser had gotten buried under the dirt. I was able to lift it out to help ensure condensate drains properly. Applied a drain treatment inside the primary drain line and in the internal drain pan. Homeowners did mention that the Ecobee would constantly show high humidity alerts (above 70%) and were concerned if the dehumidification function of the unit was operating properly. I went through the system and verified airflow and refrigerants levels were set properly. I did notice when going through the Ecobee wiring setup that the thermostat was registering that there was a wire plugged into ACC, instead of ACC+. I was able to manually configure the wiring program of the thermostat to correct the wiring to ACC+ which is connected to the DEHUM input on
Arrive to find no power to the upstairs thermostat. Performed diagnostic. Checked the fuse in the furnace and found that it had popped. I then went outside to test the contactor and found the contactor’s resistance at 2.0 indicating a failed contactor. Replace contactor and fuse. Cycled cool mode and the system is now cooling properly.
On arrival, I found the Nest thermostat with an error code of “no 24v to R”. I went into the furnace closet and found that the emergency water safety switch was tripped due to a restricted drain line. I flushed and treated the primary drain line and cleaned out the float switch. I reset the AC unit and tested the system. I did inform the homeowner that the furnace was still original from 2005, and I did see some rust forming along the inducer motor and heat exchanger assembly. I recommended that he make sure the furnace gets checked out prior to heating season to ensure it is safe to run. Verified everything was operating within manufacture’s specifications for operation. Everything is working at this time.
Downstairs HVAC System: On arrival, I found that the downstairs system compressor was not pumping any refrigerant throughout the system, but the condenser fan motor was spinning. I removed the outdoor electrical panel for the system and found that the run capacitor was just thrown into the packaging box and left in the system; not properly mounted or secured. I tested the run capacitor and found it has failed across the HERM terminal. I did also test the FAN terminal and found that it was starting to fail as well, measuring well below the 10% value of the rating. I also noted that the condenser fan motor has been replaced before. The data tag of the unit calls for a 1/15HP motor and it was changed out with a 1/4HP motor. Due to this, the new motor is too long in length which is making the fan blade sit below the fan shroud, so as the fan motor is running, it is not moving air correctly out of the coil and out of the system. I installed the correct size run capacitor and proper
Installed new TXV on the evaporator coil. Replaced the inline filter dryer, pressure tested with dry nitrogen and pulled a vacuum on the copper line set. Cleared and treated the condensation drain line. Charged system to factory specs and check operation. The system is working at this time.
System was off when I arrived. The homeowner stated that it was only blowing hot air the last two days, but they noticed the condenser fan running. Performed the diagnostic and found that the dual capacitor has failed. Presented repair options and the homeowner decided to have the capacitor replaced today. Completed repair and cycled thermostat. System operational upon completion of repairs.
Performed semiannual maintenance on two comfort cooling systems. Inspected all Performance, Mechanical and Safety Systems. Spoke with homeowner and she stated that the upstairs unit’s condenser would make a loud metal noise on startup/shutdown. I went through the unit and cycled the system multiple times from the disconnect. I ensured all screw mounts were secured properly. System sounded and operated as designed. Verified everything was operating within manufacture’s specifications for operation. Everything is working at this time.