Life never stops moving, and these days things are busier than ever. The last thing anyone wants is to come home on a blisteringly hot day to find the temperature inside their home matches the searing heat outside. Whether it's servicing your system to make sure it's ready to go as temperatures climb or fixing it properly when something's gone wrong, Garner Heating & Air Conditioning is there when you need us. Plus, we can take a look at your existing system and offer solutions to your ductwork and filtering to ensure you're getting the best indoor air quality. At Garner, we take care of your system top to bottom and inside-out.
Your air conditioner capacitor is the device that provides your unit with the initial power boost it needs to cycle on. It also supplies power to the AC that allows the unit to complete a cooling cycle. Some signs that your capacitor may not be working include:
- The air conditioner will either not turn on or take a while to start after you turn it on.
- The unit is not blowing cold air.
- There is a humming noise coming from the AC.
- The unit keeps shutting down.
Do you suspect a bad AC capacitor? Garner Heating & Air Conditioning can help! We provide accurate and reliable AC repair services at competitive prices. Contact us today to learn more!
On average, you can expect your AC unit to last between 10 - 15 years. To prolong the life of your unit, make sure to:
- Have it serviced regularly - Maintenance service has been shown to not only help central air conditioning systems last longer, but also run more efficiently and ward off future breakdowns.
- Run it reasonably - Our Texas summers can be brutal. However, if the temperature hits over a hundred degrees outside, trying to cool your home to 60 degrees will put undue stress on the unit and shorten its working life.
- Change filters on time - Changing the air filters in your home helps your AC run more smoothly by allowing air to circulate easier. New air filters also collect more dust and dirt that will prevent extra debris from getting into the system.
To learn more, contact the experts at Garner Heating & Air Conditioning today! We offer professional AC installation services guaranteed to keep you and your family cool for years to come.
On average, the repair cost to replace an AC capacitor runs around $300 - $400 for a professional technician to complete. You can expect the job to take between 1 - 2 hours.
For a more accurate estimate, Garner Heating & Air Conditioning can help! We offer “Peace Of Mind” pricing, which means we provide the price before doing the repair and never add an additional charge on top of it. Contact us today to learn more!
Having a new air conditioning system installed in Driftwood can cost anywhere from $7,000-$15,000, with most people paying an average of $10,000. Some of the factors that can influence the cost of installation include the labor costs, the size of your home and the size, brand and type of air conditioner you want installed.
Garner Heating & Air Conditioning offers the best AC services in Driftwood. To have a new AC system installed in your home, give us a call today!
Along with improving your system’s efficiency and helping your units to last longer, regular HVAC maintenance can find any problems your heating and cooling systems may be having and can help to prevent future problems from occurring. HVAC systems need to be serviced once a year. Typically, it’s ideal to have your AC serviced in the Spring and your heater serviced in the Fall. This way, you can rest assured that your HVAC systems will last you through the months you’ll use them the most.
To get on our HVAC maintenance plan, give Garner Heating & Air Conditioning a call today!
HVAC systems typically last around 15-20 years before they’ll need to be replaced, but you can help to extend their useful life by having them properly maintained. However, they may need to be replaced sooner if they break down frequently or lose efficiency. Some common signs you may need to have your HVAC systems replaced soon include:
- Higher energy bills.
- The cost to have your HVAC unit repaired is more than half the cost of a new unit.
- Uneven temperatures in your home.
- Loud noises coming from the unit.
- Unpleasant odors coming from your HVAC system.
Give Garner Heating & Air Conditioning a call for dependable HVAC replacement services today!
Reliable Service, Real Results
Garner Heating & Air Conditioning offers a wide range of services that can make sure your home remains the comfortable oasis you want it to be:
Air Conditioning: AC Maintenance / AC Repair / AC Replacement / Ductless Mini-Splits Heating: Heat Pumps Ductwork: Repair & Sealing / Installation Duct Cleaning Services Indoor Air Quality: Air & Furnace Filters / UV Lights / Media Air Cleaners Attic Insulation
Expert AC Repair for Central Texas
Garner Heating & Air Conditioning is family-run and family-focused, and we'd like your family to be a part of ours. Whether you need a one-time fix or are interested in one of our comprehensive maintenance plans, we're certain once you experience the Garner difference you'll be a fan for life. Give us a call today at 512-392-2000 and let us be your partner in comfort - your home will thank you.
Still not convinced? Listen to what your neighbors in Driftwood, TX have to say about us! Check out their reviews below:
Recent Jobs and Reviews in Driftwood, TX
Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting high levels of customer satisfaction and appreciation. Customers consistently express gratitude for the professionalism, punctuality, and expertise demonstrated by the service team. There is a strong recurring theme of technicians being knowledgeable, thorough, and excellent communicators who take time to explain issues, answer questions, and provide helpful advice without applying undue pressure. Many reviewers highlight the courteous and respectful nature of the staff, noting details such as wearing shoe covers, protecting work areas, and leaving spaces clean after completion. Timeliness emerges as another dominant positive trend, with numerous mentions of technicians arriving on time or even early, completing work efficiently, and providing same-day service. Customers frequently express confidence in the quality of work performed, even under challenging conditions like extreme heat, and many indicate strong loyalty, stating they will use the service again and recommend it to family and friends. The emotional tone is enthusiastic and appreciative, with reviewers describing their experiences as "great," "excellent," "fantastic," and "outstanding." Overall, the reviews convey a sense of trust, reliability, and exceptional customer care that has clearly resonated with clients.
Driftwood, TX at a glance
Garner Heating & Air Conditioning Inc has completed 20 jobs in Driftwood, TX between January 2024 and May 2024.
The most recent job was on May 13, 2024.
Garner Heating & Air Conditioning Inc has completed 30 jobs in Driftwood, TX in the last 12 months. The first job there was in July 2018.
Our Local Reviews by City
- Austin, TX (78)
- Buda, TX (331)
- Canyon Lake, TX (5)
- Creedmoor, TX (4)
- Dale, TX (1)
- Driftwood, TX (29)
- Dripping Springs, TX (26)
- Hays, TX (1)
- Kingsbury, TX (1)
- Kyle, TX (482)
- Lockhart, TX (15)
- Manchaca, TX (9)
- Martindale, TX (14)
- Maxwell, TX (3)
- Mountain City, TX (26)
- New Braunfels, TX (13)
- Niederwald, TX (15)
- San Marcos, TX (157)
- Seguin, TX (3)
- Uhland, TX (2)
- West Lake Hills, TX (1)
- Wimberley, TX (104)
- Woodcreek, TX (4)
Job Locations and Reviews
I made sure to clear and treat the drain as well as rinse out the heat pump outside. I checked over the entire system and found everything to be in great working order for its age. I didn’t have any major concerns with the system.
I made sure to clear and treat the drain as well as rinse out the heat pump outside. I checked over the entire system and found everything to be in great working order for its age. I didn’t have any major concerns with the system.
Performed AC cool check. Checked electrical, mechanical, safety, and performance of the system. The drain line was cleared and treated. The blower wheel is clean, and the blower motor capacitor is within value. The UV light on the evaporator coil is operational. Condenser coil clean. Condenser fan motor and contactor are in good condition. The condenser capacitor is within value and the refrigerant charge is at factory specifications. No major issues were found.
Replaced both condenser fan motors and installed surge protection on the downstairs condenser. Both systems were function checked and were running at the time of departure.
On arrival, I met with Mr. Adam, and he showed me the inspection report which reported a yellow flame at the burners. I turned the thermostat to heating mode and found the flame coming back into the burners and some soot build up over the heat exchanger burners. I did notice when installation of the LP kit was originally done, the mixing screws were never installed. I went through the LP conversion kit box and found that two of the four mixing screws were missing. Installed new LP kit at furnace, adjusted fuel pressure to 11inWC and did a CO test at furnace and inside home. Verified everything was operating within manufacture’s specifications for operation. Everything is working at this time.
On the return visit we sealed both systems from return to supply. Every joint and duct connection was sealed with mastic. Each seam was sealed on both systems. The coils of both systems were sprayed down with the Viper evaporator coil cleaner.
Performed AC cool check. Checked electrical, mechanical, safety, and performance of the system. The air handler and blower wheel are clean. The evaporator coil is also clean. The wiring is tight and in good condition. Drain line was cleared and treated. The condenser fan motor is in good condition. Condenser capacitor is within value. Electrical disconnect and contactor are also in good condition. The condenser coil is clean. No major issues were found, and the system was running at the time of departure.
Main Common Area HVAC System: On arrival I found the indoor blower motor would not turn on. Tested the run capacitor and found it to have failed below value. Went to spin the blower wheel and found that it had slid off the blower motor shaft and was rubbing against the indoor blower housing. Removed the blower motor and noticed that a substantial amount of grease had leaked out of the motor which caused the wheel hub to slide off the shaft. Recommend replacement of the indoor blower motor to return system back to operation. Installed new indoor PSC Blower Motor, installed new run capacitor and tested system in both heating and cooling modes. Verified everything was operating within manufacture’s specifications for operation. Everything is working at this time.
Removed old duct board and heat pump system. Replaced with a new 4-ton heat pump system. Installed extended plenum. Removed the old drain and installed a new drain. Removed the old drain pan and replaced it with a new drain pan. Replaced condenser pad with new pad. Brazed in new condenser. Brazed in new heat pump filter dryer inside near coil. Reattached ducts. Pressure tested and vacuum tested. Drain cleared. Everything is working properly.
Service diagnostic found that the condensate drain line was clogged. Water had backed up into the secondary drain and tripped the safety switch. The drain line was piped in a way that prevented treating or clearing the drain effectively. I installed a vent on the primary drain that allows the trap and the drain to be cleared. I then cleared the drain and flow tested the drain line with water. I also treated the drain line. System was running at the time of departure.
Performed AC cool check. Checked electrical, mechanical, safety, and performance of the system. The door switch for the furnace was bypassed. I wired the door switch back in so that it turns off the power while open. The capacitor for the blower motor had been replaced but was unsecured and left hanging by the wires so I secured the capacitor in place. There was a start kit installed on the condenser and it was also unsecured, so I secured it as well. The secondary drain line is piped into the secondary pan and could flow water without tripping the switch in the pan. No other major issues were found. See attached checklist for full tune-up details. Options for repair were presented to the customer and she chose to have a safety switch installed on the secondary drain line. Repair was completed and the system was function checked. System was running at the time of departure.
Performed semiannual maintenance on one heat pump heating system. Inspected all Performance, Mechanical and Safety Systems. I found that the April Aire 4” Media Filter was extremely clogged up creating an inflow restriction across the indoor coil. They had a new filter on-site, so I changed it out. Tested the refrigerant system and verified the system was operating with a 10° subcooling value and had the proper heat transfer across both indoor and outdoor coils. Verified everything was operating within manufacture’s specifications for operation. Everything is working at this time. See attached checklist for full tune-up details.
I made sure to clean the flame sensors on both furnaces. I also replaced both filters with customer supplied filters. I checked over both systems and found them to be in great shape. I didn’t notice anything out of the ordinary or worn. The systems were heating well and operating within factory specifications at all testable parameters. Systems are in working order at completion of appointment. See attached checklists for full tune-up details.
I made sure to clean the flame sensors on both furnaces. I also replaced both filters with customer supplied filters. I checked over both systems and found them to be in great shape. I didn’t notice anything out of the ordinary or worn. The systems were heating well and operating within factory specifications at all testable parameters. Systems are in working order at completion of appointment. See attached checklists for full tune-up details.
I made sure to clean the flame sensors on both furnaces. I also replaced both filters with customer supplied filters. I checked over both systems and found them to be in great shape. I didn’t notice anything out of the ordinary or worn. The systems were heating well and operating within factory specifications at all testable parameters. Systems are in working order at completion of appointment. See attached checklists for full tune-up details.
I made sure to clean the flame sensors on both furnaces. I also replaced both filters with customer supplied filters. I checked over both systems and found them to be in great shape. I didn’t notice anything out of the ordinary or worn. The systems were heating well and operating within factory specifications at all testable parameters. Systems are in working order at completion of appointment. See attached checklists for full tune-up details.
Performed heater check on three Carrier gas furnaces. These systems have all been converted to propane. Checked electrical, mechanical, safety, and performance of the systems. Drain lines were cleared and treated. All return and supply plenums are clean. Blower wheels are also clean. Igniters are operational and in value. Inducer motors are running at normal amperage. All systems are in good condition. Systems are running at the time of departure. See attached checklists for full tune-up details.
Performed heating maintenance on two furnace systems. Checked all electrical, mechanical and performance of the system. Cleared and treated the drain line and replaced both media air filters. No major issues were found, and both systems are operational at this time. See attached checklists for full tune-up details.
Performed heating maintenance on one heat pump system. Checked all electrical, mechanical and performance of the system. Customer supplied filter for replacement. I found that the system has a dirty blower wheel and also found small amounts of microbial growth in the air handler and on the evaporator coil. I presented the customer with options for repair but he declined repairs at this time. No other major issues were found, and the system is operational at this time. See attached checklist for full tune-up details.
Installed new 2.5-ton Carrier heat pump system. Installed new Ecobee Pro thermostat. Installed new extended supply plenum and sealed with mastic air lock. Installed new return plenum. Replaced secondary drain pan and hung the drain pan. Installed new liquid line filter dryer. Pressure tested line set with nitrogen and pulled a vacuum on the line set. Rebuilt and insulated condensate drain line. Added SS2 and SS3 safety float switches. Replaced outdoor disconnect and ran low voltage in 1/2-inch Seal-Tite. Cleared drain and verified system operation.