Expert HVAC Service in Dripping Springs TX
Since 1988, residents of Dripping Springs, TX have trusted Garner Heating & Air Conditioning to provide professional work and outstanding service for all of their HVAC needs. If you're looking for a provider you can count on, call today!
Some of the symptoms of bad indoor air quality in your Dripping Springs home are:
- Dry throat, nose and eyes.
- Dry or irritated skin.
- Increased allergies indoors.
Bad indoor air quality can also cause your home issues, such as mold growth, due to excessive humidity levels. To find out more about improving the indoor air quality of your home, contact us today.
It costs around $350-$3500 to repair a home air conditioner in Dripping Springs. Some things that can cause the price of the repair to vary include:
- How extensive the repair is.
- What type of repair is required.
- Whether replacement parts are needed.
Some repairs can be fairly inexpensive, whereas refrigerant leaks can be expensive due to the cost to replace the refrigerant in your AC system. To get your home air conditioner repaired, call us today.
Yes, AC tune ups are worth it in Dripping Springs. Some of the benefits of having your AC unit tuned up are:
- Your AC unit runs more smoothly.
- Your AC unit uses less energy.
- Your AC unit breaks down less.
Another benefit to having your air conditioner tuned up is that it will require less repairs and cool your home better. To get the best results, you should have your AC unit tuned up at least once a year. To get your AC unit tuned up, give us a call today!
There could be a number of issues with your air conditioner that is causing it to blow hot air in your home near Dripping Springs TX. Try troubleshooting a few common reasons first before calling a technician:
- Turn the thermostat to AUTO if it was set to ON so that the unit can complete a full cooling cycle.
- Change the air filter in order for the air to be able to circulate properly throughout your home.
- Clean the outdoor unit so that the unit can expel warm air from your home.
- Check the circuit breaker in case it has tripped which will cause it to still operate but not produce cool air.
If you have checked these items and your unit is still not cooling the house, your next step should be a call to a professional. The expert technicians at Garner can diagnose any AC repair issue and fix it effectively at an affordable rate. Contact us online today for an appointment.
On average, in the Dripping Springs TX area you can expect to pay anywhere from $250 - $1,500 to a freon leak repair. It can be hard to estimate the cost of a freon leak in an air conditioner as the price depends almost entirely on where the leak is located and the size of it. A hard to find severe leak could take technicians all day to repair, which will increase costs of labor.
For a more accurate estimate on repair services, the knowledgeable team members at Garner are happy to help. Contact us today to learn more about freon leaks and their costs!
An AC compressor works to move refrigerant throughout the unit to ultimately produce the cool air for your home. When it goes bad, there are a few signs you should be on the lookout for:
- Weird noises.
- Unit will not start.
- Air is not cooling.
- Breaker keeps tripping.
- Less air coming from vents.
Do you suspect your compressor is going bad? Contact Garner today for precise reliable AC repair services!
If you'd like to know what your neighbors in Dripping Springs, TX think, just check out their reviews below!
Recent Jobs and Reviews in Dripping Springs, TX
Customers say: The reviews exhibit a positive sentiment overall, with many customers expressing satisfaction with the services provided. The technicians are often described as friendly, knowledgeable, and professional, with some customers highlighting their punctuality and thoroughness. There are also mentions of excellent customer service, with technicians taking the time to explain the work done and answer any questions. Additionally, customers appreciate the cleanliness and quietness maintained during the service, as well as the respect shown for their property. The recurring themes include professionalism, expertise, courtesy, and efficiency. Overall, the reviews suggest that customers have had positive experiences with Garner Heating and Air Conditioning and would recommend their services.
Our Local Reviews by City
- Austin, TX (61)
- Buda, TX (238)
- Canyon Lake, TX (1)
- Creedmoor, TX (2)
- Dale, TX (1)
- Driftwood, TX (21)
- Dripping Springs, TX (17)
- Hays, TX (1)
- Kingsbury, TX (1)
- Kyle, TX (338)
- Lockhart, TX (12)
- Manchaca, TX (6)
- Martindale, TX (10)
- Maxwell, TX (3)
- Mountain City, TX (20)
- New Braunfels, TX (10)
- Niederwald, TX (5)
- San Marcos, TX (112)
- Seguin, TX (1)
- Uhland, TX (1)
- West Lake Hills, TX (1)
- Wimberley, TX (64)
- Woodcreek, TX (2)
Job Locations and Reviews
Performed semiannual maintenance on two dual fuel heat pump/gas furnace systems. Inspected all Performance, Mechanical and Safety systems. Tested and verified everything was operating within manufacture specifications for operation. Changed out two 2” air filters provided by homeowner in the upstairs attic filter bases. Also flushed and treated the primary drain lines on both AC systems. Everything is working at this time.
Furnace Ignition Repair – A homeowner reported that their furnace was igniting but would quickly shut off. My assessment revealed that the flame rollout switch had tripped due to a buildup of debris in the burner compartment. I cleaned the compartment and reset the switch, ensuring the furnace stayed on and operated safely.
Installed new American Standard air handler in the attic. Reinstalled supply and return plenums with additional support bracing underneath. Rebuilt drain line with SS-2 and SS-3 safety float switches. Cleared drain line, and tested system operation. Everything is working at this time
Performed heater tune-up. I found a partial clog in the primary drain line. I cleared the line with compressed air and then flushed it with two gallons of water followed by drain treatment. No other major issues found.
Performed heater tune-up. I found a partial clog in the primary drain line. I cleared the line with compressed air and then flushed it with two gallons of water followed by drain treatment. No other major issues found.
Performed heater tune-up. I found a partial clog in the primary drain line. I cleared the line with compressed air and then flushed it with two gallons of water followed by drain treatment. No other major issues found.
Performed heater tune-up. I found a partial clog in the primary drain line. I cleared the line with compressed air and then flushed it with two gallons of water followed by drain treatment. No other major issues found.
Removed the three 6” flex runs to the 2 bedrooms and office. Increased the I-box to the 3 rooms and increased the ducts to 7” flex. Installed balancing dampers in all the ducts and performed an airflow balancing of the home. Cleared, flushed and treated the condensate drain. Washed out the condenser and verified electrical and refrigerant charge. The system is opening at this time.
Installed Carrier heat pump system. Installed Ecobee thermostat. Installed new secondary drain pan. Rebuilt and insulated condensate drain line. Installed SS2 and SS3 safety switches. Cleared drain and verified operation. Built new supply and return plenum and re-attached ductwork. Sealed all connections with mastic air lock. Replaced disconnect and whip at outdoor unit. Replaced breaker going to outdoor unit.
We're thrilled to hear that our heating and cooling service exceeded your expectations. Thanks for the kind words!
Performed semiannual maintenance on one inverter heat pump unit and one mini split system. Inspected all Performance, Mechanical and Safety Systems. Tested and verified all mechanical components were operating within manufacture’s specifications for operation. Also verified all surge protection devices on the unit were on and protecting as designed. Verified the Stage 3 Breathe Easy System in the air handler in the attic is on and operating and keeping the indoor coil clean.
We're so happy to hear that our heating and cooling service met your needs. Thanks for the positive review!
Performed semiannual maintenance on one heat pump cooling system. Inspected all Performance, Mechanical and Safety Systems. Homeowner mentioned that the water safety switch coming off the internal drain pan would sometimes get water inside it, so he would tilt it upwards to help keep the system running. During my inspection, I found that the internal drain pan had some standing water inside due to there being gunk that had formed near and around the drain ports. Cleaned and cleared the primary drain line and the internal drain pan. Also added drain treatment into the pan and line, along with installing a union between the p-trap and the air handler to allow for cleaning of the line coming out of the air handler. Verified all other mechanical components were operating within manufacture’s specifications for operation. Everything is working at this time.
Installed new TXV in upstairs closet air handler. Removed previous filter drier and installed a new bi-flow filter dryer. Pressure tested system and performed a leak check. Pulled a deep vacuum and verified charge per data tag. Flushed drain line and varied zoning operation. Everything is working at this time.
Performed AC cool check on two systems. Checked electrical, mechanical, safety, and performance of the systems. The air handlers and blower wheels are clean. The electrical wiring is tight and in good condition. Drain lines were cleared and flow tested with water. The drain lines were then treated. The condenser fan motor on the Carrier condenser is showing signs of overheating. The capacitor is within value and the refrigerant charge is within spec. The Trane condenser is a variable speed inverter unit. The system is in good condition and the refrigerant charge is within factory spec. The condenser coils were cleaned. No other major issues were found.
nstalled Carrier gas system for game room. Installed propane conversion kit. Installed new supply and return plenums and sealed all connections with mastic air lock. Reused zoning equipment and thermostats. Flipped orientation of system for better access. Replaced secondary drain pan. Rebuilt and insulated primary and secondary drain lines. Cleared, treated and verified drain operation. Pressure tested and pulled a vacuum on the copper line set. Replaced disconnect and whip for outdoor system. Weighed in charge to meet manufacturers specifications. Replaced supply plenum for system above garage and sealed all connections with mastic air lock.
Performed semiannual maintenance on two heat pump cooling units. Inspected all Performance, Mechanical and Safety Systems. I did note on the system that services the master bedroom and the upstairs area, the outdoor run capacitor has failed below value, which is causing the condenser fan motor to pull more electricity than designed. Verified the Stage 3 Breathe Easy UV lights on the Kitchen side system are operating as designed. We also decided to change out the run capacitor on the master bedroom system. I installed a new capacitor and tested the system. Everything is working at this time.
Performed semiannual maintenance on two Lennox cooling systems. Inspected all Performance, Mechanical and Safety systems. On the upstairs HVAC system, I found that the unit was flat (empty) on R-410A. I used my electronic leak detector and then soap bubble leak detection solution to pinpoint a large rupture on the indoor coil piping. I also found that the secondary pan for the downstairs HVAC system is extremely rusted out. I recommend replacing the upstairs coil and recharging the system back to factory specifications. I also recommend replacing the emergency drain pan on the downstairs system to ensure in the event of a drainage overflow that no water leaks through the ceiling and causes sheetrock damage to the upstairs area. Did verify that the REME Halo Air Purifiers were on and operating during our visit.
Replacement of both condenser fan motors and the capacitor for the bedroom system. I arrived at the home and immediately got to work. I replaced the condenser fan motor on the main house system and tested it. It came on and ran properly. I then moved to the master bedroom system and replaced the motor as well as the capacitor. I tested the system, and it came on and ran immediately. The systems are in good working order. Systems are in working order at completion of appointment.
Replacement of both condenser fan motors and the capacitor for the bedroom system. I arrived at the home and immediately got to work. I replaced the condenser fan motor on the main house system and tested it. It came on and ran properly. I then moved to the master bedroom system and replaced the motor as well as the capacitor. I tested the system, and it came on and ran immediately. The systems are in good working order. Systems are in working order at completion of appointment.
Replacement of both condenser fan motors and the capacitor for the bedroom system. I arrived at the home and immediately got to work. I replaced the condenser fan motor on the main house system and tested it. It came on and ran properly. I then moved to the master bedroom system and replaced the motor as well as the capacitor. I tested the system, and it came on and ran immediately. The systems are in good working order. Systems are in working order at completion of appointment.
Replacement of both condenser fan motors and the capacitor for the bedroom system. I arrived at the home and immediately got to work. I replaced the condenser fan motor on the main house system and tested it. It came on and ran properly. I then moved to the master bedroom system and replaced the motor as well as the capacitor. I tested the system, and it came on and ran immediately. The systems are in good working order. Systems are in working order at completion of appointment.
Performed semiannual maintenance on two heat pump cooling systems. Inspected all Performance, Mechanical and Safety Systems. When entering the attic, I found that the upstairs HVAC system had a drainage overflow into the secondary drain pan due to a clogged-up drain line that attaches into the upstairs bathroom sink. Cleared the drainage restriction in the drain line and treated with our drainage treatment. Also did the same for the downstairs HVAC system. Spoke with homeowner about having water safety switches installed on both units to avoid water damage from a drain clog; he agreed. Installed switches and programmed the wall controller for the switches to shutdown unit in the event of a drain blockage. Verified everything was operating within manufacture’s specifications for operation.
Replaced the upstairs system blower motor. While replacing the motor I cleaned the blower wheel and the housing. I cycled power at the thermostat and confirmed the blower motor was working. Refrigerant levels are within spec. No other major issues were found. System is operational at this time.
Thank you for taking the time to leave such a positive review! We're glad to hear you had a great experience with us.
Installed new 4-ton Carrier heat pump system. Installed new Ecobee Lite thermostat. Rebuilt and insulated condensate drain line. Added SS2 and SS3 safety float switches. Installed new filter dryer, pressure tested with dry nitrogen and pulled a vacuum on copper line set. Replaced the condenser pad. Replaced the disconnect and ran the low voltage in Seal-Tite. Replaced both supply and return plenums and sealed with a mastic airlock. Replaced the RFG in the hallway. Charged system to factory spec and performed a benchmark. System is working properly at time of departure.
Upstairs HVAC System: On arrival, I turned the thermostat to cool mode and verified the indoor blower motor was running. I went outside and found that the outdoor heat pump was not running. Inspected the defrost board and found the board to have failed. I was able to test the outdoor unit and verified both heating and cooling operation. Went into the attic to inspect the electrical system and found the primary water safety switch has failed and therefore will not turn off low voltage power. Recommended replacement of the defrost board and installation of a new primary water safety switch. I installed a new outdoor defrost board and a new water safety switch at the indoor air handler. Installed new wiring terminal connections at the air handler to ensure a proper and secure fit. Tested all systems and verified operation. Everything is working at this time.
We are so grateful for your 5-star review. Thanks for sharing your rating with us and the community.
Performed heating maintenance on one heat pump system. Checked all electrical, mechanical and performance of the system. Cleared and treated the drain line and washed the outdoor coil. As I was checking, refrigerant pressures, I noticed that the compressor was not working and had shut off on thermal lockout.I cooled off the compressor and I found that the compressor start assist had failed the compressor was pulling 98 amps on start. I installed new start assist. Start amps are at 35 rated for 95. The compressor running amps are at 12 rated for 15 maximum. I cycled power and the system is now working at this time.
Thanks for leaving us such a wonderful review. We are glad that you loved our services, our dedicated staff will be pleased to learn of your high praise.