Since 1988, residents of Dripping Springs, TX have trusted Garner Heating & Air Conditioning to provide professional work and outstanding service for all of their HVAC needs. If you're looking for a provider you can count on, call today!
Some of the symptoms of bad indoor air quality in your Dripping Springs home are:
- Dry throat, nose and eyes.
- Dry or irritated skin.
- Increased allergies indoors.
Bad indoor air quality can also cause your home issues, such as mold growth, due to excessive humidity levels. To find out more about improving the indoor air quality of your home, contact us today.
It costs around $350-$3500 to repair a home air conditioner in Dripping Springs. Some things that can cause the price of the repair to vary include:
- How extensive the repair is.
- What type of repair is required.
- Whether replacement parts are needed.
Some repairs can be fairly inexpensive, whereas refrigerant leaks can be expensive due to the cost to replace the refrigerant in your AC system. To get your home air conditioner repaired, call us today.
Yes, AC tune ups are worth it in Dripping Springs. Some of the benefits of having your AC unit tuned up are:
- Your AC unit runs more smoothly.
- Your AC unit uses less energy.
- Your AC unit breaks down less.
Another benefit to having your air conditioner tuned up is that it will require less repairs and cool your home better. To get the best results, you should have your AC unit tuned up at least once a year. To get your AC unit tuned up, give us a call today!
There could be a number of issues with your air conditioner that is causing it to blow hot air in your home near Dripping Springs TX. Try troubleshooting a few common reasons first before calling a technician:
- Turn the thermostat to AUTO if it was set to ON so that the unit can complete a full cooling cycle.
- Change the air filter in order for the air to be able to circulate properly throughout your home.
- Clean the outdoor unit so that the unit can expel warm air from your home.
- Check the circuit breaker in case it has tripped which will cause it to still operate but not produce cool air.
If you have checked these items and your unit is still not cooling the house, your next step should be a call to a professional. The expert technicians at Garner can diagnose any AC repair issue and fix it effectively at an affordable rate. Contact us online today for an appointment.
On average, in the Dripping Springs TX area you can expect to pay anywhere from $250 - $1,500 to a freon leak repair. It can be hard to estimate the cost of a freon leak in an air conditioner as the price depends almost entirely on where the leak is located and the size of it. A hard to find severe leak could take technicians all day to repair, which will increase costs of labor.
For a more accurate estimate on repair services, the knowledgeable team members at Garner are happy to help. Contact us today to learn more about freon leaks and their costs!
An AC compressor works to move refrigerant throughout the unit to ultimately produce the cool air for your home. When it goes bad, there are a few signs you should be on the lookout for:
- Weird noises.
- Unit will not start.
- Air is not cooling.
- Breaker keeps tripping.
- Less air coming from vents.
Do you suspect your compressor is going bad? Contact Garner today for precise reliable AC repair services!
If you'd like to know what your neighbors in Dripping Springs, TX think, just check out their reviews below!
Recent Jobs and Reviews in Dripping Springs, TX
Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting high levels of customer satisfaction and appreciation. Customers consistently express gratitude for the professionalism, punctuality, and expertise demonstrated by the service team. There is a strong recurring theme of technicians being knowledgeable, thorough, and excellent communicators who take time to explain issues, answer questions, and provide helpful advice without applying undue pressure. Many reviewers highlight the courteous and respectful nature of the staff, noting details such as wearing shoe covers, protecting work areas, and leaving spaces clean after completion. Timeliness emerges as another dominant positive trend, with numerous mentions of technicians arriving on time or even early, completing work efficiently, and providing same-day service. Customers frequently express confidence in the quality of work performed, even under challenging conditions like extreme heat, and many indicate strong loyalty, stating they will use the service again and recommend it to family and friends. The emotional tone is enthusiastic and appreciative, with reviewers describing their experiences as "great," "excellent," "fantastic," and "outstanding." Overall, the reviews convey a sense of trust, reliability, and exceptional customer care that has clearly resonated with clients.
Dripping Springs, TX at a glance
Garner Heating & Air Conditioning Inc has completed 25 jobs in Dripping Springs, TX between July 2023 and July 2024.
The most recent job was on July 1, 2024.
Garner Heating & Air Conditioning Inc has completed 17 jobs in Dripping Springs, TX in the last 12 months. The first job there was in September 2018.
Our Local Reviews by City
- Austin, TX (78)
- Buda, TX (331)
- Canyon Lake, TX (5)
- Creedmoor, TX (4)
- Dale, TX (1)
- Driftwood, TX (29)
- Dripping Springs, TX (26)
- Hays, TX (1)
- Kingsbury, TX (1)
- Kyle, TX (480)
- Lockhart, TX (15)
- Manchaca, TX (9)
- Martindale, TX (14)
- Maxwell, TX (3)
- Mountain City, TX (26)
- New Braunfels, TX (13)
- Niederwald, TX (15)
- San Marcos, TX (157)
- Seguin, TX (3)
- Uhland, TX (2)
- West Lake Hills, TX (1)
- Wimberley, TX (104)
- Woodcreek, TX (4)
Job Locations and Reviews
Performed semiannual maintenance on one heat pump cooling system. Inspected all Performance, Mechanical and Safety Systems. Homeowner mentioned that the water safety switch coming off the internal drain pan would sometimes get water inside it, so he would tilt it upwards to help keep the system running. During my inspection, I found that the internal drain pan had some standing water inside due to there being gunk that had formed near and around the drain ports. Cleaned and cleared the primary drain line and the internal drain pan. Also added drain treatment into the pan and line, along with installing a union between the p-trap and the air handler to allow for cleaning of the line coming out of the air handler. Verified all other mechanical components were operating within manufacture’s specifications for operation. Everything is working at this time.
Installed new TXV in upstairs closet air handler. Removed previous filter drier and installed a new bi-flow filter dryer. Pressure tested system and performed a leak check. Pulled a deep vacuum and verified charge per data tag. Flushed drain line and varied zoning operation. Everything is working at this time.
Performed AC cool check on two systems. Checked electrical, mechanical, safety, and performance of the systems. The air handlers and blower wheels are clean. The electrical wiring is tight and in good condition. Drain lines were cleared and flow tested with water. The drain lines were then treated. The condenser fan motor on the Carrier condenser is showing signs of overheating. The capacitor is within value and the refrigerant charge is within spec. The Trane condenser is a variable speed inverter unit. The system is in good condition and the refrigerant charge is within factory spec. The condenser coils were cleaned. No other major issues were found.
nstalled Carrier gas system for game room. Installed propane conversion kit. Installed new supply and return plenums and sealed all connections with mastic air lock. Reused zoning equipment and thermostats. Flipped orientation of system for better access. Replaced secondary drain pan. Rebuilt and insulated primary and secondary drain lines. Cleared, treated and verified drain operation. Pressure tested and pulled a vacuum on the copper line set. Replaced disconnect and whip for outdoor system. Weighed in charge to meet manufacturers specifications. Replaced supply plenum for system above garage and sealed all connections with mastic air lock.
Performed semiannual maintenance on two heat pump cooling units. Inspected all Performance, Mechanical and Safety Systems. I did note on the system that services the master bedroom and the upstairs area, the outdoor run capacitor has failed below value, which is causing the condenser fan motor to pull more electricity than designed. Verified the Stage 3 Breathe Easy UV lights on the Kitchen side system are operating as designed. We also decided to change out the run capacitor on the master bedroom system. I installed a new capacitor and tested the system. Everything is working at this time.
Performed semiannual maintenance on two Lennox cooling systems. Inspected all Performance, Mechanical and Safety systems. On the upstairs HVAC system, I found that the unit was flat (empty) on R-410A. I used my electronic leak detector and then soap bubble leak detection solution to pinpoint a large rupture on the indoor coil piping. I also found that the secondary pan for the downstairs HVAC system is extremely rusted out. I recommend replacing the upstairs coil and recharging the system back to factory specifications. I also recommend replacing the emergency drain pan on the downstairs system to ensure in the event of a drainage overflow that no water leaks through the ceiling and causes sheetrock damage to the upstairs area. Did verify that the REME Halo Air Purifiers were on and operating during our visit.
Replacement of both condenser fan motors and the capacitor for the bedroom system. I arrived at the home and immediately got to work. I replaced the condenser fan motor on the main house system and tested it. It came on and ran properly. I then moved to the master bedroom system and replaced the motor as well as the capacitor. I tested the system, and it came on and ran immediately. The systems are in good working order. Systems are in working order at completion of appointment.
Replacement of both condenser fan motors and the capacitor for the bedroom system. I arrived at the home and immediately got to work. I replaced the condenser fan motor on the main house system and tested it. It came on and ran properly. I then moved to the master bedroom system and replaced the motor as well as the capacitor. I tested the system, and it came on and ran immediately. The systems are in good working order. Systems are in working order at completion of appointment.
Replacement of both condenser fan motors and the capacitor for the bedroom system. I arrived at the home and immediately got to work. I replaced the condenser fan motor on the main house system and tested it. It came on and ran properly. I then moved to the master bedroom system and replaced the motor as well as the capacitor. I tested the system, and it came on and ran immediately. The systems are in good working order. Systems are in working order at completion of appointment.
Replacement of both condenser fan motors and the capacitor for the bedroom system. I arrived at the home and immediately got to work. I replaced the condenser fan motor on the main house system and tested it. It came on and ran properly. I then moved to the master bedroom system and replaced the motor as well as the capacitor. I tested the system, and it came on and ran immediately. The systems are in good working order. Systems are in working order at completion of appointment.
Performed semiannual maintenance on two heat pump cooling systems. Inspected all Performance, Mechanical and Safety Systems. When entering the attic, I found that the upstairs HVAC system had a drainage overflow into the secondary drain pan due to a clogged-up drain line that attaches into the upstairs bathroom sink. Cleared the drainage restriction in the drain line and treated with our drainage treatment. Also did the same for the downstairs HVAC system. Spoke with homeowner about having water safety switches installed on both units to avoid water damage from a drain clog; he agreed. Installed switches and programmed the wall controller for the switches to shutdown unit in the event of a drain blockage. Verified everything was operating within manufacture’s specifications for operation.
Replaced the upstairs system blower motor. While replacing the motor I cleaned the blower wheel and the housing. I cycled power at the thermostat and confirmed the blower motor was working. Refrigerant levels are within spec. No other major issues were found. System is operational at this time.
Installed new 4-ton Carrier heat pump system. Installed new Ecobee Lite thermostat. Rebuilt and insulated condensate drain line. Added SS2 and SS3 safety float switches. Installed new filter dryer, pressure tested with dry nitrogen and pulled a vacuum on copper line set. Replaced the condenser pad. Replaced the disconnect and ran the low voltage in Seal-Tite. Replaced both supply and return plenums and sealed with a mastic airlock. Replaced the RFG in the hallway. Charged system to factory spec and performed a benchmark. System is working properly at time of departure.
Upstairs HVAC System: On arrival, I turned the thermostat to cool mode and verified the indoor blower motor was running. I went outside and found that the outdoor heat pump was not running. Inspected the defrost board and found the board to have failed. I was able to test the outdoor unit and verified both heating and cooling operation. Went into the attic to inspect the electrical system and found the primary water safety switch has failed and therefore will not turn off low voltage power. Recommended replacement of the defrost board and installation of a new primary water safety switch. I installed a new outdoor defrost board and a new water safety switch at the indoor air handler. Installed new wiring terminal connections at the air handler to ensure a proper and secure fit. Tested all systems and verified operation. Everything is working at this time.
Performed heating maintenance on one heat pump system. Checked all electrical, mechanical and performance of the system. Cleared and treated the drain line and washed the outdoor coil. As I was checking, refrigerant pressures, I noticed that the compressor was not working and had shut off on thermal lockout.I cooled off the compressor and I found that the compressor start assist had failed the compressor was pulling 98 amps on start. I installed new start assist. Start amps are at 35 rated for 95. The compressor running amps are at 12 rated for 15 maximum. I cycled power and the system is now working at this time.
Performed heating maintenance on two heat pump systems. Checked all electrical, mechanical and performance of both systems. Both blower wheels have microbial growth on them. I informed the homeowner of what I found and presented options for cleaning them, but she declined repairs at this time. No other major issues were found, and both systems are operational at this time. See attached checklists for full tune-up details.
Performed heating maintenance on a heat pump system. Checked all electrical, mechanical and performance of the system. Cleared and treated drain line and washed the outdoor coil. I did find the blower wheel covered in microbial growth. I informed the homeowner and presented options for replacement of the blower wheel; he chose to have it replaced. Replaced blower wheel, cycled power at the thermostat and confirmed the system is working.
Performed heating maintenance on one heat pump system. Checked all electrical, mechanical and performance of the system. Cleared and treated the drain line and washed the outdoor coil. No major issues were found. See attached checklist for full tune-up details. I offered nice to have items to the customer and he chose to have a surge protection device added to the air handler and condenser unit at this time. I installed both surge protectors and cycled power. Everything is working at this time.
Performed heat check on one heat pump and one mini split system. The air purifier on main home system is operational. The customer had left it unplugged due to the smell associated with a running purifier. I turned it on and checked the function and then unplugged it per customer request. Main house heat pump has a condenser fan motor that is showing signs of overheating. No other major issues were found.
Performed semiannual maintenance on two heating systems. Inspected all Performance, Mechanical and Safety Systems. Inside the main house I changed one homeowner supplied PerfectFit filter. Cleared out the drain line (noticed there was some grass inside the drainpipe at the exterior exit of the drain). Tested both the outdoor heat pump and indoor three stage heating elements. Found all systems to be operating within manufacture’s specifications for operation. Inspected all systems on the guest house heating system. Did note on the outdoor condenser fan motor that there are signs of overheating. Electrical power draw is within manufacture’s specifications for operation. Changed one homeowner supplied 18x30x1 filter. Verified everything was operating within manufacture’s specifications for operation.
Performed semiannual maintenance on two dual fuel systems. Inspected all Performance, Mechanical and Safety Systems. Did adjust fuel pressure to match manufacturer specifications for operation. Inspected the outdoor heat pump system and confirmed defrost mode is operating as design. Changed two homeowner supplied filters for the electrostatic filter base inside the attic. Everything is working at this time.
Installed new Carrier 3-ton heat pump system. Installed new Ecobee Pro thermostat. Rebuilt and insulated condensate drain line. Added SS2 and SS3 safety float switches. Replaced secondary drain pan. Installed new filter dryer, pressure tested with dry nitrogen and pulled a vacuum on the copper line set. Replaced the disconnect and ran the low voltage in Seal-Tite. Replaced both supply and return plenums and sealed with mastic airlock. Charged system to factory spec. System is working properly at time of departure.
Performed service diagnostic. Diagnostic found that the condensate drain line was clogged. Water had back up and tripped the safety switch. Options for repair were presented to the customer and they chose to have a drain service completed today and sign up for our semiannual maintenance plan. The first of two visits will be completed this Fall/Winter. Drain line was cleared and flow tested with water. Drain line was treated. System was function checked and was running at the time of departure.
Performed service diagnostic. Diagnostic found that the capacitor on the condenser unit was depleted and couldn’t reliably start the compressor. Options for repair were presented to the customer and they chose to have the capacitor replaced today. Capacitor was replaced and the system was function checked. System was running at the time of departure.
Performed two AC tune-ups. Cleared and treated drain lines. Condenser coils clean. No major issues found.