Get the Best HVAC Service
Garner Heating & Air Conditioning offers over 35 years experience in servicing, repairing, and replacing your HVAC system, so let us take that pressure off of you. We'll do the work - you enjoy the comfort. Call 512-392-2000 for all your HVAC replacement, repair and maintenance service near Kyle, TX or contact us online with any questions.
HVAC Replacement Service in Kyle, TX
Like all major appliances in your home, your HVAC system is made up of countless parts all working in concert to provide your home welcoming comfort. Those parts need to be properly maintained and cared for so you always have the warming heat or refreshing cool you need. But who has the time to do that themselves?
If your AC unit is more than 10-15 years old, replacing it could save you money on energy bills and repair costs. Upgrading to a new, energy-efficient system can improve comfort, reduce maintenance, and lower your electricity usage.
When Should You Replace Your HVAC System?
- Your AC needs frequent, costly repairs.
- Your unit is over 10 years old and struggles to cool your home.
- Energy bills have steadily increased despite regular maintenance.
- Your home has uneven temperatures from room to room.
What Size AC Unit Do You Need?
The right AC size depends on your home’s square footage, insulation, and layout. An oversized unit may cool too quickly without removing humidity, while an undersized unit will struggle to keep up. Our HVAC experts perform a full evaluation to recommend the best system for your home.
Expert Air Conditioning Repair in Kyle, TX
If your AC isn’t keeping up with the heat, it might be time for repairs. Common signs your air conditioner needs servicing include:
- Warm air blowing from vents – This could indicate low refrigerant levels or a failing compressor.
- Unusual noises – Grinding, squealing, or rattling sounds could mean parts are loose or worn out.
- High energy bills – If your energy costs are rising, your system may be struggling to run efficiently.
- Frequent cycling – If your AC turns on and off repeatedly, it could be a sign of thermostat issues or restricted airflow.
How Long Does AC Repair Take?
Most AC repairs can be completed within a few hours, depending on the problem. Our team arrives with the tools and parts needed to diagnose and fix issues quickly. If a major repair is needed, we’ll discuss your options and provide transparent pricing before starting any work.
Heating and Cooling Service FAQs
If your air conditioner freezes, follow these steps to get your unit functioning again:
- Turn off the unit from the breaker. This will allow the unit to thaw. FYI, thawing could take an entire day.
- Do not remove the ice by hand to avoid damaging the unit.
- After thawing, dry the coils by turning back on your unit but on the fan setting only. This helps circulate air and dry the coils quickly.
- Turn the AC back on to see if it operates without freezing over.
Homeowners can anticipate paying between $100 - $500 for air conditioner repairs.
A faulty drain pan, loose connections, or worn-out components can lead to costly water damage. Catching minor issues early prevents major headaches down the road.
The cost to replace a heating and cooling system typically ranges from $5,000 to $15,000, depending on factors like the size of the home, system efficiency, and installation requirements.
If it's Garner, It's Guaranteed
We know it can be difficult to bring someone into your home and trust them to do the work right. That's why Garner offers at 100% satisfaction guarantee on all the service we perform. We want you to be certain, before we even step through the door, that you're going to get the right solutions, at the right price, with the right quality.
Give us a call at 512-392-2000 and make us your partner in comfort today. Of course, the best opinion on our work comes from your neighbors. See what they have to say about Garner Heating & Air Conditioning below.
Recent Jobs and Reviews in Kyle, TX
Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting high levels of customer satisfaction and appreciation. Customers consistently express gratitude for the professionalism, punctuality, and expertise demonstrated by the service team. There is a strong recurring theme of technicians being knowledgeable, thorough, and excellent communicators who take time to explain issues, answer questions, and provide helpful advice without applying undue pressure. Many reviewers highlight the courteous and respectful nature of the staff, noting details such as wearing shoe covers, protecting work areas, and leaving spaces clean after completion. Timeliness emerges as another dominant positive trend, with numerous mentions of technicians arriving on time or even early, completing work efficiently, and providing same-day service. Customers frequently express confidence in the quality of work performed, even under challenging conditions like extreme heat, and many indicate strong loyalty, stating they will use the service again and recommend it to family and friends. The emotional tone is enthusiastic and appreciative, with reviewers describing their experiences as "great," "excellent," "fantastic," and "outstanding." Overall, the reviews convey a sense of trust, reliability, and exceptional customer care that has clearly resonated with clients.
Kyle, TX at a glance
Garner Heating & Air Conditioning Inc has completed 15 jobs in Kyle, TX between June 2022 and July 2022.
The most recent job was on July 21, 2022.
Garner Heating & Air Conditioning Inc has completed 527 jobs in Kyle, TX in the last 12 months. The first job there was in July 2018.
Our Local Reviews by City
- Austin, TX (78)
- Buda, TX (331)
- Canyon Lake, TX (5)
- Creedmoor, TX (4)
- Dale, TX (1)
- Driftwood, TX (29)
- Dripping Springs, TX (26)
- Hays, TX (1)
- Kingsbury, TX (1)
- Kyle, TX (480)
- Lockhart, TX (15)
- Manchaca, TX (9)
- Martindale, TX (14)
- Maxwell, TX (3)
- Mountain City, TX (26)
- New Braunfels, TX (13)
- Niederwald, TX (15)
- San Marcos, TX (157)
- Seguin, TX (3)
- Uhland, TX (2)
- West Lake Hills, TX (1)
- Wimberley, TX (104)
- Woodcreek, TX (4)
Job Locations and Reviews
Performed service diagnostic. Diagnostic found that the capacitor on the condenser unit had failed. Options for repair were presented to customer and they chose to have the capacitor replaced and join our maintenance plan. Repair was completed. Electrical disconnect confirmed in and on. System was running at the time of departure.
Diagnosed a clog in the primary drain line. Gave Robert options and he chose for me to move forward with repairs. Treated drain line and cleared system. Checked coil drain pan for any debris and found none.
The customer stated that the system would start hot and then get cold after a few seconds. After looking over the system I diagnosed that the system had a clogged drain which was short cycling the system. Also, the condenser fan motor needed to be replaced and the condenser coils needed to be cleaned. Gave the customer her options for repairs and she chose to have the drain cleared, have the fan motor replaced, and sign up for our maintenance plan. I completed the repairs and performed the cool check. Please see attached checklist for full tune-up details.
Performed AC cool check. Checked electrical, mechanical, safety, and performance of the system. No major issues were found. Drain line cleared and treated. Condenser coil cleaned. Electrical disconnect confirmed in and on. System was running at the time of departure.
Installed new Carrier 4-ton gas system. Replaced both supply and return plenums and sealed all connections with airlock mastic. Replaced inline filter dryer, pressure tested with dry nitrogen, and pulled a vacuum on copper line set. Rebuilt condensate drain line and insulated it. Installed SS-2 and SS-3 safety float switches. Replaced secondary drain pan. Rebuilt gas line to the furnace. Replaced condenser pad. Put new insulation on copper outside. Sealed outdoor penetration with spray foam. Charged system to factory specs. System is working properly at this time.
Performed the AC tune-up. While performing the inspection I did find mold growth starting inside the air handler. I showed the client and informed him of his options. He chose to monitor it for now. I also found that the battery cap is failing, and he said he is going to check with his warranty company before they have us replace it. The system is working at this time.
Performed semiannual maintenance on two cooling systems. Flushed and treated all primary drains. Inspected all performance, mechanical and safety systems. Changed two air protection systems with homeowner supplied filters. Verified all Ultra-Violet Bacteria Prevention Systems are operating within manufacture’s specifications. On the upstairs’ cooling system, we did find the Refrigerant Pressure Control System to be failing at this time, causing an extreme loss in cooling capacity, and allowing the Heat Transfer Media Coil to freeze up while running. Recommend repair to return system back to 100% cooling capacity of the upstairs but customer asked that we email the estimate.
Diagnosed that the control board for the condenser has failed. System was no longer able to communicate with the outdoor system. Gave the client her options and she chose to replace the board. Changed out control board at condenser and tested system. Performed cool check. No other major issues were found. Cleared and treated drain. System is operational at this time.
Performed service diagnostic. Diagnostic found that the primary condensate drain line had clogged. Water had backed up and spilled outside the unit. Options for repair were presented to customer and he chose to have the drain cleared and treated. Repair was completed. Electrical disconnect confirmed in and on. System was running at the time of departure.
Performed AC cool check. Checked electrical, mechanical, safety, and performance of the system. No major issues were found. Drain line cleared and treated. Condenser coil cleaned. Electrical disconnect confirmed in and on. System was running at the time of departure.
Performed AC cool check. Checked electrical, mechanical, safety, and performance of the system. Blower wheel had mold/mildew growing on it and several spots of mold were found inside the air handler. No other major issues were found. Drain line cleared and treated. Condenser coil cleaned. Options for repair were presented to customer and declined repairs at this time but would like the estimates emailed. Electrical disconnect confirmed in and on. System was running at the time of departure.
Replaced blower motor inside furnace with new replacement motor. Ran new motor through three system cycles and then ran airflow verification test on system. Through testing there were no reported faults and no issues surfaced. System is operational at this time and thermostat is set to customer preferences. Disconnect in.
Installed new scroll compressor in outdoor unit. Removed refrigerant and installed new line filter dryer. Pressure tested system for extensive leak check and pulled deep vacuum. Weighed in factory charge. System operating at this time. Also washed off condensing coil and installed new wiring harness.
Performed service diagnostic. Diagnostic found that the primary condensate drain line was clogged. Water was backing up into the unit and spilling out of the primary drain pan. Safety switch installed in the system was not operating. Options for repair were presented to customer and they chose to have the drain line cleared and treated. Repair was completed. Electrical disconnect confirmed in and on. System was running at the time of departure.
Performed service diagnostic. Diagnostic found that the compressor was not running. Compressor was not running because the condenser capacitor had failed. Options for repair were presented to customer and they chose to have the capacitor replaced. Repair was completed. Electrical disconnect confirmed in and on. System was running at the time of departure.