Get the Best HVAC Service
Garner Heating & Air Conditioning offers over 35 years experience in servicing, repairing, and replacing your HVAC system, so let us take that pressure off of you. We'll do the work - you enjoy the comfort. Call 512-392-2000 for all your HVAC replacement, repair and maintenance service near Kyle, TX or contact us online with any questions.
HVAC Replacement Service in Kyle, TX
Like all major appliances in your home, your HVAC system is made up of countless parts all working in concert to provide your home welcoming comfort. Those parts need to be properly maintained and cared for so you always have the warming heat or refreshing cool you need. But who has the time to do that themselves?
If your AC unit is more than 10-15 years old, replacing it could save you money on energy bills and repair costs. Upgrading to a new, energy-efficient system can improve comfort, reduce maintenance, and lower your electricity usage.
When Should You Replace Your HVAC System?
- Your AC needs frequent, costly repairs.
- Your unit is over 10 years old and struggles to cool your home.
- Energy bills have steadily increased despite regular maintenance.
- Your home has uneven temperatures from room to room.
What Size AC Unit Do You Need?
The right AC size depends on your home’s square footage, insulation, and layout. An oversized unit may cool too quickly without removing humidity, while an undersized unit will struggle to keep up. Our HVAC experts perform a full evaluation to recommend the best system for your home.
Expert Air Conditioning Repair in Kyle, TX
If your AC isn’t keeping up with the heat, it might be time for repairs. Common signs your air conditioner needs servicing include:
- Warm air blowing from vents – This could indicate low refrigerant levels or a failing compressor.
- Unusual noises – Grinding, squealing, or rattling sounds could mean parts are loose or worn out.
- High energy bills – If your energy costs are rising, your system may be struggling to run efficiently.
- Frequent cycling – If your AC turns on and off repeatedly, it could be a sign of thermostat issues or restricted airflow.
How Long Does AC Repair Take?
Most AC repairs can be completed within a few hours, depending on the problem. Our team arrives with the tools and parts needed to diagnose and fix issues quickly. If a major repair is needed, we’ll discuss your options and provide transparent pricing before starting any work.
Heating and Cooling Service FAQs
If your air conditioner freezes, follow these steps to get your unit functioning again:
- Turn off the unit from the breaker. This will allow the unit to thaw. FYI, thawing could take an entire day.
- Do not remove the ice by hand to avoid damaging the unit.
- After thawing, dry the coils by turning back on your unit but on the fan setting only. This helps circulate air and dry the coils quickly.
- Turn the AC back on to see if it operates without freezing over.
Homeowners can anticipate paying between $100 - $500 for air conditioner repairs.
A faulty drain pan, loose connections, or worn-out components can lead to costly water damage. Catching minor issues early prevents major headaches down the road.
The cost to replace a heating and cooling system typically ranges from $5,000 to $15,000, depending on factors like the size of the home, system efficiency, and installation requirements.
If it's Garner, It's Guaranteed
We know it can be difficult to bring someone into your home and trust them to do the work right. That's why Garner offers at 100% satisfaction guarantee on all the service we perform. We want you to be certain, before we even step through the door, that you're going to get the right solutions, at the right price, with the right quality.
Give us a call at 512-392-2000 and make us your partner in comfort today. Of course, the best opinion on our work comes from your neighbors. See what they have to say about Garner Heating & Air Conditioning below.
Recent Jobs and Reviews in Kyle, TX
Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting high levels of customer satisfaction and appreciation. Customers consistently express gratitude for the professionalism, punctuality, and expertise demonstrated by the service team. There is a strong recurring theme of technicians being knowledgeable, thorough, and excellent communicators who take time to explain issues, answer questions, and provide helpful advice without applying undue pressure. Many reviewers highlight the courteous and respectful nature of the staff, noting details such as wearing shoe covers, protecting work areas, and leaving spaces clean after completion. Timeliness emerges as another dominant positive trend, with numerous mentions of technicians arriving on time or even early, completing work efficiently, and providing same-day service. Customers frequently express confidence in the quality of work performed, even under challenging conditions like extreme heat, and many indicate strong loyalty, stating they will use the service again and recommend it to family and friends. The emotional tone is enthusiastic and appreciative, with reviewers describing their experiences as "great," "excellent," "fantastic," and "outstanding." Overall, the reviews convey a sense of trust, reliability, and exceptional customer care that has clearly resonated with clients.
Kyle, TX at a glance
Garner Heating & Air Conditioning Inc has completed 15 jobs in Kyle, TX between September 2021 and October 2021.
The most recent job was on October 6, 2021.
Garner Heating & Air Conditioning Inc has completed 527 jobs in Kyle, TX in the last 12 months. The first job there was in July 2018.
Our Local Reviews by City
- Austin, TX (78)
- Buda, TX (331)
- Canyon Lake, TX (5)
- Creedmoor, TX (4)
- Dale, TX (1)
- Driftwood, TX (29)
- Dripping Springs, TX (26)
- Hays, TX (1)
- Kingsbury, TX (1)
- Kyle, TX (480)
- Lockhart, TX (15)
- Manchaca, TX (9)
- Martindale, TX (14)
- Maxwell, TX (3)
- Mountain City, TX (26)
- New Braunfels, TX (13)
- Niederwald, TX (15)
- San Marcos, TX (157)
- Seguin, TX (3)
- Uhland, TX (2)
- West Lake Hills, TX (1)
- Wimberley, TX (104)
- Woodcreek, TX (4)
Job Locations and Reviews
Performed further diagnostic on a Lennox system and found refrigerant leak at evaporator coil causing abnormal sounds and insufficient cooling. I presented customer with options, and they will discuss with the new owners about what option they would like.
When I arrived, I found that the breaker to the furnace was tripped. After speaking with the customer, he let me know that it happened after plugging a freezer into the outlet. I reset the breaker and unplugged the freezer, and everything came on. I also found the drain line was backed up and the customer chose to have it cleared at the basic level. After performing the basic level repair everything is draining properly at this time. Lastly, the refrigerant pressures were off however the customer wanted to hold off on fixing that repair due to it being a 16-year-old R-22 system. He said he would call us if it stopped working and look at replacement at that time.
Ducted the return side of the unit to the main return in fiber board. Rehung and strapped flex duct. Added 12x12x7 return into front bedroom and sealed all ductwork with mastic tape and air lock. Installed 25x25 media filter and checked system performance. Also installed 3 UV blue lights in coil and blower compartments. System working at this time.
Installed Carrier 4-ton, 2 stage system with variable speed dehumidification. Extended secondary drain line down to the ground for primary use. Added new safety switches and installed new line filter dryer. Pressure tested system for extensive leak check. Pulled deep vacuum and charged system to factory specs. Added new plenums and sealed pressure points with mastic tape and air lock. Installed new Ecobee thermostat and benchmarked system. System operational.
Performed diagnostic on a Lennox gas system and found primary drain obstruction Intermittently cutting off cooling circuit to the entire system. I presented the customer with options, and they have chosen to move forward with primary drain treatment. Primary drain has been treated and cleaned. System is now operational.
rip 1 - Performed diagnostic on a Carrier heat pump system and found outdoor voltage distribution system failure preventing cooling cycle. Presented customer with options and has chosen to move forward with voltage distribution system renovations. New voltage distribution system has been installed along with new battery capacitor and performance enhancement system to help prolong the life of air conditioner. While conducting the performance test I also found a refrigerant leak at the heat transfer media coil. Presented customer with options on replacing heat transfer media coil and they have chosen to move forward with Silver level coil replacement. Will return to complete repair. Trip 2 - New 2-ton evaporator coil has been installed, secured, and tested. Also performed a cleaning at interior of air handler and plumbing. Secured all wiring and added 4.11 pounds of refrigerant. System is now operational.
Found a short in the low voltage control wiring. I was able to use the existing wiring and make the repair. I replaced the fuse, and the system is operational however it is 21 years old and full of mold. The growth is so prolific that the only way to solve the issue is replacing the system. Our Comfort Consultant will reach out to schedule an appointment to discuss system replacement options.
Diagnosed a grounded compressor on the start winding. System is 18 years old and needs to be replaced. Our Comfort Consultant will reach out Monday to schedule an appointment
Diagnosed a clogged drain during initial inspection. I have cleared the drain and removed 5 gallons of water from the drain pan. The system is 17 years old, and it is showing its age. I spoke to Melissa and informed her that she needs to save up for a new system. System is operational at completion of service.
Performed system cleaning on Carrier heat pump system in attic. Added new SS-2 safety switch and cleared drain line. Added three UV lights to air handler and one REME Halo LED to supply plenum. Cut in two new 12x 12 RAFG to return chase. Replaced outdoor condenser fan motor as well as the battery capacitor and starter. Charged system to factory specs with R-410A refrigerant. System operating at this time.
Performed diagnostic on a straight electric mobile home application system and found 12-inch flex jumper duct to be pinched at three spots causing airflow restrictions to furthest room is home. Presented customer with options but they declined all options and will call their warranty company.
Performed diagnostic on a Goodman gas system and found primary drain line obstructed causing condensation water to accumulate in large drain pan. Also, at outdoor unit, I found condensing fan motor failure preventing cooling cycle. Presented customer with options and they have chosen to move forward with Platinum level condensing motor system renovations. New condensing fan motor and contactor have been installed, secured, and tested. Also disassembled and cleaned the condenser coils. Upon completion a performance test was completed, and system is now within parameters and operational.