Get the Best HVAC Service
Garner Heating & Air Conditioning offers over 35 years experience in servicing, repairing, and replacing your HVAC system, so let us take that pressure off of you. We'll do the work - you enjoy the comfort. Call 512-392-2000 for all your HVAC replacement, repair and maintenance service near Kyle, TX or contact us online with any questions.
HVAC Replacement Service in Kyle, TX
Like all major appliances in your home, your HVAC system is made up of countless parts all working in concert to provide your home welcoming comfort. Those parts need to be properly maintained and cared for so you always have the warming heat or refreshing cool you need. But who has the time to do that themselves?
If your AC unit is more than 10-15 years old, replacing it could save you money on energy bills and repair costs. Upgrading to a new, energy-efficient system can improve comfort, reduce maintenance, and lower your electricity usage.
When Should You Replace Your HVAC System?
- Your AC needs frequent, costly repairs.
- Your unit is over 10 years old and struggles to cool your home.
- Energy bills have steadily increased despite regular maintenance.
- Your home has uneven temperatures from room to room.
What Size AC Unit Do You Need?
The right AC size depends on your home’s square footage, insulation, and layout. An oversized unit may cool too quickly without removing humidity, while an undersized unit will struggle to keep up. Our HVAC experts perform a full evaluation to recommend the best system for your home.
Expert Air Conditioning Repair in Kyle, TX
If your AC isn’t keeping up with the heat, it might be time for repairs. Common signs your air conditioner needs servicing include:
- Warm air blowing from vents – This could indicate low refrigerant levels or a failing compressor.
- Unusual noises – Grinding, squealing, or rattling sounds could mean parts are loose or worn out.
- High energy bills – If your energy costs are rising, your system may be struggling to run efficiently.
- Frequent cycling – If your AC turns on and off repeatedly, it could be a sign of thermostat issues or restricted airflow.
How Long Does AC Repair Take?
Most AC repairs can be completed within a few hours, depending on the problem. Our team arrives with the tools and parts needed to diagnose and fix issues quickly. If a major repair is needed, we’ll discuss your options and provide transparent pricing before starting any work.
Heating and Cooling Service FAQs
If your air conditioner freezes, follow these steps to get your unit functioning again:
- Turn off the unit from the breaker. This will allow the unit to thaw. FYI, thawing could take an entire day.
- Do not remove the ice by hand to avoid damaging the unit.
- After thawing, dry the coils by turning back on your unit but on the fan setting only. This helps circulate air and dry the coils quickly.
- Turn the AC back on to see if it operates without freezing over.
Homeowners can anticipate paying between $100 - $500 for air conditioner repairs.
A faulty drain pan, loose connections, or worn-out components can lead to costly water damage. Catching minor issues early prevents major headaches down the road.
The cost to replace a heating and cooling system typically ranges from $5,000 to $15,000, depending on factors like the size of the home, system efficiency, and installation requirements.
If it's Garner, It's Guaranteed
We know it can be difficult to bring someone into your home and trust them to do the work right. That's why Garner offers at 100% satisfaction guarantee on all the service we perform. We want you to be certain, before we even step through the door, that you're going to get the right solutions, at the right price, with the right quality.
Give us a call at 512-392-2000 and make us your partner in comfort today. Of course, the best opinion on our work comes from your neighbors. See what they have to say about Garner Heating & Air Conditioning below.
Recent Jobs and Reviews in Kyle, TX
Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting high levels of customer satisfaction and appreciation. Customers consistently express gratitude for the professionalism, punctuality, and expertise demonstrated by the service team. There is a strong recurring theme of technicians being knowledgeable, thorough, and excellent communicators who take time to explain issues, answer questions, and provide helpful advice without applying undue pressure. Many reviewers highlight the courteous and respectful nature of the staff, noting details such as wearing shoe covers, protecting work areas, and leaving spaces clean after completion. Timeliness emerges as another dominant positive trend, with numerous mentions of technicians arriving on time or even early, completing work efficiently, and providing same-day service. Customers frequently express confidence in the quality of work performed, even under challenging conditions like extreme heat, and many indicate strong loyalty, stating they will use the service again and recommend it to family and friends. The emotional tone is enthusiastic and appreciative, with reviewers describing their experiences as "great," "excellent," "fantastic," and "outstanding." Overall, the reviews convey a sense of trust, reliability, and exceptional customer care that has clearly resonated with clients.
Kyle, TX at a glance
Garner Heating & Air Conditioning Inc has completed 15 jobs in Kyle, TX in August 2026.
The 10 customer reviews shown here average 5.0 out of 5.
The most recent job was on August 24, 2026.
Garner Heating & Air Conditioning Inc has completed 531 jobs in Kyle, TX in the last 12 months. The first job there was in July 2018.
Our Local Reviews by City
- Austin, TX (78)
- Buda, TX (331)
- Canyon Lake, TX (5)
- Creedmoor, TX (4)
- Dale, TX (1)
- Driftwood, TX (29)
- Dripping Springs, TX (26)
- Hays, TX (1)
- Kingsbury, TX (1)
- Kyle, TX (480)
- Lockhart, TX (15)
- Manchaca, TX (9)
- Martindale, TX (14)
- Maxwell, TX (3)
- Mountain City, TX (26)
- New Braunfels, TX (13)
- Niederwald, TX (15)
- San Marcos, TX (157)
- Seguin, TX (3)
- Uhland, TX (2)
- West Lake Hills, TX (1)
- Wimberley, TX (104)
- Woodcreek, TX (4)
Job Locations and Reviews
Installed 1.5 ton Carrier R-454B ductless system. Indoor unit mounted to the wall in the garage. Outdoor unit is mounted to the brick wall outside with mounting bracket. Made new flares connections for the refrigerant lines and pressure tested them with nitrogen. Checked for leaks with bubbles and pulled vacuum. Installed line hide to cover the lineset and condensation drain line. Installed new 20 amp breaker and ran new wiring to supply power to the system. Tested operation of system. Everything is working at completion of install.
Performed a/c tune-up on a Carrier straight cool system. Checked the electrical, mechanical and performance systems of the unit. Cleared, cleaned, flushed and treated the drain line and replaced the return air filter. Secured outdoor compressor wiring and washed the outdoor coil. Did find the indoor coil is starting to develop some rust spots and can be prone to a refrigerant leak in the future. No other issues were found. The system is operational at this time.
Performed a semi-annual maintenance inspection on both HVAC systems. Inspected all high- and low-voltage electrical wiring and connections and tightened the low-voltage connections as needed. Flushed and cleared both condensate drain lines and verified proper drainage. Inspected both blower assemblies and found no signs of buildup or biological growth. Evaporator coils were inspected and found to be clean and free of buildup. Washed both outdoor condensing units from the inside out and inspected all electrical components. Both soft-start systems were tested and confirmed to be operating properly. Run capacitors were tested and found to be within manufacturer specifications. Checked the refrigerant pressures on both systems and found them to be within the appropriate operating range. Both systems were tested and confirmed to be operating properly and cooling as expected at the completion of the maintenance.
Sealed all of the supply buckets and return boxes to the Sheetrock with mastic. Sealed the ductwork connections at the plenums with mastic. Cleaned the exterior of the furnace and evaporator coil. Cleared out the primary condensation drain and primed with water. System is operating and everything is working at completion of service.
Installed Carrier 4 ton furnace and condenser. Installed new plywood overlay. Installed new filter base. Installed a new supply plenum. Sealed all connections. Rebuilt drain and installed SS2. Cleared drain and primed trap. Replaced gas flex. Replaced flu pipe in closet. Installed new condenser pad and new disconnect. Pressure tested lineset and pulled a vacuum. Installed Ecobee thermostat. Tested system operation and charged system to meet manufacturer specifications. Everything is working at completion of install.
Performed AC cooling check. Checked the electrical, mechanical, safety, and performance of the system. I cleared the condensation drain line and flow tested the drain with water. I also treated the drain line. The air filters were new and had been recently replaced by the homeowner. I cleaned the condenser coil. No major issues were found. The system was running at the completion of service.
Service diagnostic found the blower motor had failed. This caused the indoor coil to freeze over. The secondary drain pan is slightly undersized and was not catching all the water from when the frozen coil thawed out. Also found the outdoor capacitor is starting to fail but is still operational. Spoke with the homeowner and he chose to have the blower motor replaced. I replaced the blower motor. Secured all furnace wiring terminals. Function tested the system and turned off the fresh air system to help decrease humidity levels in the home. Did find the system airflow was not matched to the outdoor system tonnage. This was causing the system to run with very high static pressure which most likely caused the motor to fail. I lowered the fan fan speed to deliver around 1100CFM for the 3-ton system. Informed the homeowner the system static pressure is still high at .85 in.w.c. Due to the location of the system there is no room for ductwork improvements. Also secured the compressor
Pumped down existing refrigerant to the condenser. Installed new TXV metering device and liquid line filter drier in the attic at the evaporator coil. Insulated the new sensing bulb. Pressure tested system with nitrogen and pulled vacuum. Cleared primary condensation drain and primed trap with water. Checked the factory condenser capacitor reading 42/45 and 4.6/5 it is still within spec. Charged AC with R-410A refrigerant. Tested operation of system. Everything is working at completion of service.
Diagnostics found the outdoor torque booster had failed, preventing the outdoor unit from coming on. I went over my findings and repair options with the homeowner and they chose to have the torque booster replaced today. After replacing the outdoor torque booster, I function tested the system. The system is cooling at time of departure.
Performed a/c tune-up on two heat pump systems. Checked the electrical, mechanical and performance systems of the units. Cleared, cleaned, flushed and treated the drain lines. Replaced both air filters and washed the outdoor coils. Did ask the homeowner to keep an eye on the upstairs system since the indoor coil is rusted out and prone to a refrigerant leak in the future. No other issues were found. Both systems are operational at this time.
Diagnostics found the condenser fan motor for the downstairs unit had seized up. I went over my findings and repair options with the homeowners. They chose to replace the condenser fan motor today. I replaced the condenser fan motor then cycled the system on to verify proper operation. The system was cooling at completion of service.
Service diagnostic found the outdoor fan motor had leaked out all the lubricant which was causing the motor to seize up and fail. Every time the fan motor shut down it caused the compressor to overheat and shut off as well. I spoke with the homeowner and he chose to have the outdoor fan motor replaced. I replaced the outdoor fan motor, programmed the motor to the correct speed, and rinsed out the outdoor coil. Did inform the homeowner the dryer vent is next to the condenser coil which is causing the coil to accumulate more dirt than usual. I also cleared out the primary drain at no additional charge to the customer. No other issues were found. The system is operational at this time.
Service diagnostic found the drain line was clogged which was tripping the water safety switch and causing the system to shut off. I also found the outdoor capacitor below manufacturer rated value. The outdoor starter relay is also pitted. Spoke to the homeowner and he chose to have the outdoor capacitor replaced. I replaced the capacitor and secured the outdoor wiring terminals. Cleared and treated the primary drain line and rinsed out the outdoor system at no additional charge to the homeowner. Did also recommend replacing the air filter with the correct size to prevent any filter bypass. Function tested the system and everything is now operational.
Service diagnostic found that the condensation drain line was clogged. Water had backed up into the safety switch and shut down the system. Options for repair were presented to the homeowners and they chose to have the drain line cleared and to sign up for maintenance. I cleared the condensation drain line and flow tested the drain with two gallons of water. Clear water was observed flowing freely out of the drain line. I function tested the system and the system was cooling with a 25 degree temperature split. The system is under a high heat load but was running at the completion of service.
Performed AC cooling check. Checked the electrical, mechanical, safety, and performance of the system. I cleared the condensation drain line and flow tested the drain with water. I also treated the drain line. The air filter was new and had been recently replaced by the homeowner. The condenser coil was cleaned. The capacitor on the condenser unit was reading 25 mfd on a 45 mfd capacitor. Options for repair were presented to the homeowner and he chose to have the capacitor replaced. I replaced the capacitor and function tested the system. The system was running at the completion of service.
Very knowledgeable found a problem that could have caused an outage at some point and we went ahead and corrected it at that time
Garner heating and air, is an excellent company to work with. The technicians especially Chey, are skilled, thorough, and very knowledgeable about every aspect of the HVAC systems.
Reliable service
Helped me solve a problem I had been grappling with for some time -changing my air filters. Worked with me to make sure I understood the process of installing new air filters on my own. Grateful for his insight and problem solving by also installing new air vent covers. All good!
I enjoyed working with their service tech, Eli, on resolving a somewhat tricky problem.
Ethan and his partner were professional and friendly. They installed and explained the new system to me and made sure I was satisfied.
Ethan was here from 6 am until around 5:30 pm. He worked all day in the heat and when the job was done STILL had a great attitude. He was friendly and knowledgeable!
Showed up promptly, were very kind and explained everything. Great service and overall completely satisfied!
Great and fast service..
Can’t speak highly enough about this team! Everytime and from start to finish they have shown that are top tier. They’ve never pushed more than what I needed, oversold, or done anything other than just been straight forward. Wouldn’t use another company other than Garner!