Garner AC primarily services Austin, TX and cities south of Austin. We also cover surrounding areas north of San Antonio, such as New Braunfels, TX. Whether you live near Driftwood, Dripping Springs, Manchaca, Uhland, Wimberly, Maxwell, Lockhart, Kyle, Woodcreek, Mountain City or San Marcos, we have you covered. If you are unsure if we provide heating and cooling service in your area, call us today.
The average cost to replace an HVAC system in Hays County is around $7,000-$15,000. The price can vary depending on:
- The type of HVAC unit you want installed.
- The size of the HVAC unit you will need.
- The cost to remove your old HVAC unit and install the new one.
Getting your old HVAC system replaced with a newer HVAC system is a great way to cut down on repair costs and energy costs each year. To find out more about getting your HVAC system replaced, contact us today.
A home HVAC system should be serviced at least twice a year in Hays County. Having your HVAC system serviced once before the cooling season and once before the heating season is the best way to ensure your HVAC system is able to run as efficiently as possible. Regular servicing can also help your HVAC system last longer and require less repairs. To get your HVAC system serviced, give us a call today.
If you'd like to know what your neighbors in Lockhart, TX think, just check out their reviews below!
Recent Jobs and Reviews in Lockhart, TX
Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting high levels of customer satisfaction and appreciation. Customers consistently express gratitude for the professionalism, punctuality, and expertise demonstrated by the service team. There is a strong recurring theme of technicians being knowledgeable, thorough, and excellent communicators who take time to explain issues, answer questions, and provide helpful advice without applying undue pressure. Many reviewers highlight the courteous and respectful nature of the staff, noting details such as wearing shoe covers, protecting work areas, and leaving spaces clean after completion. Timeliness emerges as another dominant positive trend, with numerous mentions of technicians arriving on time or even early, completing work efficiently, and providing same-day service. Customers frequently express confidence in the quality of work performed, even under challenging conditions like extreme heat, and many indicate strong loyalty, stating they will use the service again and recommend it to family and friends. The emotional tone is enthusiastic and appreciative, with reviewers describing their experiences as "great," "excellent," "fantastic," and "outstanding." Overall, the reviews convey a sense of trust, reliability, and exceptional customer care that has clearly resonated with clients.
Lockhart, TX at a glance
Garner Heating & Air Conditioning Inc has completed 25 jobs in Lockhart, TX between March 2022 and September 2023.
The most recent job was on September 25, 2023.
Garner Heating & Air Conditioning Inc has completed 17 jobs in Lockhart, TX in the last 12 months. The first job there was in July 2018.
Our Local Reviews by City
- Austin, TX (78)
- Buda, TX (331)
- Canyon Lake, TX (5)
- Creedmoor, TX (4)
- Dale, TX (1)
- Driftwood, TX (29)
- Dripping Springs, TX (26)
- Hays, TX (1)
- Kingsbury, TX (1)
- Kyle, TX (480)
- Lockhart, TX (15)
- Manchaca, TX (9)
- Martindale, TX (14)
- Maxwell, TX (3)
- Mountain City, TX (26)
- New Braunfels, TX (13)
- Niederwald, TX (15)
- San Marcos, TX (157)
- Seguin, TX (3)
- Uhland, TX (2)
- West Lake Hills, TX (1)
- Wimberley, TX (104)
- Woodcreek, TX (4)
Job Locations and Reviews
On arrival, I found the emergency water safety switch tripped due to a restriction inside the primary drain line. Removed power from system, blew out the primary drain line and flushed drain line out. Verified drain had proper flow of water and then treated the primary drain line with a drain treatment. Opened up the indoor air handler and cleaned out the primary drain pan and treated with a drain treatment inside the drain pan. Reset the cooling system and inspected all Performance, Mechanical and Safety Systems. Verified everything was operating within manufacture’s specifications for operation. Everything is working at this time.
Performed diagnostic. I found that the primary drain line was clogged and tripping the float switch. I cleared and treated the drain and tested it with a gallon of water. I ran the system for 30 minutes and no other major issues were found.
Installed new Carrier condenser and new TXV. Installed a new liquid line filter dryer, pressure tested system with dry nitrogen and pulled a vacuum on the copper line set. Replaced extended supply and return plenums and sealed with mastic air lock. Added 3 new return air filter grilles in the bedrooms. Replaced disconnect and whip at outdoor system. Charged system to factory specifications. System is working properly at time of departure.
Air Conditioning System Repair. Performed service diagnostic. Diagnostic found that the system was performing poorly. Sub cooling was very low, and the temperature split from return to supply was 8-10 degrees. Design sub cooling was checked through the service application on the thermostat control and the system determined a designed sub cooling of 18 degrees. Two pounds of R-410A was added to bring the sub cooling up to 18 degrees. Temperature split had improved to 14-15 degrees before I left. Return temperature was 70 degrees, supply temp was 55 degrees and outside air was 97 degrees. I asked the customer to monitor that system and let us know if it continues to have cooling issues. System was running at the time of departure
Performed the AC tune-up. Cleared and treated the drain line. Condenser coil clean. I did find that the capacitor on the indoor unit was below value. No other major issues found. Homeowner decided to have the capacitor replaced today. Repair complete and system is operational.
Installed customer supplied control board for outdoor mini split unit. Reset the cooling system and verified operation. Everything is working at this time.
Performed inspection. I found that the outdoor capacitor has failed. I also let the customer know that the condenser fan motor is showing signs of overheating. I presented the customer with options to repair and he chose to have the capacitor and the fan motor replaced at this time. I replaced both parts and cycled the thermostat. System is operational at this time.
Removed the old copper line set. Ran new copper from condenser to indoor coil. Set the new condenser and attached the copper. Ran new whip and new disconnect. Installed inline filter dryer, pressure tested with dry nitrogen, and pulled a vacuum on copper line set. Charged the system to factory specs with new refrigerant. System is operating properly at this time. Sealed all the ducts to the sheetrock with mastic and performed a duct cleaning on all the ducts.
Performed AC cool check. Checked electrical, mechanical, safety, and performance of the system. No major issues were found. Drain line cleared and treated. Condenser coil cleaned. Electrical disconnect confirmed in and on. System was running at the time of departure.
Installed new 4-ton Carrier gas system. Installed new Ecobee Lite. Rebuilt and insulated condensate drain line. Cleared and treated drain. Replaced secondary drain pan. Installed SS2 & SS3 float switches. Installed new filter dryer, pressure tested with dry nitrogen and pulled a vacuum on the copper line set. Replaced both supply and return plenums and sealed with mastic airlock. Installed new high-density filtration. Replaced disconnect at the condenser. Charged system to factory spec. System is working properly at time of departure.
Performed semiannual maintenance on one cooling system. Inspected all Performance, Mechanical and Safety Systems. Verified everything was operating within the manufacture’s specifications for operation. Outdoor condenser refrigerant pressures are within range and condenser cleaned. Indoor system drain line cleared and filter had already been recently changed. No major issues were found and system running at time of departure.
Performed semiannual maintenance on one cooling system. Inspected all Performance, Mechanical and Safety Systems. Verified everything was operating within the manufacture’s specifications for operation. Outside condenser refrigerant pressures are within range and condenser cleaned. Indoor system drain line cleared. Filter changed. No major issues were found. System running at time of departure.
Performed semiannual maintenance on one heat pump heating system. Inspected all Performance, Mechanical and Safety Systems. Verified everything was operating within the manufacture’s specifications for operation.
Performed heat check. Checked electrical, mechanical, safety, and performance of the system. No major issues were found. Drain line cleared and treated. Condenser coil clean. System sterilizer on and operational. Surge protection for the air handler and condenser were also operational. Thermostat was returned to the customer’s programed schedule. System was running at the time of departure. Please see attached checklist for full tune-up details.
Performed AC cool check. Checked electrical, mechanical, safety, and performance of the system. No major issues were found. Drain line cleared and treated. Condenser coil cleaned. System sterilizers were operational. Electrical disconnect confirmed in and on. System was running at the time of departure.
After performing the diagnostic, I found that the primary drain line was backed up. As a courtesy to the customer, I performed the AC tune-up and cleared the drain. Everything is working at this time. I did find deficiencies with the system, but the client declined further repairs.
Replaced the condenser fan motors for the 2 condensers that control the Ballroom. Replaced the starter on the condenser for the right side of the Ballroom. Installed safety float switches on the 2 systems in the Ballroom and on the system in the middle of the building. Installed a new secondary drain pan under the coil in the attic that controls the far-left side of the building. Everything is coming on and working at this time.
Performed AC maintenance check on a 2021 Carrier Infinity 5 Stage heat pump system. No major issues were found during maintenance.
Performed service diagnostic. Diagnostic found that the system was functioning. Gas pressure was checked, and flame sensor was cleaned. No error codes were present. All three lights were on, indicating normal function, and positive flame detection. Filter was changed. Electrical disconnect confirmed in and on. System was running at the time of departure.