Take advantage of our Free Duct Work Inspection

Google Rating
4.9
Based on 514 reviews

Niederwald TX Heating & Air Conditioning Services

Expert HVAC Service in Niederwald TX

Since 1988, residents of Niederwald, TX have trusted Garner Heating & Air Conditioning to provide professional work and outstanding service for all of their HVAC needs. If you're looking for a provider you can count on, call today!

Do air conditioning units need to be serviced near Niederwald, TX?

Yes, air conditioning units should be serviced in Niederwald, TX. Getting your air conditioning unit on a maintenance plan is a good way to ensure that your air conditioning system is cleaned, inspected and serviced on a regular basis. A well maintained unit typically lasts its full life expectancy and has fewer repair needs, whereas a poorly maintained unit requires many repairs, breaks down more frequently and has a shorter lifespan. To get your air conditioning unit serviced, contact us today.

Why is my home air conditioner not turning on near Niederwald, TX?

Your home air conditioner may not be turning on in Niederwald, TX because:

  • Your evaporator coil is frozen or broken.
  • The circuit to your air conditioner has tripped.
  • Your thermostat’s batteries are dead.

These are the most common reasons your air conditioner may not be working, but there are multiple reasons your air conditioner may not be turning on. If you are experiencing the last two issues, you may be able to fix it yourself. However, if your air conditioner is not turning on due to a different issue, you should get it repaired by an HVAC technician. Call us today to have your air conditioner repaired.

How often should my home air conditioner be maintained in Niederwald, TX?

Your home air conditioner should be maintained at least once a year in Niederwald, TX. The best time to get your air conditioner maintenanced is in the Spring, right before summer when you will be needing your air conditioner the most. This provides ample time to clean, inspect and diagnose your air conditioner before it is turned on. To learn more about getting your home air conditioner maintained, call Garner Heating & Air Conditioning today.

If you'd like to know what your neighbors in Niederwald, TX think, just check out their reviews below!

Recent Jobs and Reviews in Niederwald, TX

Rated 5.0 out of 5 stars based on 5 customer reviews

Customers say: The reviews exhibit a positive sentiment overall, with many customers expressing satisfaction with the services provided. The technicians are often described as friendly, knowledgeable, and professional, with some customers highlighting their punctuality and thoroughness. There are also mentions of excellent customer service, with technicians taking the time to explain the work done and answer any questions. Additionally, customers appreciate the cleanliness and quietness maintained during the service, as well as the respect shown for their property. The recurring themes include professionalism, expertise, courtesy, and efficiency. Overall, the reviews suggest that customers have had positive experiences with Garner Heating and Air Conditioning and would recommend their services.

Job Locations and Reviews

Chey S.
Chey S. Checked in
Heating maintenance completed on 4-year old electric heat system. No major issues found at this time.
Niederwald, TX 78640
Ethan D.
Ethan D. Checked in
Air Duct Cleaning and Sealing: A client reported excessive dust in their home and weak airflow in some rooms. We found that debris and mold growth inside the ducts were restricting airflow. After thoroughly cleaning and sealing the ducts, we improved both air quality and airflow. The homeowner was advised to schedule annual duct maintenance to avoid similar issues.
Niederwald, TX 78640
Omar H.
Omar H. Checked in
Performed the heater tune-up on a Carrier gas system. Checked the electrical, mechanical and performance systems of the unit. Cleared, cleaned, flushed and treated the drain line and cleaned the exterior of the furnace. I replaced the high voltage wire nuts with a Wago wire connector. I also replaced the return air filter. I checked the static pressure of the system and found that the fan speed was set to deliver roughly 1800 cfm on a 5-ton system. This air flow is good for this size system, but the total static pressure reading is .83 which is high. No other major issues were found, and the system is operational at this time.
Niederwald, TX 78640
Chey S.
Chey S. Checked in
Heating tune-up completed on a two-year-old horizontal furnace. I found that the static pressure on the system is slightly elevated. To resolve this issue, I lowered the fan speed to adjust for the 2.5-ton system. No other major issues were found.
Niederwald, TX 78640
Angel T.
Angel T. Checked in
Installed a new bucket in son’s bedroom and sealed it to the drywall. Replaced grille in son’s bathroom. Installed a reducer to go from a new 6” flex duct run to the existing 4” duct. Ran new 8” flex for son’s bedroom. Sealed all connections and installed dampers. Everything is operational at this time.
Niederwald, TX 78640
Review
Matt was an excellent technician, friendly yet professional. He was very thorough and did an excellent job! Would be glad to have him service our unit again.
Henry - Niederwald, TX 78640
Matt F.
Matt F. Checked in
Performed heater tune-up. Checked electrical, mechanical, safety, and performance of the system. I cleared the drain line and flow tested the drain with two gallons of water. I also treated the drain line. The filter for the furnace was replaced. No major issues were found, and the system is running at the completion of service.
Niederwald, TX 78640
Review
Angel Tinoco and his assistant did an excellent job of making modifications to the duct work in our home. They were knowledgeable and efficient. I would recommend them to anyone requiring repair of duct work
Martha - Niederwald, TX 78640
Response from Garner Heating & Air Conditioning Inc:

It was a pleasure serving you and your family. Thank you for sharing your kind words with us. It means the world to us and to our entire team!

Angel T.
Angel T. Checked in
Completed duct sealing. Sealed all buckets and returns to the drywall from the attic, with the exception of the laundry room, which was already sealed from the inside. Removed satellite plenum and installed sheet metal wyes to increase airflow. Ran new 8” flex duct. Removed wye going to bedrooms and made them into home runs to the supply plenum. Upsized bucket and sealed to the drywall. Verified drain operation.
Niederwald, TX 78640
Angel T.
Angel T. Checked in
Air Conditioning System Repairs: While troubleshooting a client’s AC unit, I found a clogged drain line causing water to back up into the system, threatening internal components. I cleared the clog and installed a float switch to prevent future overflows, ensuring the system would function smoothly throughout the autumn season.
Niederwald, TX 78640
Matt F.
Matt F. Checked in
Service diagnostic found that the condensate drain line was clogged. Water had backed up into the secondary drain line and tripped the safety switch. Options for repair were presented to the customer, and Mary chose to have the drain line cleared today. I cleared the drain line and tested the drain with two gallons of water. Clear water was observed flowing from the drain line outside the home. I then treated the drain. I function tested the system and the system is now operational.
Niederwald, TX 78640
Chey S.
Chey S. Checked in
Heating tune-up completed on a horizontal gas system. I did find that the inducer motor is slightly over amping and brought this to the attention of the homeowner. He is aware and will help us monitor. No other major issues found, and the system is heating properly at this time.
Niederwald, TX 78640
Omar H.
Omar H. Checked in
Performed diagnostic on the system and found that the blower motor has failed. I confirmed the motor is receiving a constant 24volts and 120volts from the furnace board. I presented my findings to the homeowner, and he chose to have the motor replaced and also have a surge protector installed on the furnace. I installed the motor and the surge protector at the furnace. I then cycled power at the thermostat. The total furnace static reading is .56 and the airflow is set to 1085 CFM on the 3-ton system. After checking the airflow, I wiped down the furnace as best as I could.
Niederwald, TX 78640
Chey S.
Chey S. Checked in
On arrival, the customer stated that the unit stopped working overnight. I began by checking the air filter, and then replaced it with a customer supplied filter. I then examined the evaporator coil and checked the float switch. I found that the float switch has tripped. Went outside to examine the condenser and found a faulty capacitor. Presented the customer with options for repair, and they chose to move forward with the items on the critical repair estimate. After replacing the capacitor, I vacuumed out, flushed and cleared the condensation drain line with CO2. Poured multiple gallons of water and was able to verify proper drainage before treating the drain line with Viper treatment. Cycled the system on cool mode to verify proper operation of unit. The system is cooling at this time.
Niederwald, TX 78640
Omar H.
Omar H. Checked in
Performed cooling maintenance on one heat pump system. Checked all electrical mechanical and performance of the system. Cleared and treated the drain line and washed the outdoor coil. I found the system does not have a water safety switch and there is some microbial growth at the air handler. I cleaned the microbial growth as best as I could. At the condenser I secured the compressor wiring to prevent any rub outs. The condenser fan motor is also showing signs of overheating. No other major issues found.
Niederwald, TX 78640
Angel T.
Angel T. Checked in
Duct Air Purifier Installation: Installed duct air purifiers to reduce pollutants and improve indoor air quality with advanced purification technology.
Niederwald, TX 78640
Chey S.
Chey S. Checked in
Single system cooling maintenance completed on a horizontal gas system. Indoor unit, fan and evaporator coil are clean. The drain line flushed and treated. The float switch was tested and is operational. Also replaced 4" media filter. The outdoor coils are clean, all electrical within manufacture specs and the refrigerant charge is within range. No major issues found.
Niederwald, TX 78640
Chey S.
Chey S. Checked in
Cool check completed on an up-flow air handler and condenser. The drain line has been cleared and treated. The float switch was checked and is working properly. The evaporator coil has significant buildup and I highly recommended it be cleaned in place. The condenser coils have been cleaned. All electrical is within manufactures specs. No other major issues found, and the system is cooling to the best of its ability at time of departure.
Niederwald, TX 78640
Matt F.
Matt F. Checked in
Performed AC cool check. Checked electrical, mechanical, safety, and performance of the system. The drain line was cleared and treated. The filter was replaced with a customer supplied filter. The blower wheel is clean. The wiring is tight and in good condition. The secondary drain line is piped in a way that would allow water to back flow into the secondary pan. The condenser fan motor and contactor are both in good condition. The condenser capacitor is within value. The refrigerant charge is within spec, and the condenser coil was cleaned. Options to upgrade the drain line and install a second safety switch were presented to the customer, and homeowner chose to have the safety switch installed. I added a safety switch to the secondary drain line so that water will trip the switch before it flows into the secondary pan. The system was function checked and is running at the time of departure.
Niederwald, TX 78640
Angel T.
Angel T. Checked in
AC Refrigerant Leak Repair: Fixed a refrigerant leak and recharged the AC system to restore its cooling capacity and efficiency.
Niederwald, TX 78640
Angel T.
Angel T. Checked in
AC Expansion Valve Adjustment: Adjusted a faulty expansion valve to optimize the AC system's cooling performance.
Niederwald, TX 78640
Chey S.
Chey S. Checked in
Cool check completed on a horizontal gas system. Cleared and treated the drain line. Checked the float switch and it is operational. The blower wheel is clean. Condenser coils are clean, and the refrigerant levels are within range. I did find that the capacitor is starting to fail. Presented my findings to the homeowner and they decided to have the capacitor replaced today. Completed repair and cycled the thermostat. The system is operational upon departure.
Niederwald, TX 78640
Chey S.
Chey S. Checked in
Upon arrival, the customer stated that the outdoor unit was making a humming sound. I verified the blower motor was running. Proceeded outside to inspect the heat pump and discovered that the capacitor has failed. Presented the customer with options to replace the capacitor, and they have decided to move forward with the repair. Replaced the capacitor, and verified the unit was cooling.
Niederwald, TX 78640
Chey S.
Chey S. Checked in
Cool check completed on a horizontal gas system. Replaced 4" media filter. The drain line was cleared and treated. Condenser coils clean. No major issues were found, and the system is operating properly at this time.
Niederwald, TX 78640
Matt F.
Matt F. Checked in
Performed AC cool check. Checked electrical, mechanical, safety, and performance of the system. The air handler and blower wheel are clean. The drain line was cleared and treated. The wiring is tight and in good condition. The condenser fan motor and contactor are in good condition. The capacitor for the condenser is within value. The refrigerant charge is within factory specifications. The condenser coil was cleaned. No major issues were found, and the system is running at the time of departure.
Niederwald, TX 78640
Omar H.
Omar H. Checked in
On arrival the customer stated that the outdoor unit would not turn on. I performed a diagnostic on the system and found that the outdoor capacitor had failed. I informed the homeowner, and he chose to have the capacitor replaced at this time. After I replaced the capacitor, I cycled power at the thermostat and the system is now operational.
Niederwald, TX 78640
Ethan D.
Ethan D. Checked in
Installed ductless system. Mounted wall bracket and installed line hide. The electricians ran high voltage and installed a disconnect. Pressure tested and pulled a vacuum on the copper line set. Verified system operation.
Niederwald, TX 78640
Review
Matt was awesome to work with!!
Adam - Niederwald, TX 78640
Review
As I shared in Google everything went fine and smooth and communication was great.
Adrian - Niederwald, TX 78640
Response from Garner Heating & Air Conditioning Inc:

It was a pleasure serving you and your family. We really appreciate you taking the time to share your feedback with us and the community.

Review
It's been quite a while since I've observed such a customer-centered strong work ethic! And that includes every single person I interacted with every single time--from the phone conversations, the in home estimate, the technical work to the final "customer satisfaction" follow up visit. (By the way, who does that!) Speaking of the follow up visit...I am especially grateful to Ryan! We discussed that I needed more storage space in the attic, and he took time to explain what I needed to do using 2x4s and my plywood pieces. He had to go to the shop to get a stapler gun to better secure part of (?something :0). When he returned he had 2x4s, a circular saw and nail gun. He said if I was okay with it he would create my additional attic storage space. WHAT!!!! He had the pieces cut and installed within about 30 minutes! I was already so happy with everything and everyone, but this put a huge "WOW!!" in my head! So, because of Ryan, I have to add "kindness" and "generosity" to my description of this company and its employees!
Cheryl - Niederwald, TX 78640
Kyle . Buda . San Marcos . Wimberley . Driftwood . Martindale . Manchaca . Lockhart . New Braunfels
Schedule Now Text Us Now
Award Winning Service
  • Google Guaranteed
  • Carrier Authorized Dealer Logo
  • Service Round Table Member Logo
  • Best Or North Hays Logo
  • Nate Certified Technicians Logo
  • National Comfort Institute Inc Logo