Expert HVAC Service in Niederwald TX
Since 1988, residents of Niederwald, TX have trusted Garner Heating & Air Conditioning to provide professional work and outstanding service for all of their HVAC needs. If you're looking for a provider you can count on, call today!
Yes, air conditioning units should be serviced in Niederwald, TX. Getting your air conditioning unit on a maintenance plan is a good way to ensure that your air conditioning system is cleaned, inspected and serviced on a regular basis. A well maintained unit typically lasts its full life expectancy and has fewer repair needs, whereas a poorly maintained unit requires many repairs, breaks down more frequently and has a shorter lifespan. To get your air conditioning unit serviced, contact us today.
Your home air conditioner may not be turning on in Niederwald, TX because:
- Your evaporator coil is frozen or broken.
- The circuit to your air conditioner has tripped.
- Your thermostat’s batteries are dead.
These are the most common reasons your air conditioner may not be working, but there are multiple reasons your air conditioner may not be turning on. If you are experiencing the last two issues, you may be able to fix it yourself. However, if your air conditioner is not turning on due to a different issue, you should get it repaired by an HVAC technician. Call us today to have your air conditioner repaired.
Your home air conditioner should be maintained at least once a year in Niederwald, TX. The best time to get your air conditioner maintenanced is in the Spring, right before summer when you will be needing your air conditioner the most. This provides ample time to clean, inspect and diagnose your air conditioner before it is turned on. To learn more about getting your home air conditioner maintained, call Garner Heating & Air Conditioning today.
If you'd like to know what your neighbors in Niederwald, TX think, just check out their reviews below!
Recent Jobs and Reviews in Niederwald, TX
Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting high levels of customer satisfaction and appreciation. Customers consistently express gratitude for the professionalism, punctuality, and expertise demonstrated by the service team. There is a strong recurring theme of technicians being knowledgeable, thorough, and excellent communicators who take time to explain issues, answer questions, and provide helpful advice without applying undue pressure. Many reviewers highlight the courteous and respectful nature of the staff, noting details such as wearing shoe covers, protecting work areas, and leaving spaces clean after completion. Timeliness emerges as another dominant positive trend, with numerous mentions of technicians arriving on time or even early, completing work efficiently, and providing same-day service. Customers frequently express confidence in the quality of work performed, even under challenging conditions like extreme heat, and many indicate strong loyalty, stating they will use the service again and recommend it to family and friends. The emotional tone is enthusiastic and appreciative, with reviewers describing their experiences as "great," "excellent," "fantastic," and "outstanding." Overall, the reviews convey a sense of trust, reliability, and exceptional customer care that has clearly resonated with clients.
Niederwald, TX at a glance
Garner Heating & Air Conditioning Inc has completed 25 jobs in Niederwald, TX between July 2025 and April 2026.
The most recent job was on April 24, 2026.
Garner Heating & Air Conditioning Inc has completed 37 jobs in Niederwald, TX in the last 12 months. The first job there was in October 2018.
Our Local Reviews by City
- Austin, TX (78)
- Buda, TX (331)
- Canyon Lake, TX (5)
- Creedmoor, TX (4)
- Dale, TX (1)
- Driftwood, TX (29)
- Dripping Springs, TX (26)
- Hays, TX (1)
- Kingsbury, TX (1)
- Kyle, TX (480)
- Lockhart, TX (15)
- Manchaca, TX (9)
- Martindale, TX (14)
- Maxwell, TX (3)
- Mountain City, TX (26)
- New Braunfels, TX (13)
- Niederwald, TX (15)
- San Marcos, TX (157)
- Seguin, TX (3)
- Uhland, TX (2)
- West Lake Hills, TX (1)
- Wimberley, TX (104)
- Woodcreek, TX (4)
Job Locations and Reviews
Service diagnostic found that the circuit breaker for the condenser unit had failed. The circuit breaker was only passing power on one leg of the circuit. Options for repair were presented to the homeowner. She chose to have the failed breaker replaced. I replaced the circuit breaker and function tested the system. The system was operating normally and was running at the completion of service
Cool check completed for a horizontal straight cool system. Outdoor coils were cleaned. Drain line was flushed and treated. All mechanical and electrical components were checked. I did find LRA amps to the compressor above factory set limits. No other major issues were found. The system is running at completion of service.
Performed heater tune-up on a Carrier furnace system. Checked the electrical, mechanical and performance systems of the unit. Cleared, cleaned, flushed and treated the drain line and cleaned the exterior of the furnace. I did adjust the airflow to deliver 1190 cfm for the 3 ton system. This dropped the static pressure from .95 to .7 which is still high for the system. No other issues were found. The system is operational at this time.
Performed heater tune-up on a Carrier propane furnace system. Checked the electrical, mechanical and performance systems of the unit. Cleared, cleaned, flushed and treated the drain line. Replaced the 16x25x4 Honeywell filter for the homeowner. No major issues were found. The system is operational at this time.
Performed heater tune-up on a 2021 gas furnace. No major issues were found during the tune-up. The system is running at completion of service.
Performed heater tune-up on a Carrier heat pump system. Checked the electrical, mechanical and performance systems of the unit. Cleared, cleaned, flushed and treated the drain line and cleaned the exterior of the air handler. Verified the outdoor compressor wiring is secure and washed the outdoor coil. I did find the blower wheel has some biological growth. No other issues were found. The system is operational at this time.
Performed heat check. Checked the electrical, mechanical, safety, and performance of the system. I cleared the condensation drain line and flow tested the drain with two gallons of water. The air filter was clean and had been recently replaced by the homeowner. The surge protectors and system sterilizers are operational. No major issues were found. The system was running at the completion of service.
Heat check completed on a vertical heat pump system. Drain line was cleaned and flushed. Condensing coils were cleaned. All mechanical and electrical components were checked and found within manufacturer specifications. No major issues were found. The system is heating properly at this time.
Heat check completed for one horizontal gas system. Drain line was flushed and treated. Flame sensor was cleaned. All mechanical and electrical components were checked. I did find the static pressure of the system is higher than factory specifications. No other issues were found. The furnace is heating properly at time of departure.
Performed heater tune-up on a Carrier gas furnace system. Checked the electrical, mechanical and performance systems of the unit. Cleared, cleaned, flushed and treated the drain line and cleaned the exterior of the furnace. I replaced the high voltage wire nuts with a Wago wire connector. As I was finishing the tune-up on the furnace I did notice the roof has a small water leak by the dryer vent penetration. No major issues were found. The system is operational at this time.
Performed heat check. Checked the electrical, mechanical, safety, and performance of the system. I cleared the condensation drain line and flow tested the drain with two gallons of water. I also treated the drain line. The air filter was replaced with a client supplied filter. No major issues were found. The system was running at the completion of service.
Heat check completed on a horizontal gas system. Flame sensor was cleaned. Drain line was flushed and treated. I adjusted the gas pressure. No major issues were found. The system is heating properly at time of departure.
On arrival, I found that the system was not running with the thermostat on a call for cool. I went through the system and found that the run capacitor at the outdoor unit had failed across the HERM terminals. I went up into the attic and also found that the primary drain line was backed up and tripped the water safety switch. I installed a new outdoor run capacitor and new power surge protector at the outdoor unit. Installed all new wiring terminal connections and secured high voltage lugs. I cleaned and cleared the primary drain line and added in drain treatment solution to help ensure the system drains condensate properly from the evaporator coil to the downstairs bathroom sink. Cycled high voltage power to the system and checked over operation. Everything is working at this time.
Performed AC cool check. Checked the electrical, mechanical, safety, and performance of the system. I cleared the condensation drain line and flow tested the drain with two gallons of water. I also treated the drain line. The air filters had been recently replaced by the homeowner. At the condenser unit, I did find that the capacitor was below value. Options for repair were presented to the homeowner and Shaun chose to have the capacitor replaced and to sign up for our gold maintenance. I replaced the capacitor and function tested the system. The system is operational and was running at the completion of service. See attached tune-up checklist for additional details.
Installed new Lennox evaporator coil. Installed new liquid line filter drier in attic. Added extra foam block support on supply plenum. Sealed ductwork connections with mastic and hardcast. Pressure tested system with nitrogen and pulled vacuum. Cleared primary drain with CO2 and primed trap with water. Charged AC with R-410A refrigerant. Tested operation of system. Everything is working at completion of service.
Recovered refrigerant in the system. Replaced filter drier and replaced outdoor condensing coil. Pressure tested system and pulled a vacuum. Installed Surge Protector. Upon startup, realized compressor had shorted to ground. Recovered all refrigerant and replaced compressor. Pressure tested lineset and weighed in all new refrigerant and additional charge to meet manufacturer specifications. Everything is operational at this time.
AC cool check completed on one horizontal Trane unit. Drain line was flushed and treated. Condenser coils were cleaned. All mechanical and electrical components are within manufacturer specs. No major issues were found. The system was running at completion of service.
Performed AC cool check. Checked the electrical, mechanical, safety, and performance of the system. I cleared the condensation drain line and flow tested the drain with two gallons of water. I also treated the drain line. The air filters were clean and had been recently replaced by the tenant. I cleaned the condenser coil. The capacitor on the condenser unit was below value. Options for repair were presented to the homeowner. He chose to have the capacitor replaced today. I replaced the condenser capacitor and function tested the system. The system is operational and was running at the completion of service.
Spoke with the homeowner when I arrived. On system startup the outdoor condenser would make a loud rattling noise but he figured it had something to do with the movers the day prior having the house open the complete day. We went outside to take a look at the unit and I pulled the disconnect. The condenser fan motor began to shake turning off. I installed the disconnect back in and did verify the rattling noise. Will need to install a new condenser fan motor at the outdoor condensing unit to return the unit back to designed operation. I went over repair options with the homeowner and he chose to have the condenser fan motor replaced. I installed a new condenser fan motor, programmed the motor for rotation and speed rating, and cycled on high voltage power. Checked over operations and verified everything was operating within manufacturer specifications for operation. Everything was working at completion of service.
After diagnosing system, I found the critical issue being the torque booster. I visited with the homeowner over the phone about options for repair. He has decided to become our newest maintenance member and have the torque booster replaced today. I replaced the torque booster and cycled both thermostats to verify proper operation. The system is cooling at time of departure.
Performed an A/C tune-up on a Carrier straight cool system. Checked the electrical, mechanical and performance systems of the unit. Cleared, cleaned, flushed and treated the drain line and cleaned the exterior of the furnace. The return air filter is dirty. Secured outdoor compressor wiring and washed the outdoor coil. All UV lights and surge protection devices are working. System is operational at this time.
Air Conditioning Installation: Installed a new Lennox high-SEER AC system, including a variable-speed air handler and smart thermostat. Verified duct compatibility, balanced airflow throughout the home, and registered the unit for warranty on behalf of the homeowner.
Pumped down existing refrigerant to the condenser. Installed new Carrier evaporator coil with new TXV. Installed new liquid line filter drier. Pressure tested system with nitrogen and pulled vacuum. Built duct board transition between furnace and new coil. Rebuilt primary condensation drain. Cleared primary drain with CO2 and primed trap with water. Sealed connections with mastic and hardcast. Charged the system with R-410A refrigerant. Tested heating and cooling operation of system. Everything is working at completion of service.
Performed semiannual maintenance on one cooling system. Inspected all performance, mechanical and safety systems. Tested and verified everything was operating within manufacturer specifications for operation. Did find the static pressure to be high. Everything is working at this time.
Performed AC cool check. Checked the electrical, mechanical, safety, and performance of the system. I cleared the condensation drain line and flow tested the drain with two gallons of water. I also treated the drain line. The air filter was replaced with a client supplied filter. Condenser coil was cleaned. No major issues were found. The system was running at the completion of service.