Sign up today for our Gold Plan, now only $299/yr! (was $339)

Kyle TX Heating & Air Conditioning Services

Get the Best HVAC Service

Garner Heating & Air Conditioning offers over 35 years experience in servicing, repairing, and replacing your HVAC system, so let us take that pressure off of you. We'll do the work - you enjoy the comfort. Call 512-392-2000 for all your HVAC replacement, repair and maintenance service near Kyle, TX or contact us online with any questions.

Garner heating and air truck driving in kyle texas

HVAC Replacement Service in Kyle, TX

Like all major appliances in your home, your HVAC system is made up of countless parts all working in concert to provide your home welcoming comfort. Those parts need to be properly maintained and cared for so you always have the warming heat or refreshing cool you need. But who has the time to do that themselves?

If your AC unit is more than 10-15 years old, replacing it could save you money on energy bills and repair costs. Upgrading to a new, energy-efficient system can improve comfort, reduce maintenance, and lower your electricity usage.

When Should You Replace Your HVAC System?

  • Your AC needs frequent, costly repairs.
  • Your unit is over 10 years old and struggles to cool your home.
  • Energy bills have steadily increased despite regular maintenance.
  • Your home has uneven temperatures from room to room.

What Size AC Unit Do You Need?

The right AC size depends on your home’s square footage, insulation, and layout. An oversized unit may cool too quickly without removing humidity, while an undersized unit will struggle to keep up. Our HVAC experts perform a full evaluation to recommend the best system for your home.

Expert Air Conditioning Repair in Kyle, TX

If your AC isn’t keeping up with the heat, it might be time for repairs. Common signs your air conditioner needs servicing include:

  • Warm air blowing from vents – This could indicate low refrigerant levels or a failing compressor.
  • Unusual noises – Grinding, squealing, or rattling sounds could mean parts are loose or worn out.
  • High energy bills – If your energy costs are rising, your system may be struggling to run efficiently.
  • Frequent cycling – If your AC turns on and off repeatedly, it could be a sign of thermostat issues or restricted airflow.

How Long Does AC Repair Take?

Most AC repairs can be completed within a few hours, depending on the problem. Our team arrives with the tools and parts needed to diagnose and fix issues quickly. If a major repair is needed, we’ll discuss your options and provide transparent pricing before starting any work.

Heating and Cooling Service FAQs

What should I do if my air conditioner freezes?

If your air conditioner freezes, follow these steps to get your unit functioning again:

  • Turn off the unit from the breaker. This will allow the unit to thaw. FYI, thawing could take an entire day.
  • Do not remove the ice by hand to avoid damaging the unit.
  • After thawing, dry the coils by turning back on your unit but on the fan setting only. This helps circulate air and dry the coils quickly. 
  • Turn the AC back on to see if it operates without freezing over.
What is the average AC repair cost near Kyle TX?

Homeowners can anticipate paying between $100 - $500 for air conditioner repairs. 

Why is my air conditioner leaking water?

A faulty drain pan, loose connections, or worn-out components can lead to costly water damage. Catching minor issues early prevents major headaches down the road.

How much does a new HVAC system cost in Kyle TX?

The cost to replace a heating and cooling system typically ranges from $5,000 to $15,000, depending on factors like the size of the home, system efficiency, and installation requirements.

If it's Garner, It's Guaranteed

We know it can be difficult to bring someone into your home and trust them to do the work right. That's why Garner offers at 100% satisfaction guarantee on all the service we perform. We want you to be certain, before we even step through the door, that you're going to get the right solutions, at the right price, with the right quality.

Give us a call at 512-392-2000 and make us your partner in comfort today. Of course, the best opinion on our work comes from your neighbors. See what they have to say about Garner Heating & Air Conditioning below.

Recent Jobs and Reviews in Kyle, TX

Rated 5.0 out of 5 stars based on 480 customer reviews

Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting high levels of customer satisfaction and appreciation. Customers consistently express gratitude for the professionalism, punctuality, and expertise demonstrated by the service team. There is a strong recurring theme of technicians being knowledgeable, thorough, and excellent communicators who take time to explain issues, answer questions, and provide helpful advice without applying undue pressure. Many reviewers highlight the courteous and respectful nature of the staff, noting details such as wearing shoe covers, protecting work areas, and leaving spaces clean after completion. Timeliness emerges as another dominant positive trend, with numerous mentions of technicians arriving on time or even early, completing work efficiently, and providing same-day service. Customers frequently express confidence in the quality of work performed, even under challenging conditions like extreme heat, and many indicate strong loyalty, stating they will use the service again and recommend it to family and friends. The emotional tone is enthusiastic and appreciative, with reviewers describing their experiences as "great," "excellent," "fantastic," and "outstanding." Overall, the reviews convey a sense of trust, reliability, and exceptional customer care that has clearly resonated with clients.

Kyle, TX at a glance

Garner Heating & Air Conditioning Inc has completed 15 jobs in Kyle, TX between February 2024 and March 2024.

The most recent job was on March 8, 2024.

Garner Heating & Air Conditioning Inc has completed 525 jobs in Kyle, TX in the last 12 months. The first job there was in July 2018.

Job Locations and Reviews

Matt F.
Matt F. Checked in
Service diagnostic found that the power wire from the defrost control board to the condenser fan motor was broken. The fan motor had been replaced some time before they had moved into the home and whoever had done the work zip tied the wire tight against a metal edge. I ran the new wire from the defrost control board to the fan motor. The system was function checked and is operational. System was running at the time of departure.
Kyle, TX 78640
Matt F.
Matt F. Checked in
Performed AC cool check. Checked electrical, mechanical, safety, and performance of the system. Drain line was cleared and treated. Air handler and blower wheel are clean. Electrical connections are tight and in good condition. Condenser fan motor is in good condition. Capacitor is within value. Disconnect is also in good condition and the surge protection is operational. Condenser coil was cleaned. System was set to the customer’s desired setting and was running at the time of departure. See attached checklist for full tune up details.
Kyle, TX 78640
Ethan D.
Ethan D. Checked in
Replaced supply plenum and sealed all duct and plenum connections with mastic air lock. Cleared and treated primary drain line. Installed surge protector for outdoor condenser. Everything is operational at this time.
Kyle, TX 78640
Matt F.
Matt F. Checked in
This system is a 3-ton Carrier heat pump. I checked electrical, mechanical, safety and performance of the system. The filter was dirty and they didn’t have a replacement filter on hand. The return and supply ducts are clean. Evaporator coil, blower wheel and air handler are also clean. Electrical wiring is tight. Auxiliary heat strips are operational and running at 19 amps. I cleared the condensation drain line and flow tested the drain with water. I then treated the drain. Condenser coil was clean. Refrigerant pressure within range. Condenser fan motor disconnect and contactor are in good condition. Capacitor for the condenser unit is within value. Electrical connections are tight. I spared JS ant treatment around the contactor and electrical connections to prevent damage from ants. System was running at the time of departure. See attached checklist for full tune-up details.
Kyle, TX 78640
Elijah D.
Elijah D. Checked in
On arrival, I met with the homeowner who stated that his thermostat went blank the other day. His neighbor came and replaced the fuse in the indoor furnace, but it still would not work. I went through the system and found that the outdoor starter relay was shorted, which was causing the control voltage fuse to blow. Installed new relay and new indoor control fuse. Verified all wiring was secure and all connections were done correctly. While on-site, performed semiannual maintenance on one straight electric cooling system. Inspected all Performance, Mechanical and Safety Systems. Verified everything was working within manufacture’s specifications for operation. Everything is working at this time. See attached checklist for full tune-up details.
Kyle, TX 78640
Brendan B.
Brendan B. Checked in
Indoor Air Purification System Installation: Addressing a homeowner's concern about indoor air quality, we facilitated the seamless installation of a cutting-edge indoor air purifier. Expert positioning and meticulous integration maximized air purification capabilities, contributing to a healthier and more refreshing indoor environment. The new air purifier effectively addresses identified areas for improvement in the homeowner's living space.
Kyle, TX 78640
Omar H.
Omar H. Checked in
On arrival, the customer stated that he noticed that his outdoor condenser fan motor had not been working since last night. After I inspected the system, I found that the motor had failed. I presented repair options to the customer, and he chose to have it replaced with our Azure universal motor. I replaced the motor and cycled power at the thermostat confirming that the motor is now working. I then performed maintenance on the system and checked all electrical, mechanical and performance of the system. I also cleared the drain line and washed the outdoor coil. No other major issues were found, and the system is operational at this time. See attached checklist for full tune-up details.
Kyle, TX 78640
Omar H.
Omar H. Checked in
Performed heating maintenance on one furnace system. Checked all electrical, mechanical and performance of the system. I found that the blower motor capacitor is below value. I informed the customer and presented options for repair. She chose to have it replaced at this time. I replaced the capacitor and cycled power at the thermostat. No other major issues found. See attached checklist for full tune-up details.
Kyle, TX 78640
Matt F.
Matt F. Checked in
Performed service diagnostic. Diagnostic found that the condensate drain line was clogged. Water had backed up and tripped the safety switch. Blower motor capacitor is also below value. Options for repair were presented to the customer and they chose to have the drain cleared and have the capacitor today. He also chose to sign up for our maintenance plan. I cleared the drain line and flow tested the drain with water. I also treated the drain line. I replaced the capacitor and tested the system. Everything is working properly at this time.
Kyle, TX 78640
Elijah D.
Elijah D. Checked in
On arrival, I started the cooling system and found that the exhaust fan motor was not running. Tested the charge rating of the run capacitor and found it to still be within range on both the FAN and HERM side of terminals. Looked closely at the motor wiring and found burn marks coming out of the motor area. Recommended replacement of the condenser fan motor and the homeowner agreed. Installed new motor and programmed it to match system specifications. Once fully installed, I tested the system and verified everything was operating within manufacture’s specifications for operation.
Kyle, TX 78640
Matt F.
Matt F. Checked in
Performed heater check on a Goodman gas furnace. Checked electrical, mechanical, safety, and performance of the system. Drain line was cleared and treated. Return duct and blower wheel are dusty. Flame sensor was cleaned. Igniter is within value and operational. Blower motor capacitor is within value. Inducer motor is operational and drawing normal amperage. No other major issues were found. See attached checklist for full tune-up details. Options for cleaning were presented to the customer. They declined the repair but asked that we email an estimate. System was running at the time of departure.
Kyle, TX 78640
Zachary V.
Zachary V. Checked in
Homeowner mentioned that it had quit heating a couple of days ago. I went over the system and discovered the following: the system is a 90% Goodman furnace on natural gas. The air filter underneath the system was completely clogged up. The safety limits had been cutting the furnace off due to a lack of airflow. I removed the filter and replaced it with a new one from the customer. I then was able to cycle the heat and everything fired up and ran without any issues. I also went over the rest of the heating system. I found that the capacitor for the inducer motor has a broken spade connector. I went ahead and got that connection fixed after checking the capacitor. I also switched the heating system down to a 10-minute stage up delay. I found the temperature rise to be within spec. I also adjusted gas pressures to get them closer to the manufacturer’s specifications. System is in working order at completion of appointment.
Kyle, TX 78640
Zachary V.
Zachary V. Checked in
Homeowner mentioned that it had quit heating a couple of days ago. I went over the system and discovered the following: the system is a 90% Goodman furnace on natural gas. The air filter underneath the system was completely clogged up. The safety limits had been cutting the furnace off due to a lack of airflow. I removed the filter and replaced it with a new one from the customer. I then was able to cycle the heat and everything fired up and ran without any issues. I also went over the rest of the heating system. I found that the capacitor for the inducer motor has a broken spade connector. I went ahead and got that connection fixed after checking the capacitor. I also switched the heating system down to a 10-minute stage up delay. I found the temperature rise to be within spec. I also adjusted gas pressures to get them closer to the manufacturer’s specifications. System is in working order at completion of appointment.
Kyle, TX 78640
Zachary V.
Zachary V. Checked in
Homeowner mentioned that it had quit heating a couple of days ago. I went over the system and discovered the following: the system is a 90% Goodman furnace on natural gas. The air filter underneath the system was completely clogged up. The safety limits had been cutting the furnace off due to a lack of airflow. I removed the filter and replaced it with a new one from the customer. I then was able to cycle the heat and everything fired up and ran without any issues. I also went over the rest of the heating system. I found that the capacitor for the inducer motor has a broken spade connector. I went ahead and got that connection fixed after checking the capacitor. I also switched the heating system down to a 10-minute stage up delay. I found the temperature rise to be within spec. I also adjusted gas pressures to get them closer to the manufacturer’s specifications. System is in working order at completion of appointment.
Kyle, TX 78640
Zachary V.
Zachary V. Checked in
Homeowner mentioned that it had quit heating a couple of days ago. I went over the system and discovered the following: the system is a 90% Goodman furnace on natural gas. The air filter underneath the system was completely clogged up. The safety limits had been cutting the furnace off due to a lack of airflow. I removed the filter and replaced it with a new one from the customer. I then was able to cycle the heat and everything fired up and ran without any issues. I also went over the rest of the heating system. I found that the capacitor for the inducer motor has a broken spade connector. I went ahead and got that connection fixed after checking the capacitor. I also switched the heating system down to a 10-minute stage up delay. I found the temperature rise to be within spec. I also adjusted gas pressures to get them closer to the manufacturer’s specifications. System is in working order at completion of appointment.
Kyle, TX 78640
Kyle . Buda . San Marcos . Wimberley . Driftwood . Martindale . Manchaca . Lockhart . New Braunfels
Schedule Now Text Us Now
Award Winning Service
  • Google Guaranteed
  • Carrier Authorized Dealer Logo
  • Service Round Table Member Logo
  • Best Or North Hays Logo
  • Nate Certified Technicians Logo
  • National Comfort Institute Inc Logo