Sign up today for our Gold Plan, now only $299/yr! (was $339)

Kyle TX Heating & Air Conditioning Services

Get the Best HVAC Service

Garner Heating & Air Conditioning offers over 35 years experience in servicing, repairing, and replacing your HVAC system, so let us take that pressure off of you. We'll do the work - you enjoy the comfort. Call 512-392-2000 for all your HVAC replacement, repair and maintenance service near Kyle, TX or contact us online with any questions.

Garner heating and air truck driving in kyle texas

HVAC Replacement Service in Kyle, TX

Like all major appliances in your home, your HVAC system is made up of countless parts all working in concert to provide your home welcoming comfort. Those parts need to be properly maintained and cared for so you always have the warming heat or refreshing cool you need. But who has the time to do that themselves?

If your AC unit is more than 10-15 years old, replacing it could save you money on energy bills and repair costs. Upgrading to a new, energy-efficient system can improve comfort, reduce maintenance, and lower your electricity usage.

When Should You Replace Your HVAC System?

  • Your AC needs frequent, costly repairs.
  • Your unit is over 10 years old and struggles to cool your home.
  • Energy bills have steadily increased despite regular maintenance.
  • Your home has uneven temperatures from room to room.

What Size AC Unit Do You Need?

The right AC size depends on your home’s square footage, insulation, and layout. An oversized unit may cool too quickly without removing humidity, while an undersized unit will struggle to keep up. Our HVAC experts perform a full evaluation to recommend the best system for your home.

Expert Air Conditioning Repair in Kyle, TX

If your AC isn’t keeping up with the heat, it might be time for repairs. Common signs your air conditioner needs servicing include:

  • Warm air blowing from vents – This could indicate low refrigerant levels or a failing compressor.
  • Unusual noises – Grinding, squealing, or rattling sounds could mean parts are loose or worn out.
  • High energy bills – If your energy costs are rising, your system may be struggling to run efficiently.
  • Frequent cycling – If your AC turns on and off repeatedly, it could be a sign of thermostat issues or restricted airflow.

How Long Does AC Repair Take?

Most AC repairs can be completed within a few hours, depending on the problem. Our team arrives with the tools and parts needed to diagnose and fix issues quickly. If a major repair is needed, we’ll discuss your options and provide transparent pricing before starting any work.

Heating and Cooling Service FAQs

What should I do if my air conditioner freezes?

If your air conditioner freezes, follow these steps to get your unit functioning again:

  • Turn off the unit from the breaker. This will allow the unit to thaw. FYI, thawing could take an entire day.
  • Do not remove the ice by hand to avoid damaging the unit.
  • After thawing, dry the coils by turning back on your unit but on the fan setting only. This helps circulate air and dry the coils quickly. 
  • Turn the AC back on to see if it operates without freezing over.
What is the average AC repair cost near Kyle TX?

Homeowners can anticipate paying between $100 - $500 for air conditioner repairs. 

Why is my air conditioner leaking water?

A faulty drain pan, loose connections, or worn-out components can lead to costly water damage. Catching minor issues early prevents major headaches down the road.

How much does a new HVAC system cost in Kyle TX?

The cost to replace a heating and cooling system typically ranges from $5,000 to $15,000, depending on factors like the size of the home, system efficiency, and installation requirements.

If it's Garner, It's Guaranteed

We know it can be difficult to bring someone into your home and trust them to do the work right. That's why Garner offers at 100% satisfaction guarantee on all the service we perform. We want you to be certain, before we even step through the door, that you're going to get the right solutions, at the right price, with the right quality.

Give us a call at 512-392-2000 and make us your partner in comfort today. Of course, the best opinion on our work comes from your neighbors. See what they have to say about Garner Heating & Air Conditioning below.

Recent Jobs and Reviews in Kyle, TX

Rated 5.0 out of 5 stars based on 480 customer reviews

Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting high levels of customer satisfaction and appreciation. Customers consistently express gratitude for the professionalism, punctuality, and expertise demonstrated by the service team. There is a strong recurring theme of technicians being knowledgeable, thorough, and excellent communicators who take time to explain issues, answer questions, and provide helpful advice without applying undue pressure. Many reviewers highlight the courteous and respectful nature of the staff, noting details such as wearing shoe covers, protecting work areas, and leaving spaces clean after completion. Timeliness emerges as another dominant positive trend, with numerous mentions of technicians arriving on time or even early, completing work efficiently, and providing same-day service. Customers frequently express confidence in the quality of work performed, even under challenging conditions like extreme heat, and many indicate strong loyalty, stating they will use the service again and recommend it to family and friends. The emotional tone is enthusiastic and appreciative, with reviewers describing their experiences as "great," "excellent," "fantastic," and "outstanding." Overall, the reviews convey a sense of trust, reliability, and exceptional customer care that has clearly resonated with clients.

Kyle, TX at a glance

Garner Heating & Air Conditioning Inc has completed 15 jobs in Kyle, TX between May 2023 and June 2023.

The most recent job was on June 2, 2023.

Garner Heating & Air Conditioning Inc has completed 525 jobs in Kyle, TX in the last 12 months. The first job there was in July 2018.

Job Locations and Reviews

Matt F.
Matt F. Checked in
Performed service diagnostic. Diagnostic found that the system was operational but was low on refrigerant. Leak check was performed, and no leak was detected. The evaporator coil also appears to be new. I asked the homeowner about the new coil but they did not know if it had been replaced due to only being in the home three months. Options for repair were presented to customer and they chose to have the system charged with refrigerant. Repair was completed and system was running at the time of departure.
Kyle, TX 78640
Elijah D.
Elijah D. Checked in
On arrival, I started the cooling system on both thermostats. Accessed the outdoor system and found only the fan motor running; the compressor was not running. Inspected all electrical and found that the run capacitor has failed below value. Installed a new outdoor run capacitor and reset the system. Inspected all Performance, Mechanical and Safety Systems. I did note the outdoor exhaust motor has overheated and informed the homeowner of my concerns. Everything is working at this time. System had a 17° temperature split upon departure.
Kyle, TX 78640
Isaiah M.
Isaiah M. Checked in
Performed the AC tune-up. I did find that the capacitor had fallen below value. No other major issues found. Presented repair options and the customer chose to have the capacitor replaced today. Completed repair and system is operational.
Kyle, TX 78640
Ethan D.
Ethan D. Checked in
On arrival, the homeowner showed me photos of the coil she took. Coil and suction line was frozen. I accessed the outdoor unit and checked refrigerant levels. Found system to be extremely low on refrigerant, which caused the system to freeze over. I further inspected the indoor coil and found refrigerant vapor coming out of the indoor coil. I used soap bubble leak detection and pinpointed location of leak to the micro channel coil tubing. Showed the homeowner the leak and we agreed issue needs to be fixed asap. Installed new evaporator coil and TXV on indoor unit. Removed refrigerant in system and installed a new line filter dryer. Pressure tested system for extensive leak check and pulled deep vacuum. Weighed in factory charge per data tag and verified operation. Everything working at this time.
Kyle, TX 78640
Jason D.
Jason D. Checked in
Installed new 3-ton Carrier gas system. Installed new Honeywell T6 thermostat. Rebuilt and insulated condensate drain line. Added SS2 safety float switch. Cleared and treated drain and verified operation. Installed new filter dryer, pressure tested with dry nitrogen and pulled a vacuum on the copper line set. Built a transition to existing supply plenum and sealed with mastic airlock. Replaced disconnect and whip at outdoor system. Charged system to factory spec. System is working properly at time of departure.
Kyle, TX 78640
Elijah D.
Elijah D. Checked in
During my diagnosis I found that the zone control board was failing to pass power from the upstairs thermostat through to the equipment, which caused the low-temp cutoff to be activated turning off the equipment. Tested thermostat on zone 1 and tested both dampers for operation. All other equipment is running per design. Recommend installing new zone board to return system back to operation. Installed new zone board, tested all systems and zones and verified operation. Verified zone panel was correctly programmed for system operation. Everything is working at this time.
Kyle, TX 78640
Ethan D.
Ethan D. Checked in
Installed new Carrier heat pump system. Added new plywood overlay and rebuilt drain line with an SS-2 safety switch. Sealed field transition with air lock and mastic tape. Installed new filter dryer and pressure tested system for extensive leak check. Pulled vacuum and weighed in factory charge. Replaced outdoor disconnect and installed Ecobee Pro thermostat. System operating properly at this time.
Kyle, TX 78640
Matt F.
Matt F. Checked in
Performed service diagnostic. Diagnostic found that the capacitor on the condenser unit has failed. Condenser fan motor is also showing signs of overheating. Lastly, the condenser coil is in need of cleaning. Options for repair were presented to the customer and they chose to have the capacitor replaced only. Capacitor was replaced. The system was function checked and was running at the time of departure.
Kyle, TX 78640
Matt F.
Matt F. Checked in
Performed service diagnostic. Diagnostic found that the duct temperature sensor for the zone control board has failed. The sensor is shutting down on low temperature limit due to incorrect temperature reading. Condenser capacitor is also below value. Options for repair were presented to the customer and they chose to have the duct temperature sensor replaced only at this time. Duct temperature sensor was replaced. The system was function checked and was running at the time of departure.
Kyle, TX 78640
Matt F.
Matt F. Checked in
Performed service diagnostic. Diagnostic found that the condenser coil is dirty. Condenser fan motor is showing signs of overheating. Options for repair were presented to the customer and they chose to have the condenser coil cleaned today. Condenser coil was cleaned. Electrical disconnect confirmed in and on. System was running at the time of departure.
Kyle, TX 78640
Matt F.
Matt F. Checked in
Performed service diagnostic. Diagnostic found that the primary condensate drain line was clogged. Options for repair were presented to the customer and they chose to have the drain cleared today and to sign up for our bi-annual maintenance plan. Drain line was cleared and flow tested with water. Drain line was treated. System was function checked and was running at the time of departure.
Kyle, TX 78640
Matt F.
Matt F. Checked in
Performed service diagnostic. Diagnostic found that the primary condensate drain was clogged. Options for repair were presented to the customer and they chose to have the drain line cleared today and signed up for bi-annual maintenance. Drain line was cleared and treated. System was function checked and was running at the time of departure.
Kyle, TX 78640
Marissa I.
Marissa I. Checked in
Performed service diagnostic. Diagnostic found that the system had frozen over. Blower fan in the air handler was operational. Condenser unit was running constantly because the contactor in the condenser unit was stuck closed. Condenser capacitor was below value and depleting. Condenser fan motor showed signs of overheating. Options for repair were presented to the customer and they chose to have the contactor, condenser fan motor and capacitor replaced today. They also opted in for our maintenance plan. Repairs were completed. System had thawed by the time the repairs were completed. System was function checked and was running at the time of departure.
Kyle, TX 78640
Jason D.
Jason D. Checked in
Installed new 4-ton Carrier system. Installed two T6 Honeywell thermostats. Rebuilt and insulated condensate drain line. Added SS2 safety float switch. Cleared and treated drain and verified operation. Installed new filter dryer, pressure tested with dry nitrogen and pulled a vacuum on copper line set. Built a transition to existing supply plenum and sealed with mastic airlock. Replaced disconnect and whip at outdoor system. Charged system to factory spec. System is working properly at time of departure.
Kyle, TX 78640
Isaiah M.
Isaiah M. Checked in
Performed semiannual maintenance. Inspected all Performance, Mechanical and Safety Systems. Verified everything was working within manufacture’s specifications for operation. Everything is working at this time.
Kyle, TX 78640
Kyle . Buda . San Marcos . Wimberley . Driftwood . Martindale . Manchaca . Lockhart . New Braunfels
Schedule Now Text Us Now
Award Winning Service
  • Google Guaranteed
  • Carrier Authorized Dealer Logo
  • Service Round Table Member Logo
  • Best Or North Hays Logo
  • Nate Certified Technicians Logo
  • National Comfort Institute Inc Logo