Get the Best HVAC Service
Garner Heating & Air Conditioning offers over 35 years experience in servicing, repairing, and replacing your HVAC system, so let us take that pressure off of you. We'll do the work - you enjoy the comfort. Call 512-392-2000 for all your HVAC replacement, repair and maintenance service near Kyle, TX or contact us online with any questions.
HVAC Replacement Service in Kyle, TX
Like all major appliances in your home, your HVAC system is made up of countless parts all working in concert to provide your home welcoming comfort. Those parts need to be properly maintained and cared for so you always have the warming heat or refreshing cool you need. But who has the time to do that themselves?
If your AC unit is more than 10-15 years old, replacing it could save you money on energy bills and repair costs. Upgrading to a new, energy-efficient system can improve comfort, reduce maintenance, and lower your electricity usage.
When Should You Replace Your HVAC System?
- Your AC needs frequent, costly repairs.
- Your unit is over 10 years old and struggles to cool your home.
- Energy bills have steadily increased despite regular maintenance.
- Your home has uneven temperatures from room to room.
What Size AC Unit Do You Need?
The right AC size depends on your home’s square footage, insulation, and layout. An oversized unit may cool too quickly without removing humidity, while an undersized unit will struggle to keep up. Our HVAC experts perform a full evaluation to recommend the best system for your home.
Expert Air Conditioning Repair in Kyle, TX
If your AC isn’t keeping up with the heat, it might be time for repairs. Common signs your air conditioner needs servicing include:
- Warm air blowing from vents – This could indicate low refrigerant levels or a failing compressor.
- Unusual noises – Grinding, squealing, or rattling sounds could mean parts are loose or worn out.
- High energy bills – If your energy costs are rising, your system may be struggling to run efficiently.
- Frequent cycling – If your AC turns on and off repeatedly, it could be a sign of thermostat issues or restricted airflow.
How Long Does AC Repair Take?
Most AC repairs can be completed within a few hours, depending on the problem. Our team arrives with the tools and parts needed to diagnose and fix issues quickly. If a major repair is needed, we’ll discuss your options and provide transparent pricing before starting any work.
Heating and Cooling Service FAQs
If your air conditioner freezes, follow these steps to get your unit functioning again:
- Turn off the unit from the breaker. This will allow the unit to thaw. FYI, thawing could take an entire day.
- Do not remove the ice by hand to avoid damaging the unit.
- After thawing, dry the coils by turning back on your unit but on the fan setting only. This helps circulate air and dry the coils quickly.
- Turn the AC back on to see if it operates without freezing over.
Homeowners can anticipate paying between $100 - $500 for air conditioner repairs.
A faulty drain pan, loose connections, or worn-out components can lead to costly water damage. Catching minor issues early prevents major headaches down the road.
The cost to replace a heating and cooling system typically ranges from $5,000 to $15,000, depending on factors like the size of the home, system efficiency, and installation requirements.
If it's Garner, It's Guaranteed
We know it can be difficult to bring someone into your home and trust them to do the work right. That's why Garner offers at 100% satisfaction guarantee on all the service we perform. We want you to be certain, before we even step through the door, that you're going to get the right solutions, at the right price, with the right quality.
Give us a call at 512-392-2000 and make us your partner in comfort today. Of course, the best opinion on our work comes from your neighbors. See what they have to say about Garner Heating & Air Conditioning below.
Recent Jobs and Reviews in Kyle, TX
Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting high levels of customer satisfaction and appreciation. Customers consistently express gratitude for the professionalism, punctuality, and expertise demonstrated by the service team. There is a strong recurring theme of technicians being knowledgeable, thorough, and excellent communicators who take time to explain issues, answer questions, and provide helpful advice without applying undue pressure. Many reviewers highlight the courteous and respectful nature of the staff, noting details such as wearing shoe covers, protecting work areas, and leaving spaces clean after completion. Timeliness emerges as another dominant positive trend, with numerous mentions of technicians arriving on time or even early, completing work efficiently, and providing same-day service. Customers frequently express confidence in the quality of work performed, even under challenging conditions like extreme heat, and many indicate strong loyalty, stating they will use the service again and recommend it to family and friends. The emotional tone is enthusiastic and appreciative, with reviewers describing their experiences as "great," "excellent," "fantastic," and "outstanding." Overall, the reviews convey a sense of trust, reliability, and exceptional customer care that has clearly resonated with clients.
Kyle, TX at a glance
Garner Heating & Air Conditioning Inc has completed 15 jobs in Kyle, TX in June 2023.
The most recent job was on June 14, 2023.
Garner Heating & Air Conditioning Inc has completed 525 jobs in Kyle, TX in the last 12 months. The first job there was in July 2018.
Our Local Reviews by City
- Austin, TX (78)
- Buda, TX (331)
- Canyon Lake, TX (5)
- Creedmoor, TX (4)
- Dale, TX (1)
- Driftwood, TX (29)
- Dripping Springs, TX (26)
- Hays, TX (1)
- Kingsbury, TX (1)
- Kyle, TX (480)
- Lockhart, TX (15)
- Manchaca, TX (9)
- Martindale, TX (14)
- Maxwell, TX (3)
- Mountain City, TX (26)
- New Braunfels, TX (13)
- Niederwald, TX (15)
- San Marcos, TX (157)
- Seguin, TX (3)
- Uhland, TX (2)
- West Lake Hills, TX (1)
- Wimberley, TX (104)
- Woodcreek, TX (4)
Job Locations and Reviews
Performed cooling maintenance. Checked electrical, mechanical and performance of the system. Cleared and treated the drain line and washed the condenser coil. No major issues found. See attached checklist for full tune-up details.
Performed service diagnostic. Diagnostic found that the primary condensate drain line was clogged. Water had backed up and tripped the safety switch. Options for repair were presented to the customer and they chose to have the drain line cleared today. Drain line was cleared and flow tested with water. Drain line was treated. System was function checked and was running at the time of departure.
Performed service diagnostic. Diagnostic found that the primary condensate drain line was clogged. Water had backed up and tripped the safety switch. Options for repair were presented to the customer and they chose to have the drain line cleared. Drain line was cleared and treated. System was function checked and was running at the time of departure.
Performed cooling maintenance. Checked electrical, mechanical and performance of the system. Cleared and treated drain line and washed the condenser coil. Also replaced 4 inch media filter. I found the condenser fan motor showing signs of overheating. Please see attached checklist for full tune-up details. I presented the customer with options to repair, and he chose to have the motor replaced and add surge protection to the condenser and the air handler in the attic. After completing repairs, I cycled the thermostat everything is on and running at this time.
On arrival, I found the thermostat set to cool, but the outdoor heat pump was not pumping any refrigerant. I turned off the high voltage power to the system and checked the outdoor run capacitor. I found the capacitor to have failed well below value. I replaced the capacitor and started the system up. I then noticed that there was no power being passed through to the contactor. I diagnosed that the low-pressure switch had stuck open. I removed the top of the fan shroud and tapped on the pressure switch and it seated back closed. The outdoor system came on and ran as designed. The indoor filter has not been changed in some time and is extremely clogged up causing an airflow restriction. A replacement filter (AprilAire 210) needs to be purchased and installed. The homeowner had an F100 filter inside and I informed the homeowner that the correct filter needs to be installed to ensure proper airflow and air filtration. Everything is working at this time.
Performed cooling maintenance. Checked electrical, mechanical and performance of the system. Cleared and treated the drain line and washed the condenser coil. No major issues were found. I replaced the 4-inch media filter. UV lights are on and operational. System is working at this time.
Performed cooling maintenance. Checked electrical, mechanical and performance of the system. Cleared and treated drain line and washed the condenser coil. No major issues were found. System is on and running at this time.
Performed AC cool check. Checked electrical, mechanical, safety, and performance of the system. No major issues were found. Drain line cleared and treated. Condenser coil cleaned. Electrical disconnect confirmed in and on. System was running at the time of departure.
Performed AC cool check. Checked electrical, mechanical, safety, and performance of the system. No major issues were found. Drain line was cleared and treated. Condenser coil cleaned. Electrical disconnect confirmed in and on. System was running at the time of departure.
Performed cooling maintenance. Checked electrical, mechanical and performance of the system. Cleared and treated the drain line and washed the condenser coil. I did find that the transformer needs to be replaced. No other major issues were found. The system is on and running at this time
Performed cooling maintenance. Checked electrical, mechanical and performance of the system. Cleared and treated the drain line and washed the condenser coil. I did find that the transformer needs to be replaced. No other major issues were found. The system is on and running at this time
Found compressor plug terminals have melted. Installed new grounding plugs and started system. System currently operational.
On arrival, the homeowner stated that the air coming from vents was not cold. I performed diagnostics and found the refrigerant charge to be extremely low. Went into the attic to perform a refrigerant leak search, but was unable to do so do to the location of the HVAC system. I was unable to access the coil panel as it was up against the beams of the home, facing the opposite direction of the crawl area. Informed homeowner of this issue and he said he would just like to recharge the system for the time being. I added in 6.5# of R-410A refrigerant. Inspected temperature difference between the return and supply vents and informed homeowner to purchase replacement filters, as the current ones installed are extremely clogged up. System was running with a 12°SH and a 12°SC upon departure.
Performed cooling maintenance. Checked electrical, mechanical and performance of the system. Cleared and treated drain line and washed the condenser coil. I found that the 3 UV lights had tripped the transformer. I separated one of the lights and added it to a new transformer. All three lights are now working properly. No other major issues were found. System is on and running at this time.
Performed service diagnostic. Diagnostic found that the system was low on refrigerant. Leak check was performed and no leaks where detected. Options for repair were presented to the customer and they chose to have refrigerant added today. Refrigerant was balanced by adding 4 lbs. Upon departure, the system was operating at 9 degrees of sub cooling per data plate.