Sign up today for our Gold Plan, now only $299/yr! (was $339)

Kyle TX Heating & Air Conditioning Services

Get the Best HVAC Service

Garner Heating & Air Conditioning offers over 35 years experience in servicing, repairing, and replacing your HVAC system, so let us take that pressure off of you. We'll do the work - you enjoy the comfort. Call 512-392-2000 for all your HVAC replacement, repair and maintenance service near Kyle, TX or contact us online with any questions.

Garner heating and air truck driving in kyle texas

HVAC Replacement Service in Kyle, TX

Like all major appliances in your home, your HVAC system is made up of countless parts all working in concert to provide your home welcoming comfort. Those parts need to be properly maintained and cared for so you always have the warming heat or refreshing cool you need. But who has the time to do that themselves?

If your AC unit is more than 10-15 years old, replacing it could save you money on energy bills and repair costs. Upgrading to a new, energy-efficient system can improve comfort, reduce maintenance, and lower your electricity usage.

When Should You Replace Your HVAC System?

  • Your AC needs frequent, costly repairs.
  • Your unit is over 10 years old and struggles to cool your home.
  • Energy bills have steadily increased despite regular maintenance.
  • Your home has uneven temperatures from room to room.

What Size AC Unit Do You Need?

The right AC size depends on your home’s square footage, insulation, and layout. An oversized unit may cool too quickly without removing humidity, while an undersized unit will struggle to keep up. Our HVAC experts perform a full evaluation to recommend the best system for your home.

Expert Air Conditioning Repair in Kyle, TX

If your AC isn’t keeping up with the heat, it might be time for repairs. Common signs your air conditioner needs servicing include:

  • Warm air blowing from vents – This could indicate low refrigerant levels or a failing compressor.
  • Unusual noises – Grinding, squealing, or rattling sounds could mean parts are loose or worn out.
  • High energy bills – If your energy costs are rising, your system may be struggling to run efficiently.
  • Frequent cycling – If your AC turns on and off repeatedly, it could be a sign of thermostat issues or restricted airflow.

How Long Does AC Repair Take?

Most AC repairs can be completed within a few hours, depending on the problem. Our team arrives with the tools and parts needed to diagnose and fix issues quickly. If a major repair is needed, we’ll discuss your options and provide transparent pricing before starting any work.

Heating and Cooling Service FAQs

What should I do if my air conditioner freezes?

If your air conditioner freezes, follow these steps to get your unit functioning again:

  • Turn off the unit from the breaker. This will allow the unit to thaw. FYI, thawing could take an entire day.
  • Do not remove the ice by hand to avoid damaging the unit.
  • After thawing, dry the coils by turning back on your unit but on the fan setting only. This helps circulate air and dry the coils quickly. 
  • Turn the AC back on to see if it operates without freezing over.
What is the average AC repair cost near Kyle TX?

Homeowners can anticipate paying between $100 - $500 for air conditioner repairs. 

Why is my air conditioner leaking water?

A faulty drain pan, loose connections, or worn-out components can lead to costly water damage. Catching minor issues early prevents major headaches down the road.

How much does a new HVAC system cost in Kyle TX?

The cost to replace a heating and cooling system typically ranges from $5,000 to $15,000, depending on factors like the size of the home, system efficiency, and installation requirements.

If it's Garner, It's Guaranteed

We know it can be difficult to bring someone into your home and trust them to do the work right. That's why Garner offers at 100% satisfaction guarantee on all the service we perform. We want you to be certain, before we even step through the door, that you're going to get the right solutions, at the right price, with the right quality.

Give us a call at 512-392-2000 and make us your partner in comfort today. Of course, the best opinion on our work comes from your neighbors. See what they have to say about Garner Heating & Air Conditioning below.

Recent Jobs and Reviews in Kyle, TX

Rated 5.0 out of 5 stars based on 480 customer reviews

Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting high levels of customer satisfaction and appreciation. Customers consistently express gratitude for the professionalism, punctuality, and expertise demonstrated by the service team. There is a strong recurring theme of technicians being knowledgeable, thorough, and excellent communicators who take time to explain issues, answer questions, and provide helpful advice without applying undue pressure. Many reviewers highlight the courteous and respectful nature of the staff, noting details such as wearing shoe covers, protecting work areas, and leaving spaces clean after completion. Timeliness emerges as another dominant positive trend, with numerous mentions of technicians arriving on time or even early, completing work efficiently, and providing same-day service. Customers frequently express confidence in the quality of work performed, even under challenging conditions like extreme heat, and many indicate strong loyalty, stating they will use the service again and recommend it to family and friends. The emotional tone is enthusiastic and appreciative, with reviewers describing their experiences as "great," "excellent," "fantastic," and "outstanding." Overall, the reviews convey a sense of trust, reliability, and exceptional customer care that has clearly resonated with clients.

Kyle, TX at a glance

Garner Heating & Air Conditioning Inc has completed 15 jobs in Kyle, TX in July 2024.

The most recent job was on July 19, 2024.

Garner Heating & Air Conditioning Inc has completed 528 jobs in Kyle, TX in the last 12 months. The first job there was in July 2018.

Job Locations and Reviews

Ethan D.
Ethan D. Checked in
Installed Carrier gas system. Installed Ecobee thermostat. Built new supply plenum and return plenums and sealed all connections with mastic. Completed re-duct with new buckets and flex. Sealed all the buckets to the drywall. Replaced secondary drain pan. Rebuilt and insulated primary and secondary drain lines. Cleared, treated and verified drain operation. Installed SS2 and SS3 safety switches. Replaced disconnect and whip at outdoor unit. Ran low voltage in 1/2-inch Seal-Tite. Charged system to manufacture specifications.
Kyle, TX 78640
Zachary V.
Zachary V. Checked in
I arrived at the home to find the system off. I spoke to customer about how the unit had been performing. I checked over the system and discovered that the blower wheel had pulled apart and that has caused the motor to be off balance. Also, one of the legs of the motor broke from the extreme vibration. I brought all of this to the attention of the customer and made him an option to get it repaired. He elected to move forward with the repairs. I replaced the capacitor as well as the blower motor and blower wheel. I tested the system and found it to be working. The downstairs area is cooling now. System is in working order at completion of appointment.
Kyle, TX 78640
Zachary V.
Zachary V. Checked in
I arrived at the home to find the system off. I spoke to customer about how the unit had been performing. I checked over the system and discovered that the blower wheel had pulled apart and that has caused the motor to be off balance. Also, one of the legs of the motor broke from the extreme vibration. I brought all of this to the attention of the customer and made him an option to get it repaired. He elected to move forward with the repairs. I replaced the capacitor as well as the blower motor and blower wheel. I tested the system and found it to be working. The downstairs area is cooling now. System is in working order at completion of appointment.
Kyle, TX 78640
Zachary V.
Zachary V. Checked in
I arrived at the home to find the system off. I spoke to customer about how the unit had been performing. I checked over the system and discovered that the blower wheel had pulled apart and that has caused the motor to be off balance. Also, one of the legs of the motor broke from the extreme vibration. I brought all of this to the attention of the customer and made him an option to get it repaired. He elected to move forward with the repairs. I replaced the capacitor as well as the blower motor and blower wheel. I tested the system and found it to be working. The downstairs area is cooling now. System is in working order at completion of appointment.
Kyle, TX 78640
Zachary V.
Zachary V. Checked in
I arrived at the home to find the system off. I spoke to customer about how the unit had been performing. I checked over the system and discovered that the blower wheel had pulled apart and that has caused the motor to be off balance. Also, one of the legs of the motor broke from the extreme vibration. I brought all of this to the attention of the customer and made him an option to get it repaired. He elected to move forward with the repairs. I replaced the capacitor as well as the blower motor and blower wheel. I tested the system and found it to be working. The downstairs area is cooling now. System is in working order at completion of appointment.
Kyle, TX 78640
Omar H.
Omar H. Checked in
Performed cooling maintenance on one system. Checked all electrical, mechanical and performance of the system. Cleared and treated the drain line and washed the outdoor coil. I found that one of the connector’s terminals on the capacitor was starting to burn up. I stripped back new wire and replaced the connector. The hard start kit was not mounted correctly, so I remounted the kit to prevent any problems in the near future. I also found that the system is slightly low on R-22 refrigerant. The high voltage wire nuts are undersized at the furnace. I replaced the wire nuts at the furnaces and informed the homeowner of my findings. No other major issues found.
Kyle, TX 78640
Chey S.
Chey S. Checked in
Cool check completed on a horizontal heat pump system. The outside coils have been cleaned and all electrical within manufacture specs. Refrigerant charge does have low superheat, but temperature differential is 20°. The indoor coil and blower motor are both clean. One of the float switches has failed. I recommend a p-trap be added to the drain line for proper drainage. I also found that the supply plenum has partially detached and there is leakage around the ducts attached to the supply plenum. No other major issues found.
Kyle, TX 78640
Omar H.
Omar H. Checked in
On arrival the homeowner stated that his outdoor unit was not turning on so he turned the system off at the thermostat. I turned the system on at the thermostat and everything came on. I checked through the system and found that the primary drain line is clogged tripping the water safety switch which is shutting off the outdoor unit, and the return air filter is stuck on the underside of the coil. I removed the filter. I also found that the evaporator coil is dirty, there is mildew growth inside the air handler, there is no water safety switch on the secondary drain line, and the outdoor condenser fan motor is also leaking lubricant. I presented my findings to the homeowner, and he chose to have the drain line cleared at this time. I cleared and treated the drain and then tested it with two gallons of water. System is draining properly and operational at this time.
Kyle, TX 78640
Chey S.
Chey S. Checked in
Cool check completed on a horizontal heat pump system. The indoor coil and fan are both clean. The emergency drain pan underneath the air handler is showing significant signs of rust and I recommend replacing it. The drain line was cleared and both float switches are working. The condenser coil has been cleaned and all electrical within manufacture specs. The refrigerant charge is within range. Added new locking caps on the condenser. No other major issues found.
Kyle, TX 78640
Jason D.
Jason D. Checked in
Installed new evaporator coil. Rebuilt the condensation drain. Cleared, flushed and treated the drain to confirm proper drainage. Replaced the in-line filter dryer, pressure tested with dry nitrogen and pulled a vacuum on copper line set. Charged and tested the system. The system is working properly at this time.
Kyle, TX 78640
Angel T.
Angel T. Checked in
Installed Carrier gas system. Used homeowner’s thermostat. Built new supply plenum and sealed all connections with mastic. Installed plywood overlay. Rebuilt and insulated primary drain line. Cleared, treated and verified drain operation. Installed SS2 safety float switch. Replaced disconnect and whip at outdoor unit. Moved outside condenser over because pad was very un-level. Ran low voltage in 1/2-inch Seal-Tite. Verified charge was to manufacture specifications. System operational at this time.
Kyle, TX 78640
Omar H.
Omar H. Checked in
On arrival I found the system off at the thermostat. I spoke with the customer, and he stated that the system was only blowing hot air. I performed a diagnostic on the system and found that the outdoor capacitor has fallen below value on the herm side. It was reading 2.9 mfd and it is rated for 45 mfd. I informed the customer, and he chose to have the capacitor replaced at this time. I replaced the capacitor and cycled power at the thermostat. No other major issues were found, and the system is operational at this time.
Kyle, TX 78640
Chey S.
Chey S. Checked in
Cool check completed. The drain line was cleared and treated. The float switch was checked and is operational. No issues found with the components for operation of the system. I did find a supply duct run to the master bedroom has been split in two. Presented my findings to the homeowner and they approved the repair. Completed repair and cycled the system to ensure repair and proper air flow to the bedroom.
Kyle, TX 78640
Ethan D.
Ethan D. Checked in
Installed new 3-ton Carrier gas system. Installed new Honeywell T6 thermostat. Rebuilt and insulated condensate drain line. Added SS2 safety float switch. Cleared drain line with CO2 and ran three gallons of water to ensure proper operation. I then followed that with Viper drain treatment. Installed new filter dryer, pressure tested with dry nitrogen and pulled a vacuum on copper line set. Replace the condenser pad. Replaced the disconnect and ran the low voltage in Seal-Tite. Replaced supply plenums, sealed with a mastic airlock and reused zoning equipment. Charged system to factory spec and performed a benchmark. The system is working properly at time of departure.
Kyle, TX 78640
Angel T.
Angel T. Checked in
Installed Carrier system. Installed Ecobee thermostat. Transitioned to supply plenum and sealed all connections with mastic. Installed plywood overlay. Rebuilt and insulated primary drain line. Cleared, treated, and verified drain operation. Installed SS2 safety float switch. Replaced disconnect and whip at outdoor unit. Ran low voltage in 1/2-inch Seal-Tite. Charged system to manufacture specifications.
Kyle, TX 78640
Kyle . Buda . San Marcos . Wimberley . Driftwood . Martindale . Manchaca . Lockhart . New Braunfels
Schedule Now Text Us Now
Award Winning Service
  • Google Guaranteed
  • Carrier Authorized Dealer Logo
  • Service Round Table Member Logo
  • Best Or North Hays Logo
  • Nate Certified Technicians Logo
  • National Comfort Institute Inc Logo