Get the Best HVAC Service
Garner Heating & Air Conditioning offers over 35 years experience in servicing, repairing, and replacing your HVAC system, so let us take that pressure off of you. We'll do the work - you enjoy the comfort. Call 512-392-2000 for all your HVAC replacement, repair and maintenance service near Kyle, TX or contact us online with any questions.
HVAC Replacement Service in Kyle, TX
Like all major appliances in your home, your HVAC system is made up of countless parts all working in concert to provide your home welcoming comfort. Those parts need to be properly maintained and cared for so you always have the warming heat or refreshing cool you need. But who has the time to do that themselves?
If your AC unit is more than 10-15 years old, replacing it could save you money on energy bills and repair costs. Upgrading to a new, energy-efficient system can improve comfort, reduce maintenance, and lower your electricity usage.
When Should You Replace Your HVAC System?
- Your AC needs frequent, costly repairs.
- Your unit is over 10 years old and struggles to cool your home.
- Energy bills have steadily increased despite regular maintenance.
- Your home has uneven temperatures from room to room.
What Size AC Unit Do You Need?
The right AC size depends on your home’s square footage, insulation, and layout. An oversized unit may cool too quickly without removing humidity, while an undersized unit will struggle to keep up. Our HVAC experts perform a full evaluation to recommend the best system for your home.
Expert Air Conditioning Repair in Kyle, TX
If your AC isn’t keeping up with the heat, it might be time for repairs. Common signs your air conditioner needs servicing include:
- Warm air blowing from vents – This could indicate low refrigerant levels or a failing compressor.
- Unusual noises – Grinding, squealing, or rattling sounds could mean parts are loose or worn out.
- High energy bills – If your energy costs are rising, your system may be struggling to run efficiently.
- Frequent cycling – If your AC turns on and off repeatedly, it could be a sign of thermostat issues or restricted airflow.
How Long Does AC Repair Take?
Most AC repairs can be completed within a few hours, depending on the problem. Our team arrives with the tools and parts needed to diagnose and fix issues quickly. If a major repair is needed, we’ll discuss your options and provide transparent pricing before starting any work.
Heating and Cooling Service FAQs
If your air conditioner freezes, follow these steps to get your unit functioning again:
- Turn off the unit from the breaker. This will allow the unit to thaw. FYI, thawing could take an entire day.
- Do not remove the ice by hand to avoid damaging the unit.
- After thawing, dry the coils by turning back on your unit but on the fan setting only. This helps circulate air and dry the coils quickly.
- Turn the AC back on to see if it operates without freezing over.
Homeowners can anticipate paying between $100 - $500 for air conditioner repairs.
A faulty drain pan, loose connections, or worn-out components can lead to costly water damage. Catching minor issues early prevents major headaches down the road.
The cost to replace a heating and cooling system typically ranges from $5,000 to $15,000, depending on factors like the size of the home, system efficiency, and installation requirements.
If it's Garner, It's Guaranteed
We know it can be difficult to bring someone into your home and trust them to do the work right. That's why Garner offers at 100% satisfaction guarantee on all the service we perform. We want you to be certain, before we even step through the door, that you're going to get the right solutions, at the right price, with the right quality.
Give us a call at 512-392-2000 and make us your partner in comfort today. Of course, the best opinion on our work comes from your neighbors. See what they have to say about Garner Heating & Air Conditioning below.
Recent Jobs and Reviews in Kyle, TX
Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting high levels of customer satisfaction and appreciation. Customers consistently express gratitude for the professionalism, punctuality, and expertise demonstrated by the service team. There is a strong recurring theme of technicians being knowledgeable, thorough, and excellent communicators who take time to explain issues, answer questions, and provide helpful advice without applying undue pressure. Many reviewers highlight the courteous and respectful nature of the staff, noting details such as wearing shoe covers, protecting work areas, and leaving spaces clean after completion. Timeliness emerges as another dominant positive trend, with numerous mentions of technicians arriving on time or even early, completing work efficiently, and providing same-day service. Customers frequently express confidence in the quality of work performed, even under challenging conditions like extreme heat, and many indicate strong loyalty, stating they will use the service again and recommend it to family and friends. The emotional tone is enthusiastic and appreciative, with reviewers describing their experiences as "great," "excellent," "fantastic," and "outstanding." Overall, the reviews convey a sense of trust, reliability, and exceptional customer care that has clearly resonated with clients.
Kyle, TX at a glance
Garner Heating & Air Conditioning Inc has completed 15 jobs in Kyle, TX between May 2024 and June 2024.
The most recent job was on June 7, 2024.
Garner Heating & Air Conditioning Inc has completed 525 jobs in Kyle, TX in the last 12 months. The first job there was in July 2018.
Our Local Reviews by City
- Austin, TX (78)
- Buda, TX (331)
- Canyon Lake, TX (5)
- Creedmoor, TX (4)
- Dale, TX (1)
- Driftwood, TX (29)
- Dripping Springs, TX (26)
- Hays, TX (1)
- Kingsbury, TX (1)
- Kyle, TX (480)
- Lockhart, TX (15)
- Manchaca, TX (9)
- Martindale, TX (14)
- Maxwell, TX (3)
- Mountain City, TX (26)
- New Braunfels, TX (13)
- Niederwald, TX (15)
- San Marcos, TX (157)
- Seguin, TX (3)
- Uhland, TX (2)
- West Lake Hills, TX (1)
- Wimberley, TX (104)
- Woodcreek, TX (4)
Job Locations and Reviews
Service diagnostic found that the condensate drain line has clogged. The secondary drain line is also not level which could cause water to flow back out of the secondary and spill out of the pan. Options for repair were presented to the customer and they chose to have the drain line cleared and to move the drain line so that if water flows into the secondary it will reliably shut down the system. Repairs have been completed and the system is operational.
Replaced the condenser fan motor and cleaned the evaporator coil in place. The system was function checked and was running at the time of departure.
Performed cooling maintenance on one straight cooling system. Checked all electrical, mechanical and performance of the system. Cleared and treated the drain line and washed the outdoor coil. Customer had replaced the filter before my arrival. I did find the high voltage wire nuts at the furnace and at the outdoor condenser were undersized. I replaced them and reset the breaker. No other major issues were found, and the system is operational at this time.
Performed cooling maintenance on one heat pump system. Checked all electrical mechanical and performance of the system. Cleared and treated the drain line and washed the outdoor coil. No other major issues were found, and the system is operational at this time.
Service diagnostic found that the drain line is clogged. Water has backed up and tripped the safety switch shutting down the system. There is a large amount of buildup where the drain line connects to the primary pan. I cleared the drain and the buildup at the connection. I then flow tested the drain with water and treated the drain. The system was running at the time of departure.
Performed AC cool check. Checked electrical, mechanical, safety and performance of the system. The blower wheel is clean. The drain line was cleared and treated; a significant amount of buildup was blown out of the drain line. I showed the customer where to treat the drain, as well as how often, to help with future buildup. Condenser coil clean. Condenser fan motor and contactor are in good condition. Refrigerant charge is within factory specifications and is cooling at 10 degrees of sub cooling. The capacitor for the condenser unit has failed on the herm/compressor terminal and the system is running completely off the start assist kit. Options for repair were presented to the customer and they chose to have the capacitor replaced today. I replaced the capacitor on the condenser unit and function checked the system. The system is running at the time of departure.
Performed diagnostic. I found that the outdoor condenser fan motor is not working. I confirmed there’s 240 volts and the capacitor is within range. I presented my findings to the homeowner, and she chose to have the motor replaced at this time. I rinsed the outdoor unit to ensure the coils were clean. I replaced the motor and cycled power at the thermostat. The system is operating at this time with 8 degrees of subcooling and 15 degrees temperature split.
Performed cooling maintenance on one heat pump system. Checked all electrical, mechanical and performance of the system. Cleared and treated the drain line and washed the outdoor coil. Filter was replaced recently by the homeowner. No major issues were found, and the system is operational at this time.
Performed AC cool check. Checked electrical, mechanical, safety, and performance of the system. The drain line was cleared and treated. The wiring is tight and in good condition. The blower wheel is clean. The condenser fan motor and contactor are in good condition. The refrigerant charge is within factory specifications. The capacitor for the condenser unit is below value. The condenser coil was cleaned. Options for repair were presented to the homeowner and they chose to have the capacitor replaced today. I replaced the capacitor on the condenser unit and function checked the system. The system is running at the time of departure.
Performed the semiannual maintenance on one inverter driven straight electric AC unit. Inspected all Performance, Mechanical and Safety Systems. I went through the system outside and verified all wiring was properly positioned and secured. I noticed the outdoor coil had some dirt and dust build up so I went ahead and proceeded with the regular maintenance of the unit. I washed the outdoor coil out and removed all leaves from the base pan. Ensured the outdoor surge protection device was on and green lit. Flushed and treated the primary drain line as well. Verified everything was working within manufacture’s specifications for operation. Everything is working at this time.
Cool check completed on a horizontal gas system. The indoor capacitor is outside of manufacture specs. The evaporator coil is showing significant signs of rust. The drain line has been cleared and treated. The float switches were checked and are operational. The outdoor condenser coils are clean. The outdoor capacitor is outside of manufacture specs. The condenser fan motor is leaking lubricant. The refrigerant is low on charge. Presented my findings to the homeowner and they have opted to have both capacitors replaced and refrigerant added at this time. Completed all repairs and the system is cooling properly at time of departure.
Sweated out the old compressor. Brazed in new filter dryer upstairs. Brazed in new compressor. Mounted and connected the ICM. Pressure and vacuum tested. Charged with refrigerant to 8 degrees subcooling. System operational at time of departure.
On arrival the customer stated that there was water dripping outside her home from the secondary drain line of her air conditioner. I poured half a gallon of water in the primary drain line to see if it was draining. I confirmed there is a clog in the primary drain line which is causing water to back up and drain out the secondary drain. I cleared the drain clog and tested the line with 2 gallons of water. I then treated the drain line. I ran the system for 15 minutes and confirmed the water was not backing up anymore. No other major issues were found and the system is operational at this time.
Performed cooling maintenance on one straight cool system. Checked electrical, mechanical and performance of the system. Cleared and treated the drain line washed the outdoor coil. I replaced the high-voltage wire nuts at the furnace which were undersized. I also found that the Seal-Tite for the condenser fan motor wiring wasn’t covering the wiring completely. I fixed the Seal-Tite to prevent any water from damaging the electrical wiring. No other major issues were found, and the system is operational at this time.
Performed cooling maintenance on a straight cool system. Checked all electrical mechanical and performance of the system. Cleared and treated the drain line and washed the outdoor coil. Customer supplied filter for replacement. No major issues were found, and the system is operational at this time.