Get the Best HVAC Service
Garner Heating & Air Conditioning offers over 35 years experience in servicing, repairing, and replacing your HVAC system, so let us take that pressure off of you. We'll do the work - you enjoy the comfort. Call 512-392-2000 for all your HVAC replacement, repair and maintenance service near Kyle, TX or contact us online with any questions.
HVAC Replacement Service in Kyle, TX
Like all major appliances in your home, your HVAC system is made up of countless parts all working in concert to provide your home welcoming comfort. Those parts need to be properly maintained and cared for so you always have the warming heat or refreshing cool you need. But who has the time to do that themselves?
If your AC unit is more than 10-15 years old, replacing it could save you money on energy bills and repair costs. Upgrading to a new, energy-efficient system can improve comfort, reduce maintenance, and lower your electricity usage.
When Should You Replace Your HVAC System?
- Your AC needs frequent, costly repairs.
- Your unit is over 10 years old and struggles to cool your home.
- Energy bills have steadily increased despite regular maintenance.
- Your home has uneven temperatures from room to room.
What Size AC Unit Do You Need?
The right AC size depends on your home’s square footage, insulation, and layout. An oversized unit may cool too quickly without removing humidity, while an undersized unit will struggle to keep up. Our HVAC experts perform a full evaluation to recommend the best system for your home.
Expert Air Conditioning Repair in Kyle, TX
If your AC isn’t keeping up with the heat, it might be time for repairs. Common signs your air conditioner needs servicing include:
- Warm air blowing from vents – This could indicate low refrigerant levels or a failing compressor.
- Unusual noises – Grinding, squealing, or rattling sounds could mean parts are loose or worn out.
- High energy bills – If your energy costs are rising, your system may be struggling to run efficiently.
- Frequent cycling – If your AC turns on and off repeatedly, it could be a sign of thermostat issues or restricted airflow.
How Long Does AC Repair Take?
Most AC repairs can be completed within a few hours, depending on the problem. Our team arrives with the tools and parts needed to diagnose and fix issues quickly. If a major repair is needed, we’ll discuss your options and provide transparent pricing before starting any work.
Heating and Cooling Service FAQs
If your air conditioner freezes, follow these steps to get your unit functioning again:
- Turn off the unit from the breaker. This will allow the unit to thaw. FYI, thawing could take an entire day.
- Do not remove the ice by hand to avoid damaging the unit.
- After thawing, dry the coils by turning back on your unit but on the fan setting only. This helps circulate air and dry the coils quickly.
- Turn the AC back on to see if it operates without freezing over.
Homeowners can anticipate paying between $100 - $500 for air conditioner repairs.
A faulty drain pan, loose connections, or worn-out components can lead to costly water damage. Catching minor issues early prevents major headaches down the road.
The cost to replace a heating and cooling system typically ranges from $5,000 to $15,000, depending on factors like the size of the home, system efficiency, and installation requirements.
If it's Garner, It's Guaranteed
We know it can be difficult to bring someone into your home and trust them to do the work right. That's why Garner offers at 100% satisfaction guarantee on all the service we perform. We want you to be certain, before we even step through the door, that you're going to get the right solutions, at the right price, with the right quality.
Give us a call at 512-392-2000 and make us your partner in comfort today. Of course, the best opinion on our work comes from your neighbors. See what they have to say about Garner Heating & Air Conditioning below.
Recent Jobs and Reviews in Kyle, TX
Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting high levels of customer satisfaction and appreciation. Customers consistently express gratitude for the professionalism, punctuality, and expertise demonstrated by the service team. There is a strong recurring theme of technicians being knowledgeable, thorough, and excellent communicators who take time to explain issues, answer questions, and provide helpful advice without applying undue pressure. Many reviewers highlight the courteous and respectful nature of the staff, noting details such as wearing shoe covers, protecting work areas, and leaving spaces clean after completion. Timeliness emerges as another dominant positive trend, with numerous mentions of technicians arriving on time or even early, completing work efficiently, and providing same-day service. Customers frequently express confidence in the quality of work performed, even under challenging conditions like extreme heat, and many indicate strong loyalty, stating they will use the service again and recommend it to family and friends. The emotional tone is enthusiastic and appreciative, with reviewers describing their experiences as "great," "excellent," "fantastic," and "outstanding." Overall, the reviews convey a sense of trust, reliability, and exceptional customer care that has clearly resonated with clients.
Kyle, TX at a glance
Garner Heating & Air Conditioning Inc has completed 15 jobs in Kyle, TX in May 2024.
The most recent job was on May 17, 2024.
Garner Heating & Air Conditioning Inc has completed 525 jobs in Kyle, TX in the last 12 months. The first job there was in July 2018.
Our Local Reviews by City
- Austin, TX (78)
- Buda, TX (331)
- Canyon Lake, TX (5)
- Creedmoor, TX (4)
- Dale, TX (1)
- Driftwood, TX (29)
- Dripping Springs, TX (26)
- Hays, TX (1)
- Kingsbury, TX (1)
- Kyle, TX (480)
- Lockhart, TX (15)
- Manchaca, TX (9)
- Martindale, TX (14)
- Maxwell, TX (3)
- Mountain City, TX (26)
- New Braunfels, TX (13)
- Niederwald, TX (15)
- San Marcos, TX (157)
- Seguin, TX (3)
- Uhland, TX (2)
- West Lake Hills, TX (1)
- Wimberley, TX (104)
- Woodcreek, TX (4)
Job Locations and Reviews
Performed AC cool check. Checked electrical, mechanical, safety, and performance of the system. The air handler and blower wheel are clean. The drain line was cleared and treated. The wiring is tight and in good condition. The condenser fan motor is showing signs of overheating. The contactor is in good condition. The refrigerant charge is within factory specifications. Condenser capacitor is within value. Condenser coil was cleaned. No other major issues were found.
Arrived for a two-system cool check. Upstairs System - Found blower capacitor leaking oil. The condensation line has been cleared and treated. Safety switches checked and are operational. Outdoor condensing coil clean. Capacitor and contactor within range. Refrigerant levels adequate. Condenser fan motor is leaking grease. Downstairs System - Found blower motor leaking grease and showing signs of overheating. The condensation line has been cleared and treated. Safety switches checked and are operational. Outdoor condenser electrical within manufacture specs. Found downstairs refrigerant levels below range. After discussing repair options with the customer, he has chosen to have the upstairs blower motor capacitor replaced. He has also opted to have refrigerant added to the downstairs unit. Lastly, he chose to have the upstairs condenser fan motor replaced. Completed repairs and both systems are operational.
I charged the system with refrigerant to bring it up to factory specifications. 3lbs of R-410A was added. The sub cooling is now 10 degrees. The temperature split is 19 degrees. System was running at the time of departure.
Single system cool check completed on a gas system. The upstairs unit is clean, and the air filter has been changed. The float switch was checked and is working properly. The drain line has been cleared and treated. Outside condensing coils clean. Amp draws within range. All electrical within manufacture specs. Checked temperature differential and it was within range. The system is operating properly at this time.
Single system cool check completed. The indoor furnace was checked for cleanliness and amp draws are within range. The condensation drain line was cleared and treated. The float switch was checked and is operating properly. Outdoor coils have been cleaned. Fan and compressor amps are within range. I did find the capacitor is well below manufacture specs. Also, the refrigerant levels are slightly low giving a 15° temperature split. Inspected the outside system for leaks where oil residue was found and was able to detect a leak coming from liquid line service valve. Presented repair options and the homeowners decided to have the capacitor replaced. Replaced the capacitor and function checked the system. Everything is currently operational.
Single system cool check was performed on a gas system. The furnace is clean with no buildup found. Drain lines cleared and treated. Both float switches checked and are operational. Both air filters have been changed. Outdoor condensing coil clean. All electrical within manufacture specs. Refrigerant level good. No major issues found, and the system is operating properly at this time.
nstalled 5-ton Carrier heat pump system. Installed Ecobee thermostat. Installed plywood overlay for system. Transitioned to existing supply plenum. Rebuilt and insulated primary drain line. Installed SS2 safety float switch. Cleared drain and verified operation. Replaced disconnect and ran both high and low voltage in new Seal-Tite. Installed new UV shield. Installed air purifier. Pressure tested and pulled a vacuum on the copper line set. Weighed in charge to meet manufacturers specifications.
Performed AC cool check. Checked electrical, mechanical, safety, and performance of the system. The drain line was cleared and treated. The air handler and evaporator coil are clean. The blower wheel is also clean. The wiring is tight and in good condition. Condenser coil clean. The condenser fan motor is in good condition. Refrigerant charge is within factory specifications. Surge protection for both sides of the system are operational. No major issues were found. The system was running at the time of departure.
Replaced the indoor evaporator coil. Replaced the inline filter dryer, pressure tested with dry nitrogen and pulled a vacuum on copper line set. Rebuilt condensate drain and added SS2 safety float switch. Cleared and treated the condensate drain. Charged system to factory specs and checked operation of the system. The system is working properly at this time
I rinsed out the outdoor coil, cleared and treated the drain. I checked over the system and discovered the following: the evaporator coil is leaking refrigerant, the condenser fan motor is leaking oil and overamping, and the defrost control board is showing signs of overheating around the central resistors. I brought all of this to the attention of the customer and made her a few options. System is working to the best of its ability at completion of appointment.
I rinsed out the outdoor coil, cleared and treated the drain. I checked over the system and discovered the following: the evaporator coil is leaking refrigerant, the condenser fan motor is leaking oil and overamping, and the defrost control board is showing signs of overheating around the central resistors. I brought all of this to the attention of the customer and made her a few options. System is working to the best of its ability at completion of appointment.
I rinsed out the outdoor coil, cleared and treated the drain. I checked over the system and discovered the following: the evaporator coil is leaking refrigerant, the condenser fan motor is leaking oil and overamping, and the defrost control board is showing signs of overheating around the central resistors. I brought all of this to the attention of the customer and made her a few options. System is working to the best of its ability at completion of appointment.
I rinsed out the outdoor coil, cleared and treated the drain. I checked over the system and discovered the following: the evaporator coil is leaking refrigerant, the condenser fan motor is leaking oil and overamping, and the defrost control board is showing signs of overheating around the central resistors. I brought all of this to the attention of the customer and made her a few options. System is working to the best of its ability at completion of appointment.
Replaced the mini split coil in the living room. Pressure tested with dry nitrogen and pulled a vacuum on copper line set. Charged system to factory specs and teat operation. The system is working properly at this time.
On arrival, the customer informed me that his outdoor fan motor was not running. I performed a diagnostic on the system and found that some of the wires from the motor had hit the fan blade causing them to be cut. I fixed the wire connection and reset the breaker, but the motor was not functioning and also had grease on the shaft. Presented my findings to the customer and they chose to have the motor replaced today and join our maintenance plan. I replaced the motor and cycled power. No other major issues were found. System is operational at this time.