Expert HVAC Service in Mountain City TX
Since 1988, residents of Mountain City, TX have trusted Garner Heating & Air Conditioning to provide professional work and outstanding service for all of their HVAC needs. If you're looking for a provider you can count on, call today!
Your home air conditioner may be running but not cooling in Mountain City, TX because:
- Your thermostat is set to ON rather than AUTO.
- Your air filters are dirty or clogged.
- Your air conditioner’s drain line is clogged.
- Your air conditioner has a refrigerant leak.
If you are encountering one of the first two issues, then it can be an easy fix. If you are encountering one of the last two issues, you will need someone with HVAC knowledge to repair your air conditioner. Give us a call today to have your air conditioner repaired.
The average cost to repair an air conditioner in Mountain City, TX is around $350-$800. However, some things can cause the price to fluctuate, such as:
- The level of the repair.
- The price for any replacement parts.
- The contractor’s hourly fee.
Some repairs can be quite costly, depending on how extensive they are and if they cause further damage to the function of your air conditioner. Maintenance plans are a great way to prevent unexpected and costly repairs since you can spot problems before they become large repairs. To get your air conditioner repaired, contact us today.
It costs about $5,000-$8,000 to install a new furnace and air conditioner in Mountain City, TX. However, some things that can cause the cost to vary are:
- The size of your house.
- The type of HVAC unit you want.
- The contractor’s hourly rate.
Having a new furnace and air conditioner can save you money on your monthly energy bills, as well as increase the overall value of your home. To find out more about getting a new HVAC system installed in your home, call Garner Heating & Air Conditioning today.
When your air conditioner isn’t cooling your home in Mountain City, TX, you should check:
- If your thermostat is set correctly.
- If your air filters are dirty.
- If your air conditioner has a leak.
If your thermostat is already set to cool, check to make sure it is also set to AUTO rather than ON. Additionally, if you find that your air filters are dirty, replace them with new air filters. If your home air conditioner is still not cooling your home, you should call an HVAC technician to repair it. To get your home air conditioner repaired, contact us today.
It costs around $350-$800 to fix and repair your home air conditioner in Mountain City, TX. However, the cost can fluctuate depending on how extensive the repair is, whether replacement parts are required and the contractor’s hourly rate. For instance, having a condenser fan motor replaced can cost up to $700. To learn more about getting your home air conditioner repaired, call Garner Heating & Air Conditioning today.
Yes, air conditioning coils can be repaired if the damage is not too severe. That being said, even though you can repair an evaporator coil, it is typically better to have it replaced rather than repaired. The material that makes up the air conditioning coil can wear out over time through use and the cost to repair it can sometimes outweigh the cost to replace it. If you are thinking about getting your air conditioning coil repaired or replaced, give us a call today.
If you'd like to know what your neighbors in Mountain City, TX think, just check out their reviews below!
Recent Jobs and Reviews in Mountain City, TX
Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting high levels of customer satisfaction and appreciation. Customers consistently express gratitude for the professionalism, punctuality, and expertise demonstrated by the service team. There is a strong recurring theme of technicians being knowledgeable, thorough, and excellent communicators who take time to explain issues, answer questions, and provide helpful advice without applying undue pressure. Many reviewers highlight the courteous and respectful nature of the staff, noting details such as wearing shoe covers, protecting work areas, and leaving spaces clean after completion. Timeliness emerges as another dominant positive trend, with numerous mentions of technicians arriving on time or even early, completing work efficiently, and providing same-day service. Customers frequently express confidence in the quality of work performed, even under challenging conditions like extreme heat, and many indicate strong loyalty, stating they will use the service again and recommend it to family and friends. The emotional tone is enthusiastic and appreciative, with reviewers describing their experiences as "great," "excellent," "fantastic," and "outstanding." Overall, the reviews convey a sense of trust, reliability, and exceptional customer care that has clearly resonated with clients.
Mountain City, TX at a glance
Garner Heating & Air Conditioning Inc has completed 25 jobs in Mountain City, TX between October 2022 and April 2024.
The most recent job was on April 9, 2024.
Garner Heating & Air Conditioning Inc has completed 12 jobs in Mountain City, TX in the last 12 months. The first job there was in July 2018.
Our Local Reviews by City
- Austin, TX (78)
- Buda, TX (331)
- Canyon Lake, TX (5)
- Creedmoor, TX (4)
- Dale, TX (1)
- Driftwood, TX (29)
- Dripping Springs, TX (26)
- Hays, TX (1)
- Kingsbury, TX (1)
- Kyle, TX (480)
- Lockhart, TX (15)
- Manchaca, TX (9)
- Martindale, TX (14)
- Maxwell, TX (3)
- Mountain City, TX (26)
- New Braunfels, TX (13)
- Niederwald, TX (15)
- San Marcos, TX (157)
- Seguin, TX (3)
- Uhland, TX (2)
- West Lake Hills, TX (1)
- Wimberley, TX (104)
- Woodcreek, TX (4)
Job Locations and Reviews
Arrived to diagnose system not cooling. Upon inspection, we found the failed blower capacitor to be the primary issue. Customer approved capacitor replacement. Completed repair and the system is now operational. We did find three other issues: Drain line was partially clogged, there is no safety float switch on the unit and the motor is showing signs of overheating and oil leakage. The homeowner declined further repairs.
Arrived to diagnose system not cooling. Upon inspection, we found the failed blower capacitor to be the primary issue. Customer approved capacitor replacement. Completed repair and the system is now operational. We did find three other issues: Drain line was partially clogged, there is no safety float switch on the unit and the motor is showing signs of overheating and oil leakage. The homeowner declined further repairs.
Arrived to diagnose system not cooling. Upon inspection, we found the failed blower capacitor to be the primary issue. Customer approved capacitor replacement. Completed repair and the system is now operational. We did find three other issues: Drain line was partially clogged, there is no safety float switch on the unit and the motor is showing signs of overheating and oil leakage. The homeowner declined further repairs.
Arrived to diagnose system not cooling. Upon inspection, we found the failed blower capacitor to be the primary issue. Customer approved capacitor replacement. Completed repair and the system is now operational. We did find three other issues: Drain line was partially clogged, there is no safety float switch on the unit and the motor is showing signs of overheating and oil leakage. The homeowner declined further repairs.
Air Conditioning System Repair: Addressing a decline in an AC unit's performance, we identified a damaged condenser coil as the culprit. Our response was swift – we replaced the coil promptly, restoring the system's cooling efficiency. The result is a home that now enjoys cool and refreshing air. Emphasizing the importance of regular coil maintenance, we provided insights to help the client maintain optimal system performance.
Heat Pump Tune-Up: As part of routine seasonal maintenance for a residential client's heat pump system, I performed a detailed tune-up. This involved inspecting and cleaning the outdoor and indoor coils, checking refrigerant levels, lubricating moving parts, and verifying the functionality of the thermostat. I also assessed the defrost cycle to ensure it operates efficiently during colder months. This meticulous tune-up not only enhances the heat pump's efficiency but also prepares it for optimal performance in different weather conditions, providing the homeowner with consistent and reliable heating and cooling.
On arrival, I spoke with the homeowner, and he mentioned that the unit seemed to be running longer in order to heat up the home. At times, it would take longer than an hour to raise the temp a couple degrees. I began my diagnostic by turning on the outdoor heat pump. I noted that only the outdoor condenser fan motor turned on and the compressor remained off. I checked the electrical system and found that the outdoor run capacitor has failed below value across the HERM terminal, which was causing the compressor to not pump refrigerant throughout the indoor fan coil. Spoke with the homeowner and we have decided to replace the run capacitor. Installed new capacitor in the outdoor heat pump system and reset the heat pump. Verified that the compressor and fan motor turned on and operated as designed. While on-site, I performed the semiannual maintenance on the heat pump heating system. Inspected all Performance, Mechanical and Safety Systems. Changed one homeowner supplied 20x20x1
Installed new inverter board on the outdoor heat pump unit. Also installed an ICM493 voltage monitor. Programmed monitor to constantly monitor voltage to ensure proper voltage being applied to system. Tested the heat pump system and inspected all Performance, Mechanical and Safety Systems. Verified everything was operating within manufacture’s specifications for operation.
On arrival, I found the emergency water safety switch tripped due to a restricted drain like. I first blew out the primary line and then inspected the drain system. Found a male threaded fitting loose. Removed fitting and applied new PVC cement and secured fitting into the primary line. I then inspected the primary pan for any water leaks and did not find any cracks inside the pan. I applied a bead of silicone to the pan weep hole plug. Reset the cooling system, blew out the drain and then flushed the line again. Verified everything was operating within manufacture’s specifications for operation. Everything is working at this time.
On arrival, found the emergency water safety switch tripped due to a restricted drain line. Blew out the primary line and went outside to visually confirm the clog was removed. Flushed out line with multiple gallons of water to remove any loose debris from drain. Opened up the indoor air handler and cleaned out the primary drain pan and removed the drain snot that was inside the pan. Used a drain treatment inside the primary pan and line. Reset the cooling system and inspected all Performance, Mechanical and Safety Systems. Everything is working at this time.
Installed new Carrier indoor ductless head in office space. The drain line was so clogged that we were unable to clear it, so we replaced it. Reattached drain and pressure tested the system for extensive leak check. Pulled deep vacuum and weighed in factory charge. System operating at this time.
Performed semiannual maintenance on one cooling system. Inspected all Performance, Mechanical and Safety Systems. Verified everything was operating within the manufacture’s specifications for operation. Indoor system drain line cleared and treated. Cleared drain and removed all water from primary and secondary drain pans. Outside condenser refrigerant pressures are within range and condenser cleaned. No other major issues found and the system was running at time of departure.
Performed the AC tune-up. Cleared and treated drain line. Condenser coil clean. No major issues found.
On arrival, I found the outdoor run capacitor has failed below manufacturer value, which was not allowing the outdoor compressor to turn on and pump refrigerant. Installed new run capacitor and reset the cooling system. Inspected all Performance, Mechanical and Safety Systems. Everything is working at this time.
A/C Maintenance. Performed semiannual maintenance on one cooling system. Inspected all Performance, Mechanical, and Safety Systems. Verified everything was operating within the manufacturer’s specifications for operation. Outside condenser refrigerant pressures are within range and condenser cleaned. Indoor system drain line cleared and treated. Homeowner had already replaced filter before arrival. No major issues were found and system running at time of departure.
Dug up original drain system and then dug a deeper and wider hole for drainage. Blew the drain out to verify the drain was clean and clear and then back filled the hole with pea gravel. Placed some of the original dirt back on top. Verified the cooling system was operational prior to departure. Everything is working at this time.
Performed AC cool check. Checked electrical, mechanical, safety, and performance of the system. No major issues were found. Reme-Halo air purifier is operational. Drain line cleared and treated. Condenser coil cleaned. Media air filter was replaced with customer supplied filter.
Performed the AC tune-up and no major issues were found.
On arrival I met with the homeowner. They mentioned that they had noticed their outdoor unit froze up when running the AC. Said the indoor fan motor was not blowing air throughout the vents. He also said he had changed the capacitor on the fan motor. I tested the old capacitor and found it to still be within range for operation. Upon further inspection, I was noticed to indoor fan relay not closing on a call for the indoor fan. I checked the wiring on the back of that thermostat and noticed the fan wire was not plugged in securely. Tightened down fan wire into thermostat and tested operation. Also stripped back old wire to make sure all wires were securely connected into thermostat. In addition, I stripped back old wire of the low voltage connection inside air handler and verified proper connections and color coding. Tested all cooling operation. Everything is working at this time.
Performed semiannual maintenance on one heat pump cooling system. Inspected all Performance, Mechanical and Safety Systems. Verified everything was operating within the manufacture’s specifications for operation. Both filters inside the wall filter grille were dirty and need to be changed out; homeowner did not have any replacement filters at time of visit.
Performed semiannual maintenance on one heat pump heating system. Inspected all Performance, Mechanical and Safety Systems. Flushed and treated drain line and drain pan. Verified all systems are operating within the manufactures specifications for operation. Fixed the date and time on the thermostat and reset filter reminder and service reminder to updated date.
Performed heat check. Checked electrical, mechanical, safety, and performance of the system. Drain line cleared and treated. Condenser coil clean. Surge protection is operational.
Performed service diagnostic. Diagnostic found that the system was low on refrigerant and that the transformer in the air handler was making a loud buzzing noise. The transformer was still powering the unit. Options for repair were presented to customer and they chose to have the transformer replaced and the system recharged with refrigerant. Repairs were completed. System was function tested. System was running at the time of departure.
Installed new refrigerant line set onto mini split system located in garage. Cut line set to length, installed new flare connections, and tightened to specifications per manufacture. Pulled deep vacuum on the system. Recharged system to manufacture’s guidelines.
Installed new 2-ton Carrier system for the upstairs. Added new drain pan and vibration isolators. Rebuilt drain line with insulation and support. Added new return and supply plenums and sealed all pressure points with air lock. Ran new control wiring for the outside unit and installed new Ecobee Pro thermostat. System operating at this time.