Specializing in Expert HVAC Service in Wimberley, TX
If your home's HVAC system isn't providing the level of comfort you expect, you need to put the professionals of Garner Heating & Air Conditioning on the case. Our highly-trained technicians can diagnose your system to determine if it needs simple maintenance or major repairs, then take all the proper steps to provide solutions that work the right way the first time. Or, if your system has simply reached the end of its effectiveness, we can recommend the right replacement suitably matched to your home and install it to exacting standards. Maintenance, repair, installation - Garner does it all.
If you properly maintain and have your HVAC system inspected on a regular basis the average lifespan of a central air system in your Wimberley TX home is 10-12 years. Proper installation and maintenance can add up to 5 years. Maintenance is key to preventing breakdowns and enjoying every bit of life from your heating and cooling unit.
Call or text Garner AC at 512-392-2000 or contact us online with any questions about how long your AC system should last or to set up an appointment.
The main reasons your air conditioner may be blowing warm air is something is shutting down while the AC fan is operating. Other potential causes could include:
- Thermostat settings
- Electrical problems
- Air filters are dirty
- Potential leaks
- Refrigerant
- Poor air flow with your compressor or outside unit
If you need help when your air conditioner that’s blowing warm air, call or text Garner AC at 512-392-2000 or contact us online to schedule fast service in Wimberley TX.
Yes, Garner AC offers a variety of coupons and discounts for heating, cooling and indoor air quality services in Hays County. Visit the coupons section of our website for the most up-to-date offers.
Some things you should consider when choosing to repair or replace your HVAC system in Wimberly, TX include:
- The age of your HVAC system.
- How well your HVAC system heats and cools.
- If the cost to repair your HVAC is more than half the cost to replace it.
You should also check to see if your energy bills have increased dramatically. As your HVAC system reaches the end of its lifespan it can begin to cost you more on repairs and energy costs. To get your HVAC system repaired or replaced, contact us today.
Yes, HVAC systems need to be serviced in Wimberly, TX. The following can happen if you do not have your HVAC system serviced:
- Your HVAC system will break down more often.
- Your HVAC system will not last as long.
- Your HVAC system will require more repairs.
If you do not have your HVAC system serviced, it will also not be covered under its warranty. Most HVAC warranties require you to have your HVAC system serviced regularly by a licensed HVAC technician in order for them to be valid. Call us today to get your HVAC system serviced.
The average cost to repair your home AC system in Wimberly, TX is about $350-$3500. However, the cost of the repair can vary depending on:
- The type of repair.
- How extensive the repair is.
- The cost of replacement components.
The cost of the repair can also fluctuate due to the time and day of the week the repair is done since most HVAC contractors have higher rates after hours and on the weekends. To get your AC system repaired, give us a call today.
From Heating to Cooling & Everything In-Between
Garner Heating & Air Conditioning is committed to your home's comfort, so we offer a full range of services designed maintain or improve it in every way:
The Right HVAC Service For You
We spend much of our time indoors at home, so its important to make it as comforting and inviting an environment as it can be. That means more than just heating and cooling - it also means clean air free of dust and allergens and proper insulation to keep the inside in and the outside out. At Garner Heating & Air Conditioning, we are dedicated to taking care of every aspect of your home's comfort from the moment air enters your home until the time you breathe it in. Call us today at 512-392-2000 and let us put our more than 30 years experience to work for you.
Of course, we could go on and on, but our best cheerleaders are our happy customers! See what your neighbors in Wimberley, TX have to say about us below:
Recent Jobs and Reviews in Wimberley, TX
Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting high levels of customer satisfaction and appreciation. Customers consistently express gratitude for the professionalism, punctuality, and expertise demonstrated by the service team. There is a strong recurring theme of technicians being knowledgeable, thorough, and excellent communicators who take time to explain issues, answer questions, and provide helpful advice without applying undue pressure. Many reviewers highlight the courteous and respectful nature of the staff, noting details such as wearing shoe covers, protecting work areas, and leaving spaces clean after completion. Timeliness emerges as another dominant positive trend, with numerous mentions of technicians arriving on time or even early, completing work efficiently, and providing same-day service. Customers frequently express confidence in the quality of work performed, even under challenging conditions like extreme heat, and many indicate strong loyalty, stating they will use the service again and recommend it to family and friends. The emotional tone is enthusiastic and appreciative, with reviewers describing their experiences as "great," "excellent," "fantastic," and "outstanding." Overall, the reviews convey a sense of trust, reliability, and exceptional customer care that has clearly resonated with clients.
Wimberley, TX at a glance
Garner Heating & Air Conditioning Inc has completed 20 jobs in Wimberley, TX between April 2022 and August 2022.
The most recent job was on August 15, 2022.
Garner Heating & Air Conditioning Inc has completed 93 jobs in Wimberley, TX in the last 12 months. The first job there was in July 2018.
Our Local Reviews by City
- Austin, TX (78)
- Buda, TX (331)
- Canyon Lake, TX (5)
- Creedmoor, TX (4)
- Dale, TX (1)
- Driftwood, TX (29)
- Dripping Springs, TX (26)
- Hays, TX (1)
- Kingsbury, TX (1)
- Kyle, TX (480)
- Lockhart, TX (15)
- Manchaca, TX (9)
- Martindale, TX (14)
- Maxwell, TX (3)
- Mountain City, TX (26)
- New Braunfels, TX (13)
- Niederwald, TX (15)
- San Marcos, TX (157)
- Seguin, TX (3)
- Uhland, TX (2)
- West Lake Hills, TX (1)
- Wimberley, TX (104)
- Woodcreek, TX (4)
Job Locations and Reviews
Installed new Carrier gas furnace in attic. Moved system location and installed new extended plenum. Installed new drain line and added safety switches. Installed line filter dryer and pressure tested system for extensive leak check. Pulled deep vacuum and installed new Ecobee thermostat. Finished ductwork and benchmarking of the system. Ran control wire and high voltage. Hung and strapped ductwork. System operating at this time.
On arrival, I found that the outdoor Voltage Enhancement System had failed, not allowing the outdoor motor to run. Manually jump-started motor to test operations and did find that the outdoor condenser fan is pulling high amps and there are also multiple heat spots on motor. Replaced the outdoor voltage enhancement system and tested all operations. Everything is working at this time.
After performing the diagnostic, I found that the primary drain line had an obstruction inside the primary drain pan before it goes into the drain line. It was backing up into the secondary drain and tripping the safety float switch. I presented the client with his options, and he chose to have the drain line and primary pan cleared at this time.
Performed the AC tune-up. While performing the inspection I did find that the TXV in the attic has failed. I presented the client with his options, and he chose to have it replaced. Performed the repair and everything is coming on and working at this time. I replaced the TXV inside the air handler. I pressure tested to 350 psi and made sure there were not any leaks. I pulled a vacuum on the refrigerant lines and recharged the system. I have an 11-degree superheat and a 10-degree subcooling.
Performed the AC tune-up. While performing the inspection I found that the Expansion Valve in the attic has failed. I presented the clients with their options, and they chose to have it replaced. Performed the repair by replacing the TXV inside the air handler. I pressure tested up to 400 psi and it held. I also pulled a vacuum on the refrigerant lines and released the refrigerant. Everything is working at this time. I had 8 degrees of superheat and 10 degrees of subcooling at this time.
After performing the diagnostic, I found that the battery cap, starter, and condenser fan motor had failed. I called the landlord to present my findings and repair options. She chose to have all three components replaced to get the system back up and running. She also chose to sign up for our maintenance plan. Repairs completed and system operational.
Performed the AC tune-up and everything is working at this time.
Performed the AC tune-up. While performing the inspection I did find deficiencies with the system. I presented the client with her options, and she chose to have the mandatory repairs done at this time. After performing the repairs everything is working at this time.
Performed the AC tune-up and everything is working at this time.
After performing the diagnostic, I found that ants had completely shorted out the starter. I also found that the battery cap had failed. I presented the client with her options, and she chose to have both repaired today. After performing the repair everything is coming on and working at this time. It is 86 degrees inside the house and 97 degrees outside. I informed the client it will take a few hours before it starts to cool down the house.
Performed the AC tune-up. While performing the inspection I did find deficiencies with the systems. I presented the client with their options, and they are going to call us when they want to get them done.
After performing the diagnostic, I found that the battery cap had completely failed. I presented the client with his options, and he chose to have the battery cap replaced at this time. After performing the repair everything is coming on and working at this time.
Trip 1 - On arrival it was discovered that the system had completely frozen over. Customer was instructed to leave the system off and only run the fan. Will need to reschedule for tomorrow when the system has had a chance to thaw. System was not operational at the time of departure. Trip 2 - Performed service diagnostic. Diagnostic found refrigerant leak at the metering device at the evaporator coil. Options for repair were presented to customer and they chose to replace the evaporator coil. We will order the coil and once received, we will return to complete repairs. Electrical disconnect confirmed in and on. System was running but not cooling at the time of departure. Trip 3 - Performed coil replacement on a Carrier gas furnace in upstairs closet. Removed refrigerant and installed new line filter dryer. Rebuilt drain line and pressure tested system for extensive leak check. Pulled deep vacuum and weighed in factory charge. System operating at this time. Also performed AC tune-u
Performed the AC tune-up and everything is working at this time.
Trip 1 - After performing the diagnostic I found that the blower motor for the master bedroom had completely failed. I informed the client, and he chose to have us replace it. I had to order the motor and we will be back tomorrow to replace it and perform the AC tune-up on the Master Bedroom system. Trip 2 – After talking with the manufacturer, we found that the motor is under warranty. I returned and installed the motor and discounted for the parts warranty. After performing the repair everything is coming on and working. The client decided not to do the maintenance. He also had a $50 off coupon that was added to the ticket.
Performed service diagnostic. Diagnostic found a leak in the evaporator coil; condenser fan motor was leaking grease and starter for the condenser was burnt and pitted. Options for repair were presented to customer and due to the age, the customer would like to speak with our Comfort Consultant regarding replacement options before deciding to move forward with any repairs. System is running but not cooling at the time of departure.
Performed AC cool check on two systems. Checked electrical, mechanical, safety, and performance of the systems. System on guest side of the house (Bryant) has a restriction on the thermal expansion valve. No other major issues were found. Options for repair were presented to customer and they would like to think it over; may choose to replace due to age. Drain lines cleared and treated. Condenser coils cleaned. Disconnects confirmed in and on. System were running at the time of departure.
After performing the diagnostic, I found that the primary drain line for the mini split head upstairs was clogged. I presented the client with his options, and he chose to have it cleared and treated at this time. After performing the repair, I poured 3.5 gallons of water down the primary drain line, and it all drained out without backing up. Everything is working at this time.
After performing the diagnostic, I found that the primary drain line for the mini split head upstairs was clogged. I presented the client with his options, and he chose to have it cleared and treated at this time. After performing the repair, I poured 3.5 gallons of water down the primary drain line, and it all drained out without backing up. Everything is working at this time.