Get the Best HVAC Service
Garner Heating & Air Conditioning offers over 35 years experience in servicing, repairing, and replacing your HVAC system, so let us take that pressure off of you. We'll do the work - you enjoy the comfort. Call 512-392-2000 for all your HVAC replacement, repair and maintenance service near Kyle, TX or contact us online with any questions.
HVAC Replacement Service in Kyle, TX
Like all major appliances in your home, your HVAC system is made up of countless parts all working in concert to provide your home welcoming comfort. Those parts need to be properly maintained and cared for so you always have the warming heat or refreshing cool you need. But who has the time to do that themselves?
If your AC unit is more than 10-15 years old, replacing it could save you money on energy bills and repair costs. Upgrading to a new, energy-efficient system can improve comfort, reduce maintenance, and lower your electricity usage.
When Should You Replace Your HVAC System?
- Your AC needs frequent, costly repairs.
- Your unit is over 10 years old and struggles to cool your home.
- Energy bills have steadily increased despite regular maintenance.
- Your home has uneven temperatures from room to room.
What Size AC Unit Do You Need?
The right AC size depends on your home’s square footage, insulation, and layout. An oversized unit may cool too quickly without removing humidity, while an undersized unit will struggle to keep up. Our HVAC experts perform a full evaluation to recommend the best system for your home.
Expert Air Conditioning Repair in Kyle, TX
If your AC isn’t keeping up with the heat, it might be time for repairs. Common signs your air conditioner needs servicing include:
- Warm air blowing from vents – This could indicate low refrigerant levels or a failing compressor.
- Unusual noises – Grinding, squealing, or rattling sounds could mean parts are loose or worn out.
- High energy bills – If your energy costs are rising, your system may be struggling to run efficiently.
- Frequent cycling – If your AC turns on and off repeatedly, it could be a sign of thermostat issues or restricted airflow.
How Long Does AC Repair Take?
Most AC repairs can be completed within a few hours, depending on the problem. Our team arrives with the tools and parts needed to diagnose and fix issues quickly. If a major repair is needed, we’ll discuss your options and provide transparent pricing before starting any work.
Heating and Cooling Service FAQs
If your air conditioner freezes, follow these steps to get your unit functioning again:
- Turn off the unit from the breaker. This will allow the unit to thaw. FYI, thawing could take an entire day.
- Do not remove the ice by hand to avoid damaging the unit.
- After thawing, dry the coils by turning back on your unit but on the fan setting only. This helps circulate air and dry the coils quickly.
- Turn the AC back on to see if it operates without freezing over.
Homeowners can anticipate paying between $100 - $500 for air conditioner repairs.
A faulty drain pan, loose connections, or worn-out components can lead to costly water damage. Catching minor issues early prevents major headaches down the road.
The cost to replace a heating and cooling system typically ranges from $5,000 to $15,000, depending on factors like the size of the home, system efficiency, and installation requirements.
If it's Garner, It's Guaranteed
We know it can be difficult to bring someone into your home and trust them to do the work right. That's why Garner offers at 100% satisfaction guarantee on all the service we perform. We want you to be certain, before we even step through the door, that you're going to get the right solutions, at the right price, with the right quality.
Give us a call at 512-392-2000 and make us your partner in comfort today. Of course, the best opinion on our work comes from your neighbors. See what they have to say about Garner Heating & Air Conditioning below.
Recent Jobs and Reviews in Kyle, TX
Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting high levels of customer satisfaction and appreciation. Customers consistently express gratitude for the professionalism, punctuality, and expertise demonstrated by the service team. There is a strong recurring theme of technicians being knowledgeable, thorough, and excellent communicators who take time to explain issues, answer questions, and provide helpful advice without applying undue pressure. Many reviewers highlight the courteous and respectful nature of the staff, noting details such as wearing shoe covers, protecting work areas, and leaving spaces clean after completion. Timeliness emerges as another dominant positive trend, with numerous mentions of technicians arriving on time or even early, completing work efficiently, and providing same-day service. Customers frequently express confidence in the quality of work performed, even under challenging conditions like extreme heat, and many indicate strong loyalty, stating they will use the service again and recommend it to family and friends. The emotional tone is enthusiastic and appreciative, with reviewers describing their experiences as "great," "excellent," "fantastic," and "outstanding." Overall, the reviews convey a sense of trust, reliability, and exceptional customer care that has clearly resonated with clients.
Kyle, TX at a glance
Garner Heating & Air Conditioning Inc has completed 15 jobs in Kyle, TX in December 2023.
The most recent job was on December 15, 2023.
Garner Heating & Air Conditioning Inc has completed 525 jobs in Kyle, TX in the last 12 months. The first job there was in July 2018.
Our Local Reviews by City
- Austin, TX (78)
- Buda, TX (331)
- Canyon Lake, TX (5)
- Creedmoor, TX (4)
- Dale, TX (1)
- Driftwood, TX (29)
- Dripping Springs, TX (26)
- Hays, TX (1)
- Kingsbury, TX (1)
- Kyle, TX (480)
- Lockhart, TX (15)
- Manchaca, TX (9)
- Martindale, TX (14)
- Maxwell, TX (3)
- Mountain City, TX (26)
- New Braunfels, TX (13)
- Niederwald, TX (15)
- San Marcos, TX (157)
- Seguin, TX (3)
- Uhland, TX (2)
- West Lake Hills, TX (1)
- Wimberley, TX (104)
- Woodcreek, TX (4)
Job Locations and Reviews
Performed heat check. Checked electrical, mechanical, safety, and performance of the system. Flame ignition achieved and the flame sensor cleaned. The gas pressure was slightly out of range, so I adjusted that today. Filters were also clean. No other major issues were found, and the system was running at time of departure. Gas valves confirmed on. See attached checklist for full tune-up details.
I arrived at the home to find the system on and heating. I spoke to the homeowner about how the system had been operating. I performed a heating tune-up on the system. I made sure to rinse out the condenser coil. During my evaluation I noticed the following: the inside of the air handler is covered in organic growth, the coil has growth on the top and bottom side of it, the blower wheel is dirty, the contactor is pitted and charred and buzzes while engaged, and the condenser fan motor is leaking oil and overamping. System is in working order a completion of appointment.
I arrived at the home to find the system on and heating. I spoke to the homeowner about how the system had been operating. I performed a heating tune-up on the system. I made sure to rinse out the condenser coil. During my evaluation I noticed the following: the inside of the air handler is covered in organic growth, the coil has growth on the top and bottom side of it, the blower wheel is dirty, the contactor is pitted and charred and buzzes while engaged, and the condenser fan motor is leaking oil and overamping. System is in working order a completion of appointment.
I arrived at the home to find the system on and heating. I spoke to the homeowner about how the system had been operating. I performed a heating tune-up on the system. I made sure to rinse out the condenser coil. During my evaluation I noticed the following: the inside of the air handler is covered in organic growth, the coil has growth on the top and bottom side of it, the blower wheel is dirty, the contactor is pitted and charred and buzzes while engaged, and the condenser fan motor is leaking oil and overamping. System is in working order a completion of appointment.
I arrived at the home to find the system on and heating. I spoke to the homeowner about how the system had been operating. I performed a heating tune-up on the system. I made sure to rinse out the condenser coil. During my evaluation I noticed the following: the inside of the air handler is covered in organic growth, the coil has growth on the top and bottom side of it, the blower wheel is dirty, the contactor is pitted and charred and buzzes while engaged, and the condenser fan motor is leaking oil and overamping. System is in working order a completion of appointment.
Performed semiannual maintenance on one gas furnace heating system. Inspected all Performance, Mechanical and Safety Systems. I did run a combustion analysis on the furnace during the maintenance due to the age of the furnace. Found combustion readings to be within range for operation. Did note that the inducer motor bearings are beginning to fail. While the motor was running, I could hear the motor running at a higher pitch. Spoke with Mr. Joe about this concern and he said he wants to let it keep going for the time being. Did verify the system started up prior to departure. Everything is working at this time. See attached checklist for full tune-up details.
Performed heat check. Checked electrical, mechanical, safety, and performance of the system. All heat strips activated. Filters changed with customer supplied filters. During my maintenance, I noticed that the indoor blower motor has a little bit of buildup on it. Brought this to homeowner’s attention and she decided hold off on the blower cleaning until next year. No other major issues were found and system running at time of departure.
Performed heat check. Checked electrical, mechanical, safety, and performance of the system. All heat strips activated. Filter was clean and recently replaced by the homeowner. Outside condenser refrigerant pressures are within range and condenser cleaned. During my maintenance, I noticed the condenser fan motor is showing severe signs of overheating. I presented my findings to the homeowner, but he declined repairs today and would like to revisit during the Spring check. No other major issues were found and system running at time of departure. See attached checklist for full tune-up details.
Performed heat check on a Goodman 90% gas furnace. Checked electrical, mechanical, safety, and performance of the system. Filter was dirty however the customer did not have a replacement. No other major issues were found. See attached checklist for full tune-up details. Flame sensor was cleaned and is in good condition. Drain line was cleared and treated. Inside of the furnace and blower wheel are also clean. Electrical disconnects confirmed in and on system was running at the time of departure.
Performed heat check. Checked electrical, mechanical, safety, and performance of the system. Flame ignition achieved and flame sensor cleaned. Filter was clean as well. No major issues were found and system running at time of departure. Gas valves confirmed on.
I arrived to find the system off and not running. I discovered that the homeowner had run a new thermostat wire to the outdoor unit that needed to be hooked up and that’s why we were called out today. They agreed to my estimate and I got to work. I got the thermostat wire cleaned up and attached both inside and outside. I tested the system and saw the heat strips come on. I also tested the AC and made sure it came on as well. The unit is getting up there in age. By my estimation the system is 10-11 years old. I let them know the average lifespan of these systems and advised that they start saving for a new one.
I arrived to find the system off and not running. I discovered that the homeowner had run a new thermostat wire to the outdoor unit that needed to be hooked up and that’s why we were called out today. They agreed to my estimate and I got to work. I got the thermostat wire cleaned up and attached both inside and outside. I tested the system and saw the heat strips come on. I also tested the AC and made sure it came on as well. The unit is getting up there in age. By my estimation the system is 10-11 years old. I let them know the average lifespan of these systems and advised that they start saving for a new one.
I arrived to find the system off and not running. I discovered that the homeowner had run a new thermostat wire to the outdoor unit that needed to be hooked up and that’s why we were called out today. They agreed to my estimate and I got to work. I got the thermostat wire cleaned up and attached both inside and outside. I tested the system and saw the heat strips come on. I also tested the AC and made sure it came on as well. The unit is getting up there in age. By my estimation the system is 10-11 years old. I let them know the average lifespan of these systems and advised that they start saving for a new one.
I arrived to find the system off and not running. I discovered that the homeowner had run a new thermostat wire to the outdoor unit that needed to be hooked up and that’s why we were called out today. They agreed to my estimate and I got to work. I got the thermostat wire cleaned up and attached both inside and outside. I tested the system and saw the heat strips come on. I also tested the AC and made sure it came on as well. The unit is getting up there in age. By my estimation the system is 10-11 years old. I let them know the average lifespan of these systems and advised that they start saving for a new one.
I arrived at the home to find the system off and not running. I checked over the system and discovered the following: the flue pipe isn’t done up to our standard, the installing company ran a flexible gas line through the cabinet of the furnace, low voltage is being run through installer made holes, the platform wasn’t enlarged to account for the new furnace size, and the reason the system was in failure was due to a loose neutral at the high voltage junction box at the furnace. The homeowner elected to get the system back up and running. I remade new connections inside the junction box. I also checked the AC side of the system and the heating side of the system. He’s wanting to see if he can get in touch with the installation company to rectify the other issues.