Sign up today for our Gold Plan, now only $299/yr! (was $339)

Kyle TX Heating & Air Conditioning Services

Get the Best HVAC Service

Garner Heating & Air Conditioning offers over 35 years experience in servicing, repairing, and replacing your HVAC system, so let us take that pressure off of you. We'll do the work - you enjoy the comfort. Call 512-392-2000 for all your HVAC replacement, repair and maintenance service near Kyle, TX or contact us online with any questions.

Garner heating and air truck driving in kyle texas

HVAC Replacement Service in Kyle, TX

Like all major appliances in your home, your HVAC system is made up of countless parts all working in concert to provide your home welcoming comfort. Those parts need to be properly maintained and cared for so you always have the warming heat or refreshing cool you need. But who has the time to do that themselves?

If your AC unit is more than 10-15 years old, replacing it could save you money on energy bills and repair costs. Upgrading to a new, energy-efficient system can improve comfort, reduce maintenance, and lower your electricity usage.

When Should You Replace Your HVAC System?

  • Your AC needs frequent, costly repairs.
  • Your unit is over 10 years old and struggles to cool your home.
  • Energy bills have steadily increased despite regular maintenance.
  • Your home has uneven temperatures from room to room.

What Size AC Unit Do You Need?

The right AC size depends on your home’s square footage, insulation, and layout. An oversized unit may cool too quickly without removing humidity, while an undersized unit will struggle to keep up. Our HVAC experts perform a full evaluation to recommend the best system for your home.

Expert Air Conditioning Repair in Kyle, TX

If your AC isn’t keeping up with the heat, it might be time for repairs. Common signs your air conditioner needs servicing include:

  • Warm air blowing from vents – This could indicate low refrigerant levels or a failing compressor.
  • Unusual noises – Grinding, squealing, or rattling sounds could mean parts are loose or worn out.
  • High energy bills – If your energy costs are rising, your system may be struggling to run efficiently.
  • Frequent cycling – If your AC turns on and off repeatedly, it could be a sign of thermostat issues or restricted airflow.

How Long Does AC Repair Take?

Most AC repairs can be completed within a few hours, depending on the problem. Our team arrives with the tools and parts needed to diagnose and fix issues quickly. If a major repair is needed, we’ll discuss your options and provide transparent pricing before starting any work.

Heating and Cooling Service FAQs

What should I do if my air conditioner freezes?

If your air conditioner freezes, follow these steps to get your unit functioning again:

  • Turn off the unit from the breaker. This will allow the unit to thaw. FYI, thawing could take an entire day.
  • Do not remove the ice by hand to avoid damaging the unit.
  • After thawing, dry the coils by turning back on your unit but on the fan setting only. This helps circulate air and dry the coils quickly. 
  • Turn the AC back on to see if it operates without freezing over.
What is the average AC repair cost near Kyle TX?

Homeowners can anticipate paying between $100 - $500 for air conditioner repairs. 

Why is my air conditioner leaking water?

A faulty drain pan, loose connections, or worn-out components can lead to costly water damage. Catching minor issues early prevents major headaches down the road.

How much does a new HVAC system cost in Kyle TX?

The cost to replace a heating and cooling system typically ranges from $5,000 to $15,000, depending on factors like the size of the home, system efficiency, and installation requirements.

If it's Garner, It's Guaranteed

We know it can be difficult to bring someone into your home and trust them to do the work right. That's why Garner offers at 100% satisfaction guarantee on all the service we perform. We want you to be certain, before we even step through the door, that you're going to get the right solutions, at the right price, with the right quality.

Give us a call at 512-392-2000 and make us your partner in comfort today. Of course, the best opinion on our work comes from your neighbors. See what they have to say about Garner Heating & Air Conditioning below.

Recent Jobs and Reviews in Kyle, TX

Rated 5.0 out of 5 stars based on 480 customer reviews

Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting high levels of customer satisfaction and appreciation. Customers consistently express gratitude for the professionalism, punctuality, and expertise demonstrated by the service team. There is a strong recurring theme of technicians being knowledgeable, thorough, and excellent communicators who take time to explain issues, answer questions, and provide helpful advice without applying undue pressure. Many reviewers highlight the courteous and respectful nature of the staff, noting details such as wearing shoe covers, protecting work areas, and leaving spaces clean after completion. Timeliness emerges as another dominant positive trend, with numerous mentions of technicians arriving on time or even early, completing work efficiently, and providing same-day service. Customers frequently express confidence in the quality of work performed, even under challenging conditions like extreme heat, and many indicate strong loyalty, stating they will use the service again and recommend it to family and friends. The emotional tone is enthusiastic and appreciative, with reviewers describing their experiences as "great," "excellent," "fantastic," and "outstanding." Overall, the reviews convey a sense of trust, reliability, and exceptional customer care that has clearly resonated with clients.

Kyle, TX at a glance

Garner Heating & Air Conditioning Inc has completed 15 jobs in Kyle, TX between February 2025 and March 2025.

The most recent job was on March 11, 2025.

Garner Heating & Air Conditioning Inc has completed 528 jobs in Kyle, TX in the last 12 months. The first job there was in July 2018.

Job Locations and Reviews

Elijah D.
Elijah D. Checked in
Performed semiannual maintenance on one AC cooling system and inspected all performance, mechanical, and safety systems. Tested and verified everything was operating within manufacturer specifications for operation. Changed out two 12x24x1" air filters provided by the homeowner. Cleaned and cleared the primary condensate line that runs to the upstairs bathroom sink. I cleaned the outdoor condensing coils to help ensure proper heat transfer. No major issues were found. Everything is working at this time.
Kyle, TX 78640
Chey S.
Chey S. Checked in
Performed a single system AC check on a Lennox system. I found the capacitor was below manufacture specs. I presented the homeowner with repair options. Heather chose to replace the capacitor, and I completed the repair. No other major issues were found. The system is cooling properly at this time.
Kyle, TX 78640
Matt F.
Matt F. Checked in
Performed AC cool check and checked the electrical, mechanical, safety, and performance of the system. I cleared the drain line and flow tested the drain with two gallons of water. I also treated the drain line. I replaced the air filter with a customer supplied filter. Condenser coil was cleaned. No major issues were found. The system was running at the completion of service.
Kyle, TX 78640
Omar H.
Omar H. Checked in
Performed AC tune-up on a Carrier infinity system and checked the electrical, mechanical, and performance systems of the unit. Cleared, cleaned, flushed and treated the drain line and cleaned the exterior of the furnace. Washed the outdoor coil and verified the compressor wiring is secure. I did find the blower wheel is dirty. No other major issues were found. The system is operational at this time.
Kyle, TX 78640
Chey S.
Chey S. Checked in
I performed an AC tune-up on a 10 year-old horizontal Carrier system. All electrical and mechanical components are within manufacturer specs. No major issues were found. The system is cooling properly at this time.
Kyle, TX 78640
Omar H.
Omar H. Checked in
Performed AC tune-up on a Carrier straight cooling system and checked the electrical, mechanical and performance systems of the unit. Cleared, cleaned, flushed and treated the drain line and cleaned the exterior of the furnace. Filters were replaced recently and are clean. I washed the outdoor unit and secured the compressor wiring to prevent any electrical rub outs. I did find the outdoor starter was pitted at the contacts. I spoke with the homeowner about repair options, and she agreed to have the starter replaced. I replaced the starter and sprayed residual insecticide around it. I then cycled power at the thermostat. The system is operational at this time.
Kyle, TX 78640
Matt F.
Matt F. Checked in
Performed AC cool check and checked electrical, mechanical, safety, and performance of the system. I cleared and treated the drain line and flow tested the drain with two gallons of water. Condenser coil was cleaned. I found that the blower motor capacitor is below value. I presented options for repair to the customer. The system was running at the completion of service.
Kyle, TX 78640
Ethan D.
Ethan D. Checked in
Installed horizontal Carrier gas furnace 36K BTU. Installed Carrier R-454B evaporator coil with transition to furnace. Installed new return and supply plenums, sealed all connections with mastic and hardcast. Rebuilt condensation drain with SS2 and SS3 safety switches. Cleared drain with CO2 and primed with water. Installed new secondary drain pan. Made new flue pipe connection and installed new gas flex along with sediment trap. Installed Carrier 2.5 ton R-454B condenser. Pressure tested system with nitrogen and pulled vacuum. Installed new disconnect and whip for the outdoor unit. Installed Honeywell T6 thermostat. Tested system operation. The system is running at time of departure.
Kyle, TX 78640
Matt F.
Matt F. Checked in
I performed AC cool check of electrical, mechanical, safety, and performance of the system. I cleared the drain line and flow tested the drain with two gallons of water. The air filter was clean and had been recently replaced by the homeowner. No major issues were found. The system was running at the completion of service.
Kyle, TX 78640
Matt F.
Matt F. Checked in
Performed service diagnostic and found that the condenser fan motor has failed. Options for repair were presented to the homeowner and she chose to have the condenser fan motor replaced and to have surge protection installed on the furnace and condenser unit. I replaced the condenser fan motor with a OEM motor. I installed surge protection on the condenser unit and furnace. I function tested the system and the system is now operational.
Kyle, TX 78640
Omar H.
Omar H. Checked in
On arrival I spoke with the homeowner, and she informed me that she would feel a blast of cold air as the furnace turned on. I first adjusted the “fan control settings” on the Ecobee so that the HVAC system is in control instead of the thermostat. This will allow the furnace to heat up and will give a 90 second delay to the blower to prevent the blast of cold air every time the furnace turns on. I then performed a heater tune-up on a Carrier two stage gas furnace system. Checked the electrical, mechanical and performance systems of the unit. Cleared, cleaned, flushed and treated the drain line and cleaned the exterior of the furnace. The filter was replaced recently and is still in clean condition. I did upsize the high voltage wire nut at the furnace as well. No major issues were found. The system is operational at this time.
Kyle, TX 78640
Ethan D.
Ethan D. Checked in
Installed a Carrier heat pump system. Installed Honeywell thermostat. Installed new extended supply plenum. Installed new return plenum. Sealed all connections with mastic air lock. Rebuilt and insulated primary drain line. Installed SS-2 and SS-3 safety float switches. Pressure tested line set and pulled a vacuum. Replaced disconnect and whip at outdoor condenser. Tested system operation. The system is running at time of departure.
Kyle, TX 78640
Ethan D.
Ethan D. Checked in
Installed a 2-ton Carrier air handler and R-454B heat pump. Installed new plywood overlay. Rebuilt drain line, cleared with CO2 and tested/primed with water. Installed new supply plenum/transition and sealed all connections with mastic. Pressure tested line set with nitrogen and pulled a vacuum. Installed Honeywell T6 thermostat. Installed new disconnect for the outdoor condenser. Added 13oz of R-454B charge according to line set length. Tested heating and cooling operation.
Kyle, TX 78640
Ethan D.
Ethan D. Checked in
Replaced return plenum and ran new 14” flex. Built a custom extended supply plenum and sealed all connections with mastic air lock. Removed satellite plenums and installed sheet metal wyes. Hung all ducting for better air flow. Everything is operational at this time.
Kyle, TX 78640
Matt F.
Matt F. Checked in
Service diagnostic found that the fan relay control board was not consistently running the fan. Further investigation found that the board would run the fan around half the time in auxiliary heating, but most of the time in fan only and not at all in heating with the heat pump. The fan board would also randomly shut down the fan. I traced back the signal voltage to confirm that the board was the issue. Options for repair were presented to the homeowner, and he chose to have the relay board replaced. I replaced the fan relay control board and function tested the system. The fan is now operating normally.
Kyle, TX 78640
Kyle . Buda . San Marcos . Wimberley . Driftwood . Martindale . Manchaca . Lockhart . New Braunfels
Schedule Now Text Us Now
Award Winning Service
  • Google Guaranteed
  • Carrier Authorized Dealer Logo
  • Service Round Table Member Logo
  • Best Or North Hays Logo
  • Nate Certified Technicians Logo
  • National Comfort Institute Inc Logo