Expert HVAC Repair Service in Buda, TX
If you want your Central Texas and Buda, TX home to stay cozy and comfortable, you have to make sure your heating and air conditioning system is running well. Like any major appliance in your home, though, it's important to take care of it, and that means providing proper maintenance and repairs when needed.
Garner Heating & Air Conditioning is your partner for HVAC service in Buda, TX - caring for your system so it remains in top shape, or helping you choose the most efficient and capable solution when it needs to be replaced.
Get the Best Furnace and Air Conditioning Repair Service
Whatever issue you're facing with your HVAC system, know that there is a trusted source for help available to you at any time. To discuss your options, get an estimate or just ask questions about your heater or air conditioner, send us a message online or call 512-392-2000 today.
We'll race over to your home and take care of your HVAC repair issue in no time at all.
Get Your Air Conditioner Fixed Fast
When your air conditioner unit conks out, those unfortunate sounds are followed by a home that is no longer comfortable, especially in the dead heat of the Texas summer. But have no fear. Our experts are masters at diagnosing what's wrong with your system and providing top-notch AC repair to get your home cool and comfy again before you know it.
Residential Air Conditioning Replacement
Is your home's air conditioner getting up there in years? Or maybe you've got one that's just too powerful for your home and it's costing you energy and money? Either way, we can help you choose a new, energy-efficient, advanced air conditioner model that will bring you more modern conveniences and be perfectly-sized to your square footage. Once we've got the right unit chosen, our certified experts will perform your new AC installation with such care and attention to detail you'll hardly know we were there.
HVAC Service FAQs
A few reasons you should replace your air conditioning and heating system rather than repair it in Buda, TX are:
- Your HVAC system is over 10 years old and breaks down often.
- Your energy bills have increased.
- The cost to repair your HVAC system outweighs the cost to replace it.
When your HVAC system becomes ineffective, it will cost you more on energy each month and require multiple repairs. However, if your HVAC system is fairly new, regularly maintained and hasn't required many repairs in the past, you should have it repaired rather than replaced.
An HVAC service should cost around $150-350 in Buda, TX. Having your HVAC serviced is a great way to spot issues before they become more severe. Additionally, regular servicing keeps your HVAC system running more efficiently and extends its service life. The benefits that HVAC maintenance provides greatly outweigh the cost since you save more on energy bills and repair costs.
An HVAC tune-up in Buda, TX typically includes:
- A cleaning of your furnace and AC unit.
- An inspection and lubrication of your furnace and AC unit’s parts.
- Minor repairs.
To get the most out of tuning up your HVAC system, you should have your HVAC system tuned up once before summer and once before winter. Getting your HVAC system tuned up before peak seasons allows your HVAC to run more efficiently and require less repairs.
The average air conditioning repair cost is about $300-$500.
It costs around $7,000-$15,000 to replace a central air conditioning unit in Buda, TX. The cost can vary depending on:
- The size of your home.
- The type of central air conditioning unit you want installed.
- The cost to remove your old AC unit and install the new one.
Another thing that can impact the price of your central air conditioning unit replacement is if your air ducts also need to be replaced. To get your central air conditioning system replaced, call us today.
Your central air conditioner should be checked at least once a year, right before the cooling season in Buda, TX. Getting your central air conditioner cleaned and inspected before your area's peak cooling season will ensure that your central air conditioner is able to run smoothly and efficiently. Additionally, regular servicing can help to extend the service life of your central air conditioner.
Residential Furnace Repair
Got a malfunctioning furnace? Nobody wants to be left out in the cold while inside your home. Our experts are well trained in diagnosing furnace troubles, and once we've discovered the problem we'll have it fixed before you know it. For the most trusted heating repair in Buda, TX - call on Garner.
Go Green with Heat Pump Installation
Two units for the price of one - what a deal! Heat pumps are capable of both heating and cooling your home, so you only have one unit to worry about - all while providing improved energy-efficiency which translates into utility savings. These modern marvels have more than enough power to keep your home at an ideal temperature, so contact our pros today to learn more and schedule your heat pump installation.
Heat Pump Repair Service
When your heat pump goes down, you lose access to your heat and your air conditioning - but both can be quickly restored with our expert heat pump repair services! Our technicians will investigate what's befuddling your unit then deliver a solution with practiced care and unmatched quality.
Indoor Air Quality Solutions for Your Home
How clean is the air you breathe in your home? Believe it or not, indoor air can be many, many times more polluted than the air outside, and when you spend a lot of time indoors trying to avoid the extreme Texas heat, you could be doing your health a disservice. From HVAC UV light installation to air and furnace filters, we can help clean up your air and help your family remain healthy and hearty all year long.
HVAC Service You Can Trust
Your HVAC system is one of your biggest investments. You don't want to leave it's care to just anyone. Garner Heating & Air Conditioning has decades of experience powering our professional technicians, and a family-first focus that means we aren't satisfied until you are.
It doesn't matter if you're looking for someone to handle regular maintenance, interested in upgrading your system or want to explore options to improve your indoor air quality, Garner has you covered. Just drop us a message online or call 512-392-2000 today.
But if you don't want to take our word for it, ask your neighbors! Read below to hear about what others in Buda, TX have been saying about our services.
Recent Jobs and Reviews in Buda, TX
Customers say: The overall sentiment across these reviews is overwhelmingly positive, reflecting high levels of customer satisfaction and appreciation. Customers consistently express gratitude for the professionalism, punctuality, and expertise demonstrated by the service team. There is a strong recurring theme of technicians being knowledgeable, thorough, and excellent communicators who take time to explain issues, answer questions, and provide helpful advice without applying undue pressure. Many reviewers highlight the courteous and respectful nature of the staff, noting details such as wearing shoe covers, protecting work areas, and leaving spaces clean after completion. Timeliness emerges as another dominant positive trend, with numerous mentions of technicians arriving on time or even early, completing work efficiently, and providing same-day service. Customers frequently express confidence in the quality of work performed, even under challenging conditions like extreme heat, and many indicate strong loyalty, stating they will use the service again and recommend it to family and friends. The emotional tone is enthusiastic and appreciative, with reviewers describing their experiences as "great," "excellent," "fantastic," and "outstanding." Overall, the reviews convey a sense of trust, reliability, and exceptional customer care that has clearly resonated with clients.
Buda, TX at a glance
Garner Heating & Air Conditioning Inc has completed 20 jobs in Buda, TX between June 2024 and July 2024.
The most recent job was on July 1, 2024.
Garner Heating & Air Conditioning Inc has completed 250 jobs in Buda, TX in the last 12 months. The first job there was in July 2018.
Our Local Reviews by City
- Austin, TX (78)
- Buda, TX (331)
- Canyon Lake, TX (5)
- Creedmoor, TX (4)
- Dale, TX (1)
- Driftwood, TX (29)
- Dripping Springs, TX (26)
- Hays, TX (1)
- Kingsbury, TX (1)
- Kyle, TX (480)
- Lockhart, TX (15)
- Manchaca, TX (9)
- Martindale, TX (14)
- Maxwell, TX (3)
- Mountain City, TX (26)
- New Braunfels, TX (13)
- Niederwald, TX (15)
- San Marcos, TX (157)
- Seguin, TX (3)
- Uhland, TX (2)
- West Lake Hills, TX (1)
- Wimberley, TX (104)
- Woodcreek, TX (4)
Job Locations and Reviews
Installed new Carrier 4-ton straight ac system. Installed new T6 Pro thermostat. Rebuilt and insulated condensate drain line. Added SS2 and SS3 safety float switches. Cleared drain line with CO2 and ran three gallons of water to ensure proper operation. That was then followed by Viper drain treatment. Installed new filter dryer, pressure tested with dry nitrogen and pulled a vacuum on copper line set. Replace the condenser pad. Replaced the disconnect and ran the low voltage in Seal-Tite. Replaced both supply and return plenums and sealed with a mastic airlock. Charged system to factory spec and performed a benchmark. The system is working properly at time of departure.
I arrived at the home to find the system on and running. I spoke to Bill and Sally about how the unit had been operating. I made sure to clear the drain and rinse out the condenser coil. I checked over the system and discovered that the contactor is pitted and charred and that the capacitor is weak and out of spec. System is working to the best of its ability at this time.
I arrived at the home to find the system on and running. I spoke to Bill and Sally about how the unit had been operating. I made sure to clear the drain and rinse out the condenser coil. I checked over the system and discovered that the contactor is pitted and charred and that the capacitor is weak and out of spec. System is working to the best of its ability at this time.
I arrived at the home to find the system on and running. I spoke to Bill and Sally about how the unit had been operating. I made sure to clear the drain and rinse out the condenser coil. I checked over the system and discovered that the contactor is pitted and charred and that the capacitor is weak and out of spec. System is working to the best of its ability at this time.
I arrived at the home to find the system on and running. I spoke to Bill and Sally about how the unit had been operating. I made sure to clear the drain and rinse out the condenser coil. I checked over the system and discovered that the contactor is pitted and charred and that the capacitor is weak and out of spec. System is working to the best of its ability at this time.
Performed AC cool check. Checked electrical, mechanical, safety, and performance of the system. The drain line was cleared and treated. The air handler, evaporator coil and blower wheel are all clean. The wiring is tight and in good condition. The condenser fan motor and contactor are both in good condition. The capacitor for the condenser unit is within value, and the refrigerant charge is within factory specifications. No major issues were found, and the system is running at the time of departure.
On arrival, I found the thermostat set to the OFF position. Switched it to COOL mode and changed the setpoint down below indoor house temperature. Tested all performance, mechanical and safety systems. Verified everything was operating within manufacture’s specifications for operation. Found no major issues. Everything is working at this time.
Performed semiannual maintenance on one heat pump cooling system. Inspected all Performance, Mechanical and Safety Systems. Tested the outdoor condenser fan motor as it does show signs of overheating; the current electrical amp draw is 1.1 amps out of 1.4amps. I also tested and verified the run capacitor for both the fan motor and the compressor and found them to be within manufacture's range for operation. While out, I went ahead and flushed and treated the primary drain line and the internal drain pan as well. Verified everything was operating within manufacture’s specifications for operation. Everything is working at this time.
Upon arrival the customer stated that the system was not cooling well. Started diagnostic. Found and removed a dirty air filter. Checked the drain and found it to be clogged. Checked refrigerant levels and found them to be low. Also found that the capacitor is below manufacture specs. Presented repair options and the customer has elected to have refrigerant added, have the drained cleared, have the capacitor replaced and sign up for our Silver membership. Completed repairs and cycled the thermostat. The system is cooling properly at this time.
Replaced all of the flex duct to the upstairs and the majority of the flex that feeds the downstairs. Sealed the collars and duct connections. Supported the ductwork for optimal air flow. Cleared, flushed and treated the condensate drain line. Checked operation of the system and it is working properly at this time.
Cool check completed on an up-flow system. Inspected the indoor unit and found it to be in good condition. All components are running properly. The drain line was cleared and treated. The float switch was checked and is operational. The outdoor coils were cleaned. The refrigerant level is within spec. The capacitor is within range. The contractor is original to the system and in rough condition. No other major issues found.
Two system cool check completed. No major issues found with the 6-year-old horizontal system. On the 19-year-old up-flow system, the indoor coil looks good. The capacitor for the blower motor is slightly below manufacture specs. The outside coil was cleaned. The condenser fan motor is leaking lubricant, and the contactor is in poor condition. The refrigerant level is within spec on both units.
I arrived at the home to find the system off. I spoke to the homeowner about how the unit had been operating. I made sure to rinse out the outdoor coil and also clear the drain upstairs. I checked over the system and found everything to be in pretty good shape. I did notice that the disconnect is starting to melt outside and needs to be replaced before it fails. Presented repair options and the customer chose to move forward with replacement of the disconnect. I replaced the disconnect and installed a new 3/4” whip to the condenser. I made sure to silicone the top and sides of the disconnect. We got the power switched on and tested the system; everything is working properly.
I arrived at the home to find the system off. I spoke to the homeowner about how the unit had been operating. I made sure to rinse out the outdoor coil and also clear the drain upstairs. I checked over the system and found everything to be in pretty good shape. I did notice that the disconnect is starting to melt outside and needs to be replaced before it fails. Presented repair options and the customer chose to move forward with replacement of the disconnect. I replaced the disconnect and installed a new 3/4” whip to the condenser. I made sure to silicone the top and sides of the disconnect. We got the power switched on and tested the system; everything is working properly.
I arrived at the home to find the system off. I spoke to the homeowner about how the unit had been operating. I made sure to rinse out the outdoor coil and also clear the drain upstairs. I checked over the system and found everything to be in pretty good shape. I did notice that the disconnect is starting to melt outside and needs to be replaced before it fails. Presented repair options and the customer chose to move forward with replacement of the disconnect. I replaced the disconnect and installed a new 3/4” whip to the condenser. I made sure to silicone the top and sides of the disconnect. We got the power switched on and tested the system; everything is working properly.
I arrived at the home to find the system off. I spoke to the homeowner about how the unit had been operating. I made sure to rinse out the outdoor coil and also clear the drain upstairs. I checked over the system and found everything to be in pretty good shape. I did notice that the disconnect is starting to melt outside and needs to be replaced before it fails. Presented repair options and the customer chose to move forward with replacement of the disconnect. I replaced the disconnect and installed a new 3/4” whip to the condenser. I made sure to silicone the top and sides of the disconnect. We got the power switched on and tested the system; everything is working properly.
Performed semiannual maintenance on one Carrier Infinity cooling system. Inspected all Performance, Mechanical and Safety systems. Verified the ICM493 Voltage Monitor and Power Surge Protection was on and operating as designed. Verified that the drain line was clean and clear flowing into the hall bath sink. Verified everything was operating within manufacture’s specifications for operation. Everything is working at this time.
On arrival, the customer stated that his outdoor unit would run continuously and never shut off. I performed the diagnostic on the system and found the starter at the condenser has failed and is sending a constant 240 V to the compressor and the motor. I also found that the outdoor condenser fan motor is leaking lubricant. I presented my findings and repair options to the homeowner. They chose to have both components replaced at this time. I replaced the outdoor fan motor and the starter and then cycled power at the thermostat. No other major issues were found, and the system is operational at this time.
Performed semiannual maintenance on one heat pump cooling system. Inspected all Performance, Mechanical and Safety Systems. Removed all the leaves from the bottom of condenser, cleaned and washed the outdoor coil, and checked refrigerant charge. Verified all components were operating within manufacture’s specifications. Everything is working at this time.
Cool check completed on a vertical air handler/heat pump. The indoor unit is clean. The air filters were replaced. The drain line was cleared and treated. I tested the float switch, and it is operational. The condenser coils were cleaned. All electrical within manufactures specs. The contactor is showing significant signs of wear and tear. The unit is slightly low on refrigerant. Presented my findings to the homeowner and he has decided to have refrigerant added today. Added refrigerant to get it within manufacture specs. Cycled system and is it currently operational.